Journals / KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi / 2026 / Cilt: 7 Sayı: 1

Investigation of the Effect of an Automatic Distance-Adjusted Infrared Prototype Operating According to Skin Temperature on Individuals with Chronic Back Pain: A Pilot Study

Cilt Isısına Göre Otomatik Çalışan Mesafe Ayarlı Enfraruj Prototipinin Kronik Bel Ağrılı Bireylerde Etkisinin İncelenmesi: Pilot Çalışma

Mustafa Savaş Torlak(KTO KARATAY ÜNİVERSİTESİ)0000-0002-8084-6203
Saim Ervural(KTO KARATAY ÜNİVERSİTESİ)0000-0003-4104-1928
Burcu Dursun(KTO KARATAY ÜNİVERSİTESİ)0000-0003-0645-3820
Pages
—
Publication Date
2026-07-20
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Furthermore, the prototype was found to be superior to the conventional infrared device in terms of skin temperature control and energy consumption.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to investigate the effect of a skin temperature-controlled and distance-adjusted infrared prototype on individuals with chronic low back pain.
📊
Key Findings & Data:Participants were randomly divided into control (n=10) and experimental (n=10) groups.
💡
Conclusion & Impact:Furthermore, the prototype was found to be superior to the conventional infrared device in terms of skin temperature control and energy consumption.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Enfraruj · Kronik Ağrı · Fizik tedavi Modaliteleri

Abstract

Objective: The aim of this study was to investigate the effect of a skin temperature-controlled and distance-adjusted infrared prototype on individuals with chronic low back pain. Methods: Twenty individuals with chronic low back pain were included in the study. Participants were randomly divided into control (n=10) and experimental (n=10) groups. While heat therapy with a conventional infrared device was applied to the control group for 20 minutes, 3 times a week for 4 weeks, heat therapy with the prototype device was applied to the experimental group for the same duration. Pain intensity was evaluated using the Visual Analog Scale (VAS), and quality of life was evaluated using the SF-36 survey at the beginning and end of the study. Additionally, skin temperatures of the treatment area were measured with a laser thermometer at the end of the treatment, and energy consumption of the infrared devices was measured with a wattmeter during the treatment. Results: At the end of the study, there was a significant difference in VAS and SF-36 values in both groups (p 0.05). Mean skin temperature values were measured as 41.3 °C in the conventional infrared device and 39.3 °C in the prototype device. It was determined that the prototype provided approximately 33% energy savings compared to the conventional infrared device at the end of the study. Conclusion: In this pilot study, it was observed that the prototype had a positive effect on pain compared to the conventional infrared device, but there was no difference in SF-36 values. Furthermore, the prototype was found to be superior to the conventional infrared device in terms of skin temperature control and energy consumption.

Özet

Amaç: Cilt ısısına göre çalışan mesafe ayarlı enfraruj prototipinin kronik bel ağrılı bireylerde etkisinin incelenmesi amaçlanmıştır. Yöntem: Çalışmaya 20 kronik bel ağrısı olan birey dahil edilmiştir. Katılımcılar randomize şekilde kontrol (n=10) ve deney (n=10) gruplarına ayrılmıştır. Kontrol grubundaki katılımcılara 4 hafta boyunca haftada 3 kez 20 dakika klasik infraruj cihazı ile sıcak tedavisi uygulanırken, deney grubuna aynı sürede prototip cihazla sıcak tedavisi uygulanmıştır. Çalışmanın başında ve sonunda Visual analog skala (VAS) ile ağrı şiddeti, SF-36 anketi ile yaşam kalitesi değerlendirilmiştir. Ayrıca lazer termometre ile tedavi sonunda hastaların tedavi bölgesi cilt sıcaklıkları ve tedavi sırasında wattmetre ile enfraruj cihazlarının enerji tüketimleri ölçülmüştür. Bulgular: Çalışmanın sonunda her iki grupta da VAS ve SF-36 değerlerinde anlamlı fark vardı (p 0.05). Cilt ısısı ortalama değerleri klasik enfraruj cihazında 41,3 ℃ iken prototip cihazda 39,3 ℃ ölçüldü. Çalışmanın sonunda prototipin klasik enfraruj cihazına göre yaklaşık olarak %33 oranında enerji tasarrufu sağladığı tespit edildi. Sonuç: Bu pilot çalışmada prototipin klasik enfraruj cihazına göre ağrı da olumlu etkisi olduğu ancak SF-36 değerlerinde bir farkının olmadığı görüldü. Ayrıca cilt sıcaklığı ve enerji tüketiminde prototipin klasik enfraruj cihazına göre üstün olduğu tespit edildi.

