Journals / Ege Klinikleri Tıp Dergisi / 2019 / Cilt: 57 - Sayı: 3

Histerosalpingografi’de Transabdominal Sıcak Su Torbası Uygulamasının Beklenen Ağrı Üzerine Etkisi

The effect of Transabdominal Pelvic Hot Water Bag Application on The Perceived Pain of Hysterosalpingography

Pages
175–179
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Bulgular: Beklenen ve algılanan ağrı skorları, çalışma grubu ve kontrol grubunda sırasıyla 7.26±2.22 – 3.11±1.81, 6.48±1.99 – 3.98±1.88 olarak bulundu. (p <0.001) Tartışma: Histerosalpingografi öncesinde, 30 dakika süre boyunca karın üzerine konulan sıcak su torbası uygulamasının, doğrudan rahatlama veya analjezik etki olmasa da, hastanın dikkatini dağıttığı ve VAS skorlarını düşürdüğüne karar verdik.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Giriş: Histerosalpingografi(HSG), infertilite tanısında kullanılan başlıca tanı yöntemlerinden biridir.
📊
Key Findings & Data:HSG sırasında Transabdominal Pelvik Sıcak Su Torbası uygulamasının etkisini araştırdık.
💡
Conclusion & Impact:Bulgular: Beklenen ve algılanan ağrı skorları, çalışma grubu ve kontrol grubunda sırasıyla 7.26±2.22 – 3.11±1.81, 6.48±1.99 – 3.98±1.88 olarak bulundu. (p <0.001) Tartışma: Histerosalpingografi öncesinde, 30 dakika süre boyunca karın üzerine konulan sıcak su torbası uygulamasının, doğrudan rahatlama veya analjezik etki olmasa da, hastanın dikkatini dağıttığı ve VAS skorlarını düşürdüğüne karar verdik.
🔬Design:Research Article
📍Scope:1 hasta
⚙️Variables:Domain Parameters

Abstract

Giriş: Histerosalpingografi(HSG), infertilite tanısında kullanılan başlıca tanı yöntemlerinden biridir. HSG sırasında en sık görülen şikayet ağrıdır. HSG sırasında Transabdominal Pelvik Sıcak Su Torbası uygulamasının etkisini araştırdık. Yöntem: Bu prospektif randomize çalışmada, Grup 1 hastalara (n: 53) HSG işlemi öncesinde 41-44 °C’de sıcak su torbasını transabdominal olarak uyguladık. Grup 2 (n: 62) ise kontrol grubu olarak planlandı. HSG sırasında görülen ağrı, VAS ile değerlendirildi. Sıcak su torbası uygulamasının, VAS üzerinde ağrı skorlarının kontrol grubuna göre daha düşük olduğunu tespit ettik. Bulgular: Beklenen ve algılanan ağrı skorları, çalışma grubu ve kontrol grubunda sırasıyla 7.26±2.22 – 3.11±1.81, 6.48±1.99 – 3.98±1.88 olarak bulundu. (p <0.001) Tartışma: Histerosalpingografi öncesinde, 30 dakika süre boyunca karın üzerine konulan sıcak su torbası uygulamasının, doğrudan rahatlama veya analjezik etki olmasa da, hastanın dikkatini dağıttığı ve VAS skorlarını düşürdüğüne karar verdik.

Özet

Introduction: Hysterosalpingography (HSG) is one of the main diagnostic procedures in infertility. The most common complaint during HSG is pain. We investigated the effect of transabdominal Pelvic hot water bag application during HSG. Methods: In this prospective randomised study, Group 1 patients (n: 53) were treated with a hot water bottle at 41-44°C before the HSG procedure, Group 2 (n:62) was the control group. Perceived pain during HSG was evaluated with visual analog scale. We have detected that hot water bottle application lead to lower visual analog scale pain scores than the control group. Results: Expected and perceived pain scores of the study and the control groups were found to be 7.26±2.22 – 3.11±1.81 vs 6.48±1.99 – 3.98±1.88 p<0,001,respectively. Discussion: We conclude that 30 minutes long transabdominal hot water bottle application before HSG results in lower visual analog scale pain scores, at least by distraction of the patient, if not by the direct relaxation or analgesic effect.

🔖

Cite This Article

KINCI, M., KARAŞAHİN, K., FİDAN, U., ERŞEN, M., TAŞAR, M., YENEN, M. C. (2019). Histerosalpingografi’de Transabdominal Sıcak Su Torbası Uygulamasının Beklenen Ağrı Üzerine Etkisi. Ege Klinikleri Tıp Dergisi, Cilt: 57 - Sayı: 3, 175–179. https://ajindex.com/articles/152094

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Zhu, Y.Y., Mao, Y.Z., Wu, W.L. Comparison of warm and cold contrast media for hysterosalpingography: a prospective, randomized study.FertilSteril. 2012;97(6):1405-9
  2. Chauhan, M.B, Lakra, P., Jyotsna, D., Nanda, S., Malhotra, V. Pain relief during hysterosalpingography: role of intracervical block. Arch Gynecol Obstet. 2013;287(1):155-9
  3. Szymusik, I., Grzechocioska, B., Marianowski, P., Kaczyoski, B., Wielgoś, M. Factors influencing the severity of pain during hysterosalpingography.Int J Gynaecol Obstet. 2015;129(2):118-22
  4. Atalabi, O.M., Osinaike, B.B. Do abnormal findings on hysterosalphingographic examination correlate with intensity of procedure associated pain?Afr J Reprod Health. 2014;18(2):147-51
  5. Hindocha, A., Beere, L., O'Flynn, H., Watson, A., Ahmad, G. Pain relief in hysterosalpingography. Cochrane Database Syst Rev. 2015 20;9:CD006106
  6. Gupta, N., Ghosh, B., Mittal, S. Comparison of oral naproxen and intrauterine lignocaine instillation for pain relief during hysterosalpingography. Int J Gynaecol Obstet. 2008;102(3):284-6
  7. Cengiz, M., Kafali, H., Artuc, H., Baysal, Z. Opioid analgesia for hysterosalpingography: controlled double-blind prospective trial with remifentanil and placebo.GynecolObstet Invest. 2006;62(3):168-72
  8. Karasahin, E., Alanbay, I., Keskin, U., Gezginc, K., Baser, I. Lidocaine 10% spray reduces pain during hysterosalpingography: a randomized controlled trial. J ObstetGynaecol Res. 2009;35(2):354-8
  9. Hosono, T., Takashima, Y., Morita, Y., Nishimura, Y., Sugita, Y., Isami, C., et al. Effects of a heat- and steam-generating sheet on relieving symptoms of primary dysmenorrhea in young women. J ObstetGynaecol Res. 2010;36(4):818-24
  10. Potur, D.C., Kömürcü, N. The effects of local low-dose heat application on dysmenorrhea. J PediatrAdolesc Gynecol. 2014;27(4):216-21.