Journals / Sakarya Üniversitesi Holistik Sağlık Dergisi / 2025 / Volume: 8 Issue: 3

Pupil and Pupillary Light Reflex

Didem Özdağ(UNIVERSITY OF HEALTH SCIENCES, GULHANE SCHOOL OF NURSING, DEPARTMENT OF NURSING SCIENCE)0009-0001-4598-1514
Bediye Öztaş(UNIVERSITY OF HEALTH SCIENCES)0000-0001-6775-1405
Pages
—
Publication Date
2025-12-29
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This article reviews and synthesizes the relevant literature on pupil evaluation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Neurological and neurosurgical diseases encompass a broad spectrum of conditions that may present with acute or chronic courses, benign or malignant characteristics, diverse clinical manifestations, and prolonged recovery periods.
📊
Key Findings & Data:Various assessment approaches are available for the early diagnosis, treatment planning, and timely intervention of these diseases.
💡
Conclusion & Impact:This article reviews and synthesizes the relevant literature on pupil evaluation.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Neurological Examination · Pupil · Pupillary Light Reflex

Abstract

Neurological and neurosurgical diseases encompass a broad spectrum of conditions that may present with acute or chronic courses, benign or malignant characteristics, diverse clinical manifestations, and prolonged recovery periods. Various assessment approaches are available for the early diagnosis, treatment planning, and timely intervention of these diseases. Several scales and scoring systems are used in their evaluation. One such assessment method is the measurement of the pupil and pupillary light reflex, which provides information about the sympathetic and parasympathetic branches of the autonomic nervous system, offers guidance regarding various neural structures, and enables an inexpensive and simple evaluation of patients’ clinical course. In recent years, technological advancements have enabled the objective measurement of this reflex through portable infrared pupillometry devices, thereby aiming to minimize inter-observer variability. However, due to the high cost of such objective assessment tools, many healthcare institutions may be unable to include them in their inventory. Consequently, pupil evaluation using a light source and pupil gauge, performed by healthcare professionals, remains a simple and practical method. To reduce potential inconsistencies in the evaluation process, it is essential that healthcare personnel possess adequate knowledge and practical experience in pupil assessment. This article reviews and synthesizes the relevant literature on pupil evaluation.

🔖

Cite This Article

Özdağ, D., Öztaş, B. (2025). Pupil and Pupillary Light Reflex. Sakarya Üniversitesi Holistik Sağlık Dergisi, Volume: 8 Issue: 3. https://doi.org/10.54803/sauhsd.1767753

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (54)

