Journals / Uluslararası Diş Hekimliği Bilimleri Dergisi / 2026 / Cilt: 12 Sayı: 1

Counterfeit Files in Endodontics: A Systematic Review

Endodontide Sahte Eğeler: Sistematik Bir Derleme

Pages
12–23
Publication Date
2026-04-30
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Overall, counterfeit files consistently exhibited differences from original files across mechanical, metallurgical, and visual assessments.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:ABSTRACT Objective: This systematic review aims to critically evaluate in vitro studies investigating the mechanical, metallurgical, and visual characteristics of counterfeit endodontic files, with the goal of proposing effective approaches to differentiate them from their genuine counterparts.
📊
Key Findings & Data:A systematic literature search was independently conducted by two reviewers in five electronic databases (PubMed, Scopus, Cochrane Library, Web of Science, and Google Scholar) up to August 15, 2025 (PROSPERO CRD420251126483).
💡
Conclusion & Impact:Conclusion: Overall, counterfeit files consistently exhibited differences from original files across mechanical, metallurgical, and visual assessments.
🔬Design:Review & Systematic Survey
📍Scope:2025 Verileri
⚙️Variables:Nikel Titanyum · Döngüsel Yorgunluk · Orijinal Eğeler

Abstract

ABSTRACT Objective: This systematic review aims to critically evaluate in vitro studies investigating the mechanical, metallurgical, and visual characteristics of counterfeit endodontic files, with the goal of proposing effective approaches to differentiate them from their genuine counterparts. A systematic literature search was independently conducted by two reviewers in five electronic databases (PubMed, Scopus, Cochrane Library, Web of Science, and Google Scholar) up to August 15, 2025 (PROSPERO CRD420251126483). Reference lists of eligible studies were screened for additional relevant records, and an AI-assisted search using ChatGPT was performed. The methodological quality of included studies was evaluated using an adapted version of criteria derived from previous in vitro systematic reviews. Out of 728 screened records, 9 studies met the inclusion criteria and were included in this qualitative review. Among the included studies, 3 were assessed as having a low risk of bias, 5 as moderate, and 1 as high. A total of 703 files were evaluated across these studies, with 11 types of original files being compared to their counterfeit counterparts in terms of mechanical, metallurgical, and visual characteristics. Due to methodological differences among the included studies and heterogeneous outcome measures, quantitative analysis could not be performed. Conclusion: Overall, counterfeit files consistently exhibited differences from original files across mechanical, metallurgical, and visual assessments. Our findings indicate that, despite visual similarity to genuine files, counterfeit endodontic instruments exhibit inferior mechanical and metallurgical properties, emphasizing the need for clinician vigilance to prevent procedural complications.

Özet

ÖZ Giriş: Bu sistematik derleme, sahte endodontik eğeleri araştıran in vitro çalışmaların mekanik, metalurjik ve görsel özellikler açısından eleştirel bir biçimde değerlendirilmesini amaçlamakta ve bu eğelerin orijinallerinden ayırt edilmesine yönelik etkili yaklaşımlar önermeyi hedeflemektedir. Sistematik literatür taraması, 15 Ağustos 2025 tarihine kadar beş elektronik veri tabanında (PubMed, Scopus, Cochrane Library, Web of Science ve Google Scholar) iki bağımsız araştırmacı tarafından gerçekleştirilmiştir (PROSPERO CRD420251126483). Uygun bulunan çalışmaların kaynakça listeleri ek kayıtlar açısından taranmış ve ChatGPT aracılığıyla yapay zekâ destekli bir arama da uygulanmıştır. Dahil edilen çalışmaların metodolojik kalitesi, önceki in vitro sistematik derlemelerden uyarlanmış kriterler kullanılarak değerlendirilmiştir. Toplamda taranan 728 çalışmadan 9’u dahil edilme kriterlerini karşılamış ve niteliksel derlemeye alınmıştır. Bu çalışmaların 3’ü düşük, 5’i orta ve 1’i yüksek yanlılık riski taşımaktadır. Dahil edilen çalışmalarda toplam 703 eğe değerlendirilmiş olup, 11 farklı orijinal eğe tipi, mekanik, metalurjik ve görsel özellikler açısından sahte muadilleriyle karşılaştırılmıştır. Dahil edilen çalışmalar arasındaki metodolojik farklılıklar ve sonuç ölçütlerinin heterojenliği nedeniyle nicel analiz yapılamamıştır. Sonuç: Genel olarak, sahte eğeler mekanik, metalurjik ve görsel değerlendirmelerde orijinal eğelerden sistematik olarak farklılık göstermiştir. Bulgularımız, sahte endodontik enstrümanların görsel olarak orijinal ürünlere benzese de, mekanik ve metalurjik açıdan yetersiz özellikler sergilediğini ortaya koymakta ve olası klinik komplikasyonların önlenmesi için klinisyenlerin bu konuda dikkatli olmaları gerektiğini vurgulamaktadır.

