Journals / Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi Dergisi / 2025 / Volume: 12 Issue: 3

Assessing Concurrent Validity and Reliability of the S-Gait Insole: A Novel Tool for Measuring Weight Bearing

Pages
—
Publication Date
2025-12-31
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

By enabling portable WB assessment and real-time feedback that can be integrated into home-based or remote rehabilitation, the S-GAIT may facilitate patient compliance, telemonitoring, and more individualized therapeutic decision-making in musculoskeletal and neurological care.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: Accurate measurement of weight-bearing (WB) is critical in musculoskeletal and neurological rehabilitation, yet current systems are often costly and impractical for routine use.
📊
Key Findings & Data:Twenty-one healthy individuals (mean age 32.6 ± 7.3 years) participated.
💡
Conclusion & Impact:By enabling portable WB assessment and real-time feedback that can be integrated into home-based or remote rehabilitation, the S-GAIT may facilitate patient compliance, telemonitoring, and more individualized therapeutic decision-making in musculoskeletal and neurological care.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:orthopedic rehabilitation · weight bearing · insole

Abstract

Objectives: Accurate measurement of weight-bearing (WB) is critical in musculoskeletal and neurological rehabilitation, yet current systems are often costly and impractical for routine use. This study investigated the concurrent validity of the S-GAIT insole, a low-cost and portable tool, compared with the Digital Biometry Scanning System and Milletrix Software (DIASU, Italy). Materials and Methods: A cross-sectional, within-subject comparative design was applied to compare S-GAIT and DIASU. Twenty-one healthy individuals (mean age 32.6 ± 7.3 years) participated. WB of both lower extremities was assessed during quiet standing using both devices in a single laboratory session. Data were collected under standardized static conditions, and outcomes were statistically analyzed. Results: No significant differences were found between S-GAIT and DIASU in WB measures (p > 0.05). Strong Pearson correlations (r = 0.832–0.838, p < 0.001) and high intraclass correlation coefficients (ICC = 0.89–0.94, 95% CI: 0.73–0.95) were obtained. Bland–Altman analysis indicated low standard error of the mean for differences, confirming agreement between systems. Conclusions: The S-GAIT insole provided valid WB measurements when compared with DIASU under static conditions. Its strong psychometric properties and low cost support its potential as an economical, accessible, and clinically useful tool for objective WB quantification. By enabling portable WB assessment and real-time feedback that can be integrated into home-based or remote rehabilitation, the S-GAIT may facilitate patient compliance, telemonitoring, and more individualized therapeutic decision-making in musculoskeletal and neurological care.

Özet

Objectives: Accurate measurement of weight-bearing (WB) is critical in musculoskeletal and neurological rehabilitation, yet current systems are often costly and impractical for routine use. This study investigated the concurrent validity of the S-GAIT insole, a low-cost and portable tool, compared with the Digital Biometry Scanning System and Milletrix Software (DIASU, Italy). Materials and Methods: A cross-sectional, within-subject comparative design was applied to compare S-GAIT and DIASU. Twenty-one healthy individuals (mean age 32.6 ± 7.3 years) participated. WB of both lower extremities was assessed during quiet standing using both devices in a single laboratory session. Data were collected under standardized static conditions, and outcomes were statistically analyzed. Results: No significant differences were found between S-GAIT and DIASU in WB measures (p > 0.05). Strong Pearson correlations (r = 0.832–0.838, p < 0.001) and high intraclass correlation coefficients (ICC = 0.89–0.94, 95% CI: 0.73–0.95) were obtained. Bland–Altman analysis indicated low standard error of the mean for differences, confirming agreement between systems. Conclusions: The S-GAIT insole provided valid WB measurements when compared with DIASU under static conditions. Its strong psychometric properties and low cost support its potential as an economical, accessible, and clinically useful tool for objective WB quantification. By enabling portable WB assessment and real-time feedback that can be integrated into home-based or remote rehabilitation, the S-GAIT may facilitate patient compliance, telemonitoring, and more individualized therapeutic decision-making in musculoskeletal and neurological care.