  1. Bae KS, Roh YS. Training needs analysis of Korean nurses' neurological assessment competency. Nurs Health Sci. 2020;22(1):99-107. doi:10.1111/nhs.12654
  2. Sepit D. Bilinç durumunun değerlendirilmesi ve glasgow koma skalası. Hemşirelikte Eğitim ve Araştırma Dergisi. 2005;2(1):12-6.
  3. Bremner FD. Pupil assessment in optic nerve disorders. Eye (Lond). 2004;18(11):1175-81. doi:10.1038/sj.eye.6701560
  4. Smith J, Flower O, Tracey A, Johnson P. A comparison of manual pupil examination versus an automated pupillometer in a specialised neurosciences intensive care unit. Aust Crit Care. 2020;33(2):162-6. doi:10.1016/j.aucc.2019.04.005
  5. Chen JW, Gombart ZJ, Rogers S, Gardiner SK, Cecil S, Bullock RM. Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the Neurological Pupil index. Surg Neurol Int. 2011;2:82. doi:10.4103/2152-7806.82248
  6. Couret D, Boumaza D, Grisotto C, Triglia T, Pellegrini L, Ocquidant P, et al. Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study. Crit Care. 2016;20:99. doi:10.1186/s13054-016-1239-z
  7. Mitschang D, Sydorenko V, Kühlwein D, Beynon C, Younsi A, Krieg SM, et al. Quantitative pupillometry as a sensitive biomarker for detecting subtle neurological impairment in mild traumatic brain injury - a pilot study. Neurol Sci. 2025;46(10):5243-51. doi:10.1007/s10072-025-08405-2
  8. Martínez-Ricarte F, Castro A, Poca MA, Sahuquillo J, Expósito L, Arribas B, et al. Infrared pupillometry: basic principles and their application in the non-invasive monitoring of neurocritical patients. Neurologia. 2013;28(1):41-51. doi:10.1016/j.nrl.2010.07.028
  9. Cortes MX, Siaron KB, Nadim HT, Ahmed KM, Romito JW. Neurological pupil index as an indicator of irreversible cerebral edema: A case series. J Neurosci Nurs. 2021;53(3):145-8. doi:10.1097/JNN.0000000000000584
  10. Bogucki A, John I, Zinkiewicz Ł, Jachura M, Jaworski D, Suwała K, et al. Machine learning approach for ambient-light-corrected parameters and the Pupil Reactivity (PuRe) score in smartphone-based pupillometry. Front Neurol. 2024;15:1363190. doi:10.3389/fneur.2024.1363190
  11. Akyüz G, Akdeniz Leblebicier M. Otonom sinir sistemi anatomisi ve değerlendirilmesi. Turk J Phys Med Rehabil. 2012;58(1):1-5.
  12. Memetoğlu ME. Gözler beynin aynasıdır: pupilometri ve psikolojideki uygulamaları. Türkiye Bütüncül Psikoterapi Dergisi. 2022;5(10):1-8.
  13. Kerr RG, Bacon AM, Baker LL, Gehrke JS, Hahn KD, Lillegraven CL, et al. Underestimation of pupil size by critical care and neurosurgical nurses. Am J Crit Care. 2016;25(3):213-9. doi:10.4037/ajcc2016554
  14. Ong C, Hutch M, Smirnakis S. The effect of ambient light conditions on quantitative pupillometry. Neurocrit Care. 2019;30(2):316-21. doi:10.1007/s12028-018-0607-8
  15. Kim TJ, Park SH, Jeong HB, Ha EJ, Cho WS, Kang HS, et al. Neurological Pupil Index as an indicator of neurological worsening in large hemispheric strokes. Neurocrit Care. 2020;33(2):575-81. doi:10.1007/s12028-020-00936-0
  16. Kotani J, Nakao H, Yamada I, Miyawaki A, Mambo N, Ono Y. A novel method for measuring the pupil diameter and pupillary light reflex of healthy volunteers and patients with intracranial lesions using a newly developed pupilometer. Front Med (Lausanne). 2021;8:598791. doi:10.3389/fmed.2021.598791
  17. Marshall M, Deo R, Childs C, Ali A. Feasibility and variability of automated pupillometry among stroke patients and healthy participants: Potential implications for clinical practice. J Neurosci Nurs. 2019;51(2):84-8. doi:10.1097/JNN.0000000000000416
  18. Kebapcı A, Topçu S. Interrater reliability in pupillary assessment among intensive care nurses. Intensive Crit Care Nurs. 2020;58:102801. doi:10.1016/j.iccn.2020.102801