🔖

Cite This Article

Ünal, M., Çakıcı, F., Bodur, E. (2026). Counterfeit Files in Endodontics: A Systematic Review. Uluslararası Diş Hekimliği Bilimleri Dergisi, Cilt: 12 Sayı: 1, 12–23. https://doi.org/10.21306/dishekimligi.1795458

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (37)

  1. Martins JNR, Silva EJNL, Marques D, Belladonna F, Simões-Carvalho M, Camacho E, Braz Fernandes FM, Versiani MA. Comparison of design, metallurgy, mechanical performance and shaping ability of replica-like and counterfeit instruments of the ProTaper Next system. Int Endod J. 2021;54:780–792.
  2. Proffitt E. Counterfeit and non-compliant dental devices: the dangers and how to mitigate them. Dent Update. 2016;43:307–312.
  3. Investigation into use of counterfeit and non compliant equipment publication]. [cited - GOV.UK [Internet 22.07.25]. Access: https://www.gov.uk/government/news/investigation into-use-of-counterfeit-and-non-compliant equipment.
  4. Rodrigues CS, Vieira VTL, Antunes HS, De-Deus G, Elias CN, Moreira EJL, Silva EJNL. Mechanical characteristics of counterfeit Reciproc instruments: a call for attention. Int Endod J. 2018;51:556–563.
  5. Martins JNR, Silva EJNL, Marques D, Arantes Oliveira S, Ginjeira A, Caramês J, Fernandes FMB, Versiani MA. Multimethod Assessment of Design, Metallurgical, and Mechanical Characteristics of Original and Counterfeit ProGlider Instruments. Materials. 2022;15:3971.
  6. Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod. 2009;35:1469–1476.
  7. Madytianos B, Liu E, Marshall A, Mahony E, Liu K, Manogaran J, Liu HH, Parashos P, Evans M. A critical evaluation of physical and manufacturing properties of genuine and counterfeit rotary nickel–titanium endodontic instruments. Aust Dent J. 2023;68:179 185.
  8. Unal M: Comparison of Design, Cyclic Fatigue Resistance, and Metallurgical Properties of Original, Replica‐Like, and Counterfeit Nickel‐Titanium Files. Microsc Res Tech. [Internet publication] 2025 Aug [cited 10.08.25] Access: https://analyticalsciencejournals.onlinelibrary.wiley.c om/doi/epdf/10.1002/jemt.70061.
  9. Ertas H, Capar ID, Arslan H, Akan E. Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments. Biomed Eng Online. 2014;13:1–6.
  10. Goncharuk-Khomyn M, Noenko I, Belun V, Biley A. Counterfeit Endodontic Files Features Objectified with Scanning Electronic Microscopy: Comparative Study of SOCO SC Pro Original and Falsified Rotary Instruments. 2023;16:565-573.
  11. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, Shamseer L, Tetzlaff JM, Akl EA, Brennan SE. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. bmj. 2021;372.
  12. De Pedro-Muñoz A, Rico-Romano C, Sánchez-Llobet P, Montiel-Company JM, Mena-Álvarez J. Cyclic Fatigue Resistance of Rotary versus Reciprocating Endodontic Files: A Systematic Review and Meta Analysis. J Clin Med. 2024;13:882.
  13. Savitha S, Sharma S, Kumar V, Chawla A, Vanamail P, Logani A. Effect of body temperature on the cyclic fatigue resistance of the nickel titanium endodontic instruments: A systematic review and meta-analysis of: in vitro: studies. Journal of Conservative Dentistry and Endodontics. 2022;25:338–346.
  14. Ragozzini G, Abu Hasna A, dos Reis FAS, de Moura FB, Campos TMB, Bueno CES, Carvalho CAT, de Martin AS. Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments. Int J Dent. 2024;2024:1–8.
  15. Kaya Mumcu A, Sarı S, Özdemir ZY, Kiraz G, Kurnaz S. Comparing the Shaping Efficiency of Original and Replica-Like Endodontic Instruments: in vitro Study. Türkiye Klinikleri Journal of Dental Sciences. 2025;31:51–58.
  16. dos Reis FAS, Abu Hasna A, Ragozzini G, de Moura FB, Campos TMB, de Martin AS, Carvalho CAT, Bueno CES. Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue. Sci Rep. 2023;13:22956.
  17. de Bastos RS, da Silva TV, Vieira VTL, Silva EJNL. Evaluation of mechanical properties of an original and a replica-like reciprocating instruments. Australian Endodontic Journal. 2024;50:486-492.
  18. Campos GO: In-Depth metallurgical, design, and mechanical analysis of Reciproc Blue and four replica-like endodontic systems. Res Sq. [Internet publication]. 2024 Jan [cited 22.07.25] Access: https://www.researchsquare.com/article/rs 3822398/v1.
  19. Alnoury A. Cyclic fatigue resistance of ProTaper gold and two replicalike rotary systems. An in vitro study. Saudi Endod. J. 2024;14:25–30.