🔖

Cite This Article

Beydağı, M. G., Apaydın, Z. B., Çakır, M., Deniz, H. G., Cıgercıoglu, N. B., Baltaci, Y. G. (2025). Assessing Concurrent Validity and Reliability of the S-Gait Insole: A Novel Tool for Measuring Weight Bearing. Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi Dergisi, Volume: 12 Issue: 3. https://doi.org/10.21020/husbfd.1787211

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (25)

  1. Bohannon, R. W., Waters, G., & Cooper, J. (1989). Perception of unilateral lower extremity weightbearing during bilateral upright stance. Perceptual and Motor Skills, 69(3 Pt 1), 875-880. http://doi.org/10.1177/00315125890693-130
  2. DiStasio, A., Jaggears, F., DePasquale, L., Frassica, F., & Turen, C. (1994). Protected early motion versus cast immobilization in postoperative management of ankle fractures. Contemporary Orthopaedics, 29(4), 273-277. https://europepmc.org/article/med/10150249
  3. Gapeyeva, H., Haviko, T., Märtson, A., Aibast, H., Ereline, J., & Pääsuke, M. (2012). Postural control in total knee arthroplasty patients with patellofemoral pain syndrome before and six months after re-operation. Journal of Foot and Ankle Research, 5(Suppl 1), O33. http://doi.org/10.1186/1757-1146-5-S1-O33
  4. Gray, F., Gray, C., & McClanahan, J. (1998). Assessing the accuracy of partial weight-bearing instruction. American Journal of Orthopedics (Belle Mead, NJ), 27(8), 558-560. https://europepmc.org/article/med/9732078
  5. Gupta, S., Dabke, H. V., Holt, C. A., O’Callaghan, P., Hayes, N., & Dent, C. M. (2004). How accurate is partial weight bearing? Orthopaedic Proceedings, 86-B(Suppl III), 376. http://doi.org/10.1302/0301-620X.86BSUPP_III.0860376c
  6. Hegde, N., & Sazonov, E. (2014). SmartStep: A fully integrated, low-power insole monitor. Electronics, 3(2), 381-397. http://doi.org/10.3390/electronics3020381
  7. Hurkmans, H., Bussmann, J., Benda, E., Verhaar, J., & Stam, H. (2006). Accuracy and repeatability of the Pedar Mobile system in long-term vertical force measurements. Gait & Posture, 23(1), 118-125. http://doi.org/10.1016/j.gaitpost.2005.05.008
  8. Hurkmans, H. L., Bussmann, J. B., Benda, E., Verhaar, J. A., & Stam, H. J. (2012). Effectiveness of audio feedback for partial weight-bearing in and outside the hospital: A randomized controlled trial. Archives of Physical Medicine and Rehabilitation, 93(4), 565-570. http://doi.org/10.1016/j.apmr.2011.11.019
  9. Hustedt, J. W., Blizzard, D. J., Baumgaertner, M. R., Leslie, M. P., & Grauer, J. N. (2012). Current advances in training orthopaedic patients to comply with partial weight-bearing instructions. The Yale Journal of Biology and Medicine, 85(1), 119-125. https://pmc.ncbi.nlm.nih.gov/articles/PMC3313526/
  10. Josipović, P. (2020). Availability and clinical use of different in-shoe devices for partial weight bearing – a systematic review. Journal of Applied Health Sciences, 6(2), 261-270. http://doi.org/10.24141/1/6/2/8
  11. Luo, Z.-P., Berglund, L. J., & An, K.-N. (1998). Validation of F-Scan pressure sensor system: A technical note. Journal of Rehabilitation Research and Development, 35(2), 186-191.
