Journals / Glokom Katarakt / 2019 / Cilt: 14 - Sayı: 4

Miyopik Refraktif Lazer Cerrahisi Öncesinde ve Sonrasında Aksiyel Göz Uzunluğu Ölçümleri

Axial Eye-Length Measurements Before and After Myopic Laser Refractive Surgery

Pages
207–211
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Aradaki bu uyumsuzluk, miyopik excimer lazer cerrahisi geçirmiş hastalarda klinik olarak hafi f derecede korneal saydamlık azalmasından dolayı cihaz tarafından hatalı AU ölçümleri sonucu olabilir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Bu çalışmamızın amacı, miyopi nedeniyle refraktif lazer tedavisi uygulanan gözlerde aksiyel uzunluk(AU) ölçümleri ile teorik ablasyon derinliği (TAD) arasındaki ilişkiyi değerlendirmektir.
📊
Key Findings & Data:Gereç ve yöntem: Miyopi ve/veya miyop astigmatizma için refraktif lazer cerrahisi geçirmiş 18 hastanın 35 gözüne ait tıbbi kayıtları retrospektif olarak gözden geçirdik.
💡
Conclusion & Impact:Aradaki bu uyumsuzluk, miyopik excimer lazer cerrahisi geçirmiş hastalarda klinik olarak hafi f derecede korneal saydamlık azalmasından dolayı cihaz tarafından hatalı AU ölçümleri sonucu olabilir.
🔬Design:Research Article
📍Scope:18 hasta
⚙️Variables:Domain Parameters

Abstract

Amaç: Bu çalışmamızın amacı, miyopi nedeniyle refraktif lazer tedavisi uygulanan gözlerde aksiyel uzunluk(AU) ölçümleri ile teorik ablasyon derinliği (TAD) arasındaki ilişkiyi değerlendirmektir. Gereç ve yöntem: Miyopi ve/veya miyop astigmatizma için refraktif lazer cerrahisi geçirmiş 18 hastanın 35 gözüne ait tıbbi kayıtları retrospektif olarak gözden geçirdik. AL-Scan (Nidek CO, Gamagori, Japan) cihazını kullanarak AU, ön kamara derinliği (ÖKD) ve santral kornea kalınlığını (SKK) ölçtük. Ölçümler arası farkları çift yönlü t test kullanarak analiz ettik. Bulgular: Hastaların ortalama yaşı 26.3±6.4 yıl idi, ve ortalama refraktif değişim (kornea düzleminde) −3.02±1.83 D idi. Onbir hastanın 21 gözünde laser in situ keratomileusis (LASİK) ve 7 hastanın 14 gözünde fotorefraktif keratektomi (PRK) uygulandı. Ameliyat sonrası AU değerleri ortalama 56.86±34.45 μm kısaldı ve bu fark istatistiksel olarak anlamlı idi (P 0.05). Bunun yanısıra, ΔAU ile TAD arasında ($r^2$ =0.215) ve ΔAL ile ΔCCT arasında zayıf bir korelasyon bulundu fakat TAD ile ΔSKK güçlü bir şekilde korele idi ($r^2$ =0.814). Sonuç: AL-Scan cihazı, TAD ile uyumlu olmayan AU değerleri verdi. Aradaki bu uyumsuzluk, miyopik excimer lazer cerrahisi geçirmiş hastalarda klinik olarak hafi f derecede korneal saydamlık azalmasından dolayı cihaz tarafından hatalı AU ölçümleri sonucu olabilir.

