Journals / Recep Tayyip Erdoğan Üniversitesi Fen ve Mühendislik Bilimleri Dergisi / 2021 / Cilt: 2 Sayı: 2

Effect of Damping Ratios on the Seismic Behavior of a Historical Masonry Guesthouse Building

Ali Fuat Genç(KARADENIZ TECHNICAL UNIVERSITY)0000-0002-2492-4019
Esin Ertürk(KARADENIZ TECHNICAL UNIVERSITY)0000-0003-4053-0877
Ahmet Can Altunışık(KARADENİZ TEKNİK ÜNİVERSİTESİ)0000-0002-2638-2903
Murat Günaydın(KARADENIZ TECHNICAL UNIVERSITY)0000-0002-8549-2985
Fatih Yesevi Okur(KARADENIZ TECHNICAL UNIVERSITY)0000-0003-2402-144X
Pages
60–71
Publication Date
2021-12-31
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The dynamic parameters obtained depending on the existing structural properties, material properties, boundary and damage condition are quite effective on the behavior of the structures under the effect of dynamic loads.
📊
Key Findings & Data:Linear time history analyses were performed for three different damping ratios as 2%, 5%, and 10%.
💡
Conclusion & Impact:It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Damping ratios · Historical masonry structures · Finite element method

Abstract

The dynamic parameters obtained depending on the existing structural properties, material properties, boundary and damage condition are quite effective on the behavior of the structures under the effect of dynamic loads. These dynamic parameters have characteristic features for each structure. In this study, the effect of damping ratio, which is one of the dynamic characteristics, on the seismic behavior of historical structures was studied. For this aim, historical masonry Guesthouse Building belong to the Church of Santa Maria was selected to examined. Linear time history analyses were performed for three different damping ratios as 2%, 5%, and 10%. The horizontal component of Erzincan Earthquake (1992) was used in linear time history analyses. The maximum displacement, principal stress and strain values obtained from performed linear time history analyses for different damping ratios were compared. It is observed that, displacement, stress and strain values increase as the damping ratio decrease when the results are examined. It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake. Therefore, the damping ratios should be obtained with experimental tests before the numerical evaluation of seismic behavior.

Özet

The dynamic parameters obtained depending on the existing structural properties, material properties, boundary and damage condition are quite effective on the behavior of the structures under the effect of dynamic loads. These dynamic parameters have characteristic features for each structure. In this study, the effect of damping ratio, which is one of the dynamic characteristics, on the seismic behavior of historical structures was studied. For this aim, historical masonry Guesthouse Building belong to the Church of Santa Maria was selected to examined. Linear time history analyses were performed for three different damping ratios as 2%, 5%, and 10%. The horizontal component of Erzincan Earthquake (1992) was used in linear time history analyses. The maximum displacement, principal stress and strain values obtained from performed linear time history analyses for different damping ratios were compared. It is observed that, displacement, stress and strain values increase as the damping ratio decrease when the results are examined. It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake. Therefore, the damping ratios should be obtained with experimental tests before the numerical evaluation of seismic behavior.

🔖

Cite This Article

Genç, A. F., Ertürk, E., Altunışık, A. C., Günaydın, M., Okur, F. Y. (2021). Effect of Damping Ratios on the Seismic Behavior of a Historical Masonry Guesthouse Building. Recep Tayyip Erdoğan Üniversitesi Fen ve Mühendislik Bilimleri Dergisi, Cilt: 2 Sayı: 2, 60–71. https://doi.org/10.53501/rteufemud.1019237

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Abaqus (2016). Dassault systémes simulia corp. Providence: Rhode Island, USA.
  2. Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2017). An investigation of the seismic behavior of an ancient masonry bastion using non-destructive and numerical methods, Experimental Mechanics, 57, 2, 245-259.
  3. Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2016). Non-destructive testing of an ancient masonry bastion, Journal of Cultural Heritage, 22, 1049-1054.
  4. Altunışık, A.C., Genç, A.F., Günaydin, M., Adanur, S. and Okur, F.Y. (2018). Ambient vibration-based system ıdentification of a medieval masonry bastion for health assessment using nonlinear analyses, International Journal of Nonlinear Sciences & Numerical Simulation, 19, 2, 107-124.
  5. Benedetti, D., Carydis, P. and Pezzoli, P. (1998). Shaking table tests on 24 simple masonry buildings, Earthquake Engineering and Structural Dynamics, 27, 1, 67-90.
  6. Gentile, C. and Saisi, A. (2007). Ambient vibration testing of historic masonry towers for structural identification and damage assessment, Construction and Building Materials, 21, 6, 1311-1321.
  7. Juhásová, E., Sofronie, R. and Bairrão, R. (2008). Stone masonry in historical buildings-ways to increase their resistance and durability, Engineering Structures, 30, 8, 2194-2205.
  8. Mazzon, N, Valluzzi, M.R., Aoki, T., Garbin, E., De Canio, G., Ranieri, N. and Modena, C. (2009). Shaking table tests on two multi-leaf stone masonry buildings, In: Proceeding of 11th Canadian Masonry Symposium, May 31st - June 3rd, Toronto, Canada.
  9. Toker, S. and Ünay, A.İ. (2004) Mathematical modeling and finite element analysis of masonry arch bridges, Gazi University Journal of Science, 17, 2, 129-139.
  10. Votsis, R.A., Kyriakides, N., Chrysostomou, C.Z., Tantele, E. and Demetriou, T. (2012). Ambient vibration testing of two masonry monuments in Cyprus, Soil Dynamics and Earthquake Engineering, 43, 58-68.