  12. Meadows, T. H., Bronk, J. T., Chao, Y. S., & Kelly, P. J. (1990). Effect of weight-bearing on healing of cortical defects in the canine tibia. Journal of Bone and Joint Surgery. American Volume, 72(7), 1074-1080. http://doi.org/10.2106/00004623-199072070-00018
  13. Meys, G., Kalmet, P. H., Sanduleanu, S., Van Horn, Y. Y., Maas, G. J., Poeze, M., & Seelen, H. A. (2019). A protocol for permissive weight-bearing during allied health therapy in surgically treated fractures of the pelvis and lower extremities. Journal of Rehabilitation Medicine, 51(4), 290-297. http://doi.org/10.2340/16501977-2532
  14. Price, C., Parker, D., & Nester, C. (2016). Validity and repeatability of three in-shoe pressure measurement systems. Gait & Posture, 46, 69-74. http://doi.org/10.1016/j.gaitpost.2016.01.026
  15. Putti, A., Arnold, G., Cochrane, L., & Abboud, R. (2007). The Pedar® in-shoe system: Repeatability and normal pressure values. Gait & Posture, 25(3), 401-405. http://doi.org/10.1016/j.gaitpost.2006.05.010
  16. Quesada, P., Rash, G., & Jarboe, N. (1997). Assessment of pedar and F-Scan revisited. Clinical Biomechanics, 12(Suppl 1), S15. http://doi.org/10.1016/S0268-0033(97)88328-3
  17. Reiff, A. L. (2016). Different in-shoe devices for partial weight bearing [Bachelor’s thesis, Faculty of Science and Engineering, University of Groningen, The Netherlands]. https://fse.studenttheses.ub.rug.nl/14470/
  18. Stöggl, T., & Martiner, A. (2017). Validation of Moticon’s OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements. Journal of Sports Sciences, 35(2), 196-206. http://doi.org/10.1080/02640414.2016.1161205
  19. Sturnieks, D. L., Menant, J., Valenzuela, M., Delbaere, K., Sherrington, C., Herbert, R. D., et al. (2019). Effect of cognitive-only and cognitive-motor training on preventing falls in community-dwelling older people: Protocol for the smart±step randomised controlled trial. BMJ Open, 9(8), e029409. http://doi.org/10.1136/bmjopen-2019-029409
  20. Tveit, M., & Kärrholm, J. (2001). Low effectiveness of prescribed partial weight bearing: Continuous recording of vertical loads using a new pressure-sensitive insole. Journal of Rehabilitation Medicine, 33(1), 42-46. http://doi.org/10.1080/165019701300006533
  21. Van Lieshout, R., Stukstette, M. J., de Bie, R. A., Vanwanseele, B., & Pisters, M. F. (2016). Biofeedback in partial weight bearing: Validity of 3 different devices. Journal of Orthopaedic & Sports Physical Therapy, 46(11), 993-1001. http://doi.org/10.2519/jospt.2016.6625
  22. Vasarhelyi, A., Baumert, T., Fritsch, C., Hopfenmüller, W., Gradl, G., & Mittlmeier, T. (2006). Partial weight bearing after surgery for fractures of the lower extremity – is it achievable? Gait & Posture, 23(1), 99-105. http://doi.org/10.1016/j.gaitpost.2004.12.005
  23. Winquist, R. A., & Frankel, V. H. (1986). Complications of implant use. In C. H. Epps (Ed.), Complications in Orthopaedic Surgery (pp. 149-156). J. B. Lippincott.
  24. Young, C. R. (1993). The F-SCAN system of foot pressure analysis. Clinics in Podiatric Medicine and Surgery, 10(3), 455-461. http://doi.org/10.1016/S0891-8422(23)00621-3
  25. Yu, S., McDonald, T., Jesudason, C., Stiller, K., & Sullivan, T. (2014). Orthopedic inpatients’ ability to accurately reproduce partial weight-bearing orders. Orthopedics, 37(1), e10-e18. http://doi.org/10.3928/01477447-20131219-10