🔖

Cite This Article

Torlak, M. S., Ervural, S., Dursun, B. (2026). Investigation of the Effect of an Automatic Distance-Adjusted Infrared Prototype Operating According to Skin Temperature on Individuals with Chronic Back Pain: A Pilot Study. KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi, Cilt: 7 Sayı: 1. https://doi.org/10.59244/ktokusbd.1862447

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (21)

  1. Abramson, D., Mitchell, R., Tuck, S., Bell, Y., & Zayas, A. (1961). Changes in blood flow, oxygen uptake and tissue temperatures produced by the topical application of wet heat. Archives of Physical Medicine and Rehabilitation, 42, 305-318. Erişim adresi: https://pubmed.ncbi.nlm.nih.gov/13681129/
  2. Angeles, R. N., Guenter, D., McCarthy, L., Bauer, M., Wolfson, M., Chacon, M., & Bullock, L. (2013). Group interprofessional chronic pain management in the primary care setting: A pilot study of feasibility and effectiveness in a family health team in Ontario. Pain Research & Management, 18(5), 237-242. (https://doi.org/10.1155/2013/491279)
  3. Chen, W. S., Annaswamy, T. M., Yang, W., & Wang, T. G. (2016). Physical agent modalities (D. X. Cifu, Ed.). Braddom’s physical medicine & rehabilitation (5. bs., s. 317–344). Elsevier. Dereniak, E. L., & Boreman, G. D. (1996). Infrared detectors and systems. Wiley Interscience. (https://lccn.loc.gov/96000212)
  4. Dodd, M. J. (1979). Caring for persons requiring applications of heat and cold. K. Sorensen & J. Luckmann (Ed.), Basic nursing: A psychophysiologic approach içinde. W.B. Saunders Co.
  5. French, S. D., Cameron, M., Walker, B. F., Reggars, J. W., & Esterman, A. J. (2006). Superficial heat or cold for low back pain. Cochrane Database of Systematic Reviews, 2006(1), CD004750. (https://doi.org/10.1002/14651858.CD004750.pub2)
  6. Freiwald, J., Magni, A., Fanlo-Mazas, P., Paulino, E., Sequeira de Medeiros, L., Moretti, B., Schleip, R., & Solarino, G. (2021). A role for superficial heat therapy in the management of non-specific, mild-to-moderate low back pain in current clinical practice: A narrative review. Life, 11(8), 780. (https://doi.org/10.3390/life11080780)
  7. Golovynska, I., Golovynskyi, S., Stepanov, Y. V., Stepanova, L. I., Qu, J., & Ohulchanskyy, T. Y. (2021). Red and near-infrared light evokes Ca2+ influx, endoplasmic reticulum release and membrane depolarization in neurons and cancer cells. Journal of Photochemistry and Photobiology B: Biology, 214, 112088. (https://doi.org/10.1016/j.jphotobiol.2020.112088)
  8. Kayıhan, H., & Dolunay, N. (1992). Isı, ışık, su. Hacettepe Üniversitesi Fizik Tedavi ve Rehabilitasyon Okulu Yayınları. Lee, D., Seo, Y., Kim, Y. W., Kim, S., Bae, H., Choi, J.,. & Ko, J. H. (2019). Far-infrared radiation stimulates platelet-derived growth factor mediated skeletal muscle cell migration through extracellular matrix-integrin signaling. Korean Journal of Physiology & Pharmacology, 23, 141–150. (https://doi.org/10.4196/kjpp.2019.23.2.141)
  9. Lehmann, J. F., Stonebridge, J. B., DeLateur, B. J., Warren, C. G., & Halar, E. (1978). Temperatures in human thighs after hot wrap treatment followed by ultrasound. Archives of Physical Medicine and Rehabilitation, 59, 472–475. (https://europepmc.org/article/med/363094)