  20. Aydın U, Özdemir M, Çulha E, Baştürk Özer MN, Turan B. Evaluation of Cyclic Fatigue Resistance of Novel Replica‐Like Instruments in Static Test Model. Appl Bionics Biomech. 2024;1:8842478.
  21. Zanza A, Russo P, Reda R, Di Matteo P, Donfrancesco O, Ausiello P, Testarelli L. Mechanical and metallurgical evaluation of 3 different nickel-titanium rotary instruments: an in vitro and in laboratory study. Bioengineering (Basel). 2022;9:221.
  22. Uslu O, Haznedaroglu F, Keskin C. Comparison of mechanical resistance and standardization between original brand and replica-like endodontic systems. Aust. Endod. J. 2023;49:149–158.
  23. Tarragó C, De Pablo OV, Loroño G, Conde A, Perez Alfayate R, Rossi-Fedele G, Jorge V, Estevez R. Cyclic Fatigue Resistance of “Replica-like" and Original Reciprocating Instruments in Single and Double Curvatures. Eur Endod J. 2025;10:237.
  24. Oliveira Lima T, Húngaro Duarte MA, Jovedi Rosa S, Teves Cordova AVI, Jara de Souza PR, Ricci Vivan R, Ferreira da Silva G, Priori Alcalde M. Cyclic and torsional fatigue resistance of two replicalike and original brand reciprocating system. RSBO. 2024;21:241-6.
  25. Alcalde M, Duarte MAH, Silva PAA, Calefi PHS, Silva E, Duque J, Vivan R. Mechanical properties of ProTaper gold, EdgeTaper platinum, flex gold and pro-T rotary systems. Eur Endod J. 2020;5:205.
  26. Martins JNR, Silva EJNL, Marques D, Pereira MR, Vieira VTL, Arantes-Oliveira S, Martins RF, Braz Fernandes F, Versiani M. Design, metallurgical features, and mechanical behaviour of NiTi endodontic instruments from five different heat treated rotary systems. Materials. 2022;15:1009.
  27. Martins JNR, Silva EJNL, Marques D, Arantes Oliveira S, Caramês J, Versiani MA. Comparison of geometric design, metallurgical features and mechanical behavior of ProTaper Gold SX and two replica-like instruments. Rev. Port. Estomatol. Med. Dent. Cir. Maxilofac. 2021;62:1–8.
  28. Martins JNR, Nogueira Leal Silva EJ, Marques D, Ginjeira A, Braz Fernandes FM, De Deus G, Versiani MA. Influence of Kinematics on the Cyclic Fatigue Resistance of Replicalike and Original Brand Rotary Instruments. J Endod. 2020;46:1136–1143.
  29. Martins JNR, Silva EJNL, Marques D, Pereira MR, Ginjeira A, Silva RJC, Braz Fernandes FM, Versiani MA. Mechanical Performance and Metallurgical Features of ProTaper Universal and 6 Replicalike Systems. J Endod. 2020;46:1884–1893.
  30. Martins JNR, Silva E, Marques D, Belladonna F, Simões‐Carvalho M, Vieira VTL, Antunes HS, Braz Fernandes FMB, Versiani MA. Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments. Int Endod J. 2021;54:1623–1637.
  31. Sarıyılmaz Ö, Sarıyılmaz E, Keskin C. Influence of reciprocating NiTi instruments on the accuracy of apex locator integrated endomotors during simultaneous working length determination. Middle Black Sea Journal of Health Science. 2020;6:70–75.
  32. Simão Haddad Filho M, de Mello Lemos E, Costa Pugas C, Palladino Andretta Pupo R, dos Santos M, de Fátima Teixeira da Silva D, Carlos Laureano da Rosa L, Marcelo Ferreira de Medeiros J. Analysis of the cutting and resistance of the original waveone® gold primary endodontic instrument compared to the counterfeit. J Dent. Health Oral Disord Ther. 2024;15:179-188.
  33. Federation FDIWD. FDI policy statement on Evidence-based dentistry: Adopted by the FDI General Assembly, September 2016, Poznan, Poland. Int Dent J. 2017;67:12–13.
  34. Silva EJNL, Vieira VTL, Hecksher F, dos Santos Oliveira MRS, dos Santos Antunes H, Moreira EJL. Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig. 2018;22:2633–2638.
  35. Wycoff RC, Berzins DW. An in vitro comparison of torsional stress properties of three different rotary nickel-titanium files with a similar cross sectional design. J Endod. 2012;38:1118–1120.
  36. Silva EJNL, Peña-Bengoa F, Ajuz NC, Vieira VTL, Martins JNR, Marques D, Pinto R, Rito Pereira M, Braz-Fernandes FM, Versiani MA. Multimethod analysis of large- and low-tapered single file reciprocating instruments: Design, metallurgy, mechanical performance, and irrigation flow. Int Endod J. 2024;57:601–616.
  37. Ruiz-Sánchez C, Faus-Llácer V, Faus-Matoses I, Zubizarreta-Macho Á, Sauro S, Faus-Matoses V. The influence of niti alloy on the cyclic fatigue resistance of endodontic files. J Clin Med. 2020;9:1–15.