  19. Nyholm B, Grand J, Obling LER, Hassager C, Møller JE, Schmidt H, et al. Validating quantitative pupillometry thresholds for neuroprognostication after out-of-hospital cardiac arrest: A predefined substudy of the Blood Pressure and Oxygenations Targets After Cardiac Arrest (BOX)-trial. Intensive Care Med. 2024;50(9):1484-95. doi:10.1007/s00134-024-07574-6
  20. Guillon M, Dumbleton K, Theodoratos P, Gobbe M, Wooley CB, Moody K. The effects of age, refractive status, and luminance on pupil size. Optom Vis Sci. 2016;93(9):1093-100. doi:10.1097/OPX.0000000000000893
  21. Al-Obaidi S, Atem F, Stutzman SE, Aiyagari V, Olson DM. Investigating the association between eye colour and the Neurological Pupil index. Aust Crit Care. 2020;33(5):436-40. doi:10.1016/j.aucc.2019.10.001
  22. Yoo YJ, Yang HK, Hwang JM. Efficacy of digital pupillometry for diagnosis of Horner syndrome. PLoS One. 2017;12(6):e0178361. doi:10.1371/journal.pone.0178361
  23. Cleveland Clinic. Pupil of the eye. Accessed December 29, 2024. Available from: https://my.clevelandclinic.org/health/body/24317-pupil-of-the-eye
  24. Bakbak B, Gedik Ş. Anizokori. Turk J Ophthalmol. 2012;42(Suppl 14):68-72. doi:10.4274/tjo.42.s14
  25. Disse LR, Bockisch CJ, Weber KP, Fierz FC. Differentiation of Horner syndrome and physiological anisocoria by automated pupillometry. J Neuroophthalmol. 2024;45(3):327-32. doi:10.1097/WNO.0000000000002262
  26. Maxin AJ, Whelan BM, Levitt MR, McGrath LB, Harmon KG. Smartphone-based pupillometry using machine learning for the diagnosis of sports-related concussion. Diagnostics (Basel). 2024;14(23):2723. doi:10.3390/diagnostics14232723
  27. Pinheiro HM, da Costa RM. Pupillary light reflex as a diagnostic aid from computational viewpoint: A systematic literature review. J Biomed Inform. 2021;117:103757. doi:10.1016/j.jbi.2021.103757
  28. Chiou PY, Chien CY, Lai YH, Chun CF. The effect evaluation of advanced penlight. PLoS One. 2018;13(11):e0205978. doi:10.1371/journal.pone.0205978
  29. Larson MD, Behrends M. Portable infrared pupillometry: a review. Anesth Analg. 2015;120(6):1242-1253. doi:10.1213/ANE.0000000000000314
  30. Bremner FD, Smith SE. Pupil abnormalities in selected autonomic neuropathies. J Neuroophthalmol. 2006;26(3):209-219. doi:10.1097/01.wno.0000235564.50518.1b
  31. Kramer CL, Rabinstein AA, Wijdicks EF, Hocker SE. Neurologist versus machine: is the pupillometer better than the naked eye in detecting pupillary reactivity. Neurocrit Care. 2014;21(2):309-11. doi:10.1007/s12028-014-9988-5
  32. Omburo L, Stutzman S, Supnet C, Choate M, Olson DM. High variance in pupillary examination findings among postanesthesia care unit nurses. J Perianesth Nurs. 2017;32(3):219-24. doi:10.1016/j.jopan.2015.05.117
  33. Holmskär S, Öhrn M, Furudahl M, Kesti J, Pansell J. Is quantitative pupillometry affected by ambient light? A prospective crossover study. J Clin Monit Comput. 2025;39(5):975-86. doi:10.1007/s10877- 025-01293-z
  34. Anderson M, Elmer J, Shutter L, Puccio A, Alexander S. Integrating quantitative pupillometry into regular care in a neurotrauma intensive care unit. J Neurosci Nurs. 2018;50(1):30-6. doi:10.1097/JNN.0000000000000333
  35. Riker RR, Sawyer ME, Fischman VG, May T, Lord C, Eldridge A, et al. Neurological Pupil Index and pupillary light reflex by pupillometry predict outcome early after cardiac arrest. Neurocrit Care. 2020;32(1):152-61. doi:10.1007/s12028-019-00717-4
  36. Veerapaneni D, Sakthiyendran NA, Kim SY, Nguyen C, Daneshmand A, Abdalkader M, et al. Pupil abnormality frequency in the first 72 hours improves IMPACT score in traumatic brain injury. Preprint. medRxiv. 2024;2024.11.23.24317826. Published 2024 Nov 26. doi:10.1101/2024.11.23.24317826