Özet

Purpose: The purpose of the present study was to evaluate the relationship between axial length (AL) measurements and the theoretical ablation depth (TAD) in eyes that had undergone excimer laser treatment for myopia. Material and methods: We retrospectively reviewed the medical records for 35 eyes of 18 patients who had undergone refractive laser surgery for the treatment of myopia and/or myopic astigmatism. We measured AL, anterior chamber depth (ACD) and central corneal thickness (CCT) using AL-Scan (Nidek CO, Gamagori, Japan). We analyzed the differences between the measurements using a two-tailed paired t test. Results: The mean age of the patients was 26.26±6.43 years, and their mean refractive change (at the corneal plan) was -3.02±1.83 in 21 eyes of 11 patients who had undergone laser in situ keratomileusis and 14 eyes of 7 patients who had undergone photorefractive keratectomy. The AL was signifi cantly shortened after laser surgery, the mean difference in AL [ΔAL] was 56.86±34.45 μm;(P 0.05). On the other hand, ΔAL and TAD ($r^2$ =0.215) and ΔAL and ΔCCT ($r^2$ =0.184) were poorly correlated with each other, but TAD and ΔCCT were strongly correlated ($r^2$ =0.814). Conclusion: The AL-Scan device gave AL values that were inconsistent with the TAD. Since the TAD and ΔCCT values were similar and were correlated with each other, this disparity might have resulted from incorrect AL measurements by the device due to a clinically subtle loss of corneal transparency in patients who had undergone myopic excimer laser surgery.

🔖

Cite This Article

YASSA, E. T., ÜNLÜ, C. (2019). Miyopik Refraktif Lazer Cerrahisi Öncesinde ve Sonrasında Aksiyel Göz Uzunluğu Ölçümleri. Glokom Katarakt, Cilt: 14 - Sayı: 4, 207–211. https://ajindex.com/articles/161813

References (13)

  1. Ehlke GL, Krueger RR. Laser vision correction in treating myopia. Asia Pac J Ophthalmol 2016;5:434-7
  2. Tanzer DJ, Brunstetter T, Zeber R, Hofmeister E, Kaupp S, Kelly N, Mirzaoff M, Sray W, Brown M, Schallhorn S. Laser in situ keratomileusis in United States Naval aviators. J Cataract Refract Surg 2013 Jul;39:1047-58
  3. Kaswin G, Rousseau A, Mgarrech M, Barreau E, Labetoulle M. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard. J Cataract Refract Surg 2014;40:593-600
  4. Güler E, Kulak AE, Totan Y, Yuvarlak A, Hepşen İF. Comparison of a new optical biometry with an optical low-coherence refl ectometry for ocular biometry. Cont Lens Anterior Eye 2016; 39:336-41
  5. Yağcı R, Güler E, Kulak AE, Erdoğan BD, Balcı M, Hepşen İF. Repeatability and reproducibility of a new optical biometer in normal and keratoconic eyes. J Cataract Refract Surg 2015;41:171-7
  6. Winkler von Mohrenfels C, Gabler B, Lohmann CP. Optical biometry before and after excimer laser epithelial keratomileusis (LASEK) for myopia. Eur J Ophthalmol 2003;13:257-9
  7. Rosa N, Caposso L, Lanza M, Romano A. Axial eye length evaluation before and after myopic photorefractive keratectomy. J Refract Surg 2005;21:281-7
  8. Chalkiadakis SE, Amariotakis GA, Parikaris EA, Peponis VG. Axial length measurements pre and post laser-assisted in situ keratomileusis using IOL master: a pilot study. Clin Ophthalmol 2010;4:1267-9
  9. Tay E, Li X, Gimbel HV, Kaye G. Assessment of axial length before and after myopic LASIK with the IOLMaster. J Refract Surg 2013;29:838-41
  10. Wang Q, Ding X, Savini G, Chen H, Feng Y, Pan C, Hua Y, Huang J. Anterior chamber depth measurements using Scheimpfl ug imaging and optical coherence tomography: repeatability, reproducibility, and agreement. J Cataract Refract Surg 2015;41:178-85
  11. Jorge J, Rosado J, Diaz-Rey J, González-Méijome J. Central corneal thickness and anterior chamber depth measurement by Sirius Scheimpfl ug tomography and ultrasound. Clin Ophthalmol 2013;7:417-22
  12. Nishimura R, Negishi K, Dogru M, Saki M, Arai H, Toda I, Yamaguchi T, Tsubota K. Effect of age on changes in anterior chamber depth and volume after laser in situ keratomileusis. J Cataract Refract Surg 2009;35:1868-72
  13. Dawson DG, Holley GP, Geroski DH, Waring GO 3rd, Grossniklaus HE, Edelhauser HF. Ex vivo confocal microscopy of human LASIK corneas with histologic and ultrastructural correlation. Ophthalmology 20