  10. Low, J., & Reed, A. (1990). Electrotherapy explained: Principles and practice (2. bs.). Butterworth-Heinemann. Del Campo, F. F., Paneque, A., Ramirez, J. M., & Losada, M. (1963). Thermal transitions in collagen. Biochimica et Biophysica Acta, 66, 448-452. (https://doi.org/10.1016/0006-3002(63)91215-0)
  11. Robertson, V., Ward, A., Low, J., & Reed, A. (1994). Infrared and visible radiations. J. Low & A. Reed (Ed.), Electrotherapy explained: Principles and practice (2. bs.). Butterworth-Heinemann.
  12. Robertson, V., Ward, A., Low, J., & Reed, A. (2006). Electrotherapy explained: Principles and practice (4. bs.). Butterworth-Heinemann.
  13. Schieke, S. M., Schroeder, P., & Krutmann, J. (2003). Cutaneous effects of infrared radiation: From clinical observations to molecular response mechanisms. Photodermatology, Photoimmunology & Photomedicine, 19(5), 228–234. (https://doi.org/10.1034/j.1600-0781.2003.00054.x)
  14. Stillwell, G. K. (1965). General principles of thermotherapy. S. Licht (Ed.), Therapeutic heat and cold (2. bs.) içinde. Waverly Press.
  15. Thabane L., Ma J., Chu R., Cheng J., Ismaila A., Rios L.P., Robson, R., & Thabane M. (2010). A tutorial on pilot studies: the what, why and how. BMC Med Res Methodol. 23(1), 59. (https://doi.org/ 10.1186/1471-2288-10-1).
  16. Tottoli, C. R., Ben, Â. J., da Silva, E. N., Bosmans, J. E., van Tulder, M., Carregaro, R. L. (2024). Effectiveness of Pilates compared with home-based exercises in individuals with chronic non-specific low back pain: Randomised controlled trial. Clinical Rehabilitation, 38(11), 1495-1505. (https://doi.org/10.1177/02692155241277041)
  17. Tsai, S. R., & Hamblin, M. R. (2017). Biological effects and medical applications of infrared radiation. Journal of Photochemistry and Photobiology B: Biology, 170, 197–207. (https://doi.org/10.1016/j.jphotobiol.2017.04.014)
  18. Turvill, A., Maratos, F., & Sheffield, D. (2026). Assessing the impact of interdisciplinary multimodal pain treatment on health-related quality of life in chronic pain: A systematic review and meta-analyses. European Journal of Pain, 30(1), e70176. (https://doi.org/10.1002/ejp.70176)
  19. Ware, J. E., Jr., & Sherbourne, C. D. (1992). The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Medical Care, 30(6), 473-483. (http://www.jstor.org/stable/3765916?origin=JSTOR-pdf)
  20. Wewers, M. E., & Lowe, N. K. (1990). A critical review of visual analogue scales in the measurement of clinical phenomena. Research in Nursing & Health, 13(4), 227-236. (https://doi.org/10.1002/nur.4770130405)
  21. Kayıhan, H., & Dolunay, N. (1992). Isı, ışık, su. Hacettepe Üniversitesi Fizik Tedavi ve Rehabilitasyon Okulu Yayınları. Lee, D., Seo, Y., Kim, Y. W., Kim, S., Bae, H., Choi, J.,. & Ko, J. H. (2019). Far-infrared radiation stimulates platelet-derived growth factor mediated skeletal muscle cell migration through extracellular matrix-integrin signaling. Korean Journal of Physiology & Pharmacology, 23, 141–150. (https://doi.org/10.4196/kjpp.2019.23.2.141)