  37. Wildemeersch D, Baeten M, Peeters N, Saldien V, Vercauteren M, Hans G. Pupillary dilation reflex and pupillary pain index evaluation during general anaesthesia: a pilot study. Rom J Anaesth Intensive Care. 2018;25(1):19-23. doi:10.21454/rjaic.7518.251.wil
  38. Lussier, BL, Olson, DM & Aiyagari, V. Nörokritik bakımda otomatik pupillometri: araştırma ve uygulama. Curr Neurol Neurosci Rep. 2019;19(71). doi:10.1007/s11910-019-0994-z
  39. Hall CA, Chilcott RP. Eyeing up the future of the pupillary light reflex in neurodiagnostics. Diagnostics (Basel). 2018;8(1):19. doi:10.3390/diagnostics8010019
  40. Sulutvedt U, Mannix TK, Laeng B. Gaze and the eye pupil adjust to imagined size and distance. Cogn Sci. 2018;42(8):3159-76. doi:10.1111/cogs.12684
  41. Pedrotti A, Mirzaei M, Tedesco A, Chardonnet J, Marienne F, Benedetto S, et al. Automatic stress classification with pupil diameter analysis. Int J Hum Comput Interact. 2014;30(3):220-36. doi:10.1080/10447318.2013.848320
  42. Sharma S, Baskaran M, Rukmini AV, Nongpiur ME, Htoon H, Cheng CY, et al. Factors influencing the pupillary light reflex in healthy individuals. Graefes Arch Clin Exp Ophthalmol. 2016;254(7):1353-9. doi:10.1007/s00417-016-3311-4
  43. Bergamin O, Schoetzau A, Sugimoto K, Zulauf M. The influence of iris color on the pupillary light reflex. Graefes Arch Clin Exp Ophthalmol. 1998;236(8):567-70. doi:10.1007/s004170050122
  44. Bradley JC, Bentley KC, Mughal AI, Bodhireddy H, Young RS, Brown SM. The effect of gender and iris color on the dark-adapted pupil diameter. J Ocul Pharmacol Ther. 2010;26(4):335-40. doi:10.1089/jop.2010.0061
  45. Belliveau AP, Somani AN, Dossani RH. Pupillary light reflex. In: StatPearls. Treasure Island (FL): StatPearls Publishing; 2023.
  46. McDougal DH, Gamlin PD. Autonomic control of the eye. Compr Physiol. 2015;5(1):439-73. doi:10.1002/cphy.c140014
  47. Tyukhova Y, Waters C. Subjective and pupil responses to discomfort glare from small, high-luminance light sources. Light Res Technol. 2018;0:1-20. doi:10.1177/1477153518772000
  48. Van Rij J, Hendriks P, Van Rijn H, Baayen RH, Wood SN. Analyzing the time course of pupillometric data. Trends Hear. 2019;23:1-22. doi:10.1177/2331216519832483
  49. Yılmaz R, Kocadağ G, Arıcan Ş, Özdemir M, Reisli R, Tuncer Uzun S. Evaluation of pupil diameter for pain assessment in interventional headache management. Agri. 2023;35(1):22-7. doi:10.14744/agri.2022.37880
  50. Vinclair M, Schilte C, Roudaud F, Lavolaine J, Francony G, Bouzat P, et al. Using pupillary pain index to assess nociception in sedated critically ill patients. Anesth Analg. 2019;129(6):1540-6. doi:10.1213/ANE.0000000000004173
  51. Knaggs RD, Crighton IM, Cobby TF, Fletcher AJP, Hobbs GJ. The pupillary effects of intravenous morphine, codeine, and tramadol in volunteers. Anesth Analg. 2004;99(1):108-12. doi:10.1213/01.ANE.0000116924.16535.BA
  52. Chen JW, Vakil-Gilani K, Williamson KL, Cecil S. Infrared pupillometry, the Neurological Pupil index and unilateral pupillary dilation after traumatic brain injury: implications for treatment paradigms. Springerplus. 2014;3:548. doi:10.1186/2193-1801-3-548
  53. Kale N, Özerden M, Karagöz Sakallı N, Kırbaş D. Migren ve pupil disfonksiyonu, epizodik anizokori ile prezante olan bir baş ağrısı olgusu. Düşünen Adam. 2012;25:179-82. doi:10.5350/DAJPN2012250211
  54. Aoun SG, Welch BG, Cortes M, Stutzman SE, MacAllister MC, El Ahmadieh TY, et al. Objective pupillometry as an adjunct to prediction and assessment for oculomotor nerve injury and recovery: Potential for practical applications. World Neurosurg. 2019;121:e475-e480. doi:10.1016/j.wneu.2018.09.140