Journals / Adli Tıp Dergisi / 2012 / Cilt: 26 Sayı: 3

DETERMINATION OF BLOOD ETHANOL LEVELS: COMPARISON OF ENZYMATIC AND GAS CHROMATOGRAPHIC METHODS

Nebile Dağlıoğlu(Çukurova Üniversitesi Tıp Fakültesi Adli Tıp Anabilim Dalı)
Alper Keten(Adalet Bakanlığı, Adli Tıp Kurumu, Kahramanmaraş Şube Müdürlüğü)
Ramazan Akçan(Hacettepe Üniversitesi Tıp Fakültesi Adli Tıp Anabilim Dalı)
Pınar Efeoğlu(Çukurova Üniversitesi Tıp Fakültesi Adli Tıp Anabilim Dalı)
Necmi Çekin(Çukurova Üniversitesi Tıp Fakültesi Adli Tıp Anabilim Dalı)
Pages
89–91
Publication Date
2012-12-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: GC-HS still remains as a specific, accurate and reliable method for determination of ethanol levels.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Forensic and clinical laboratories determine blood alcohol concentrations (BAC) using gas chromatography–head space, and enzymatic ethanol assay methods.
📊
Key Findings & Data:Several authors have reported that increased concentrations of lactate dehydrogenase might cause false-positive results with enzymatic ethanol assays.
💡
Conclusion & Impact:Conclusion: GC-HS still remains as a specific, accurate and reliable method for determination of ethanol levels.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:blood alcohol concentration · enzymatic ethanol assay · gas chromatography-head space

Abstract

Objective: Forensic and clinical laboratories determine blood alcohol concentrations (BAC) using gas chromatography–head space, and enzymatic ethanol assay methods. However, the use of enzymatic ethanol assays is still controversial. Several authors have reported that increased concentrations of lactate dehydrogenase might cause false-positive results with enzymatic ethanol assays. This study was designed to compare the Roche® enzymatic method with the reliable conventional gas chromatographic method. Methods: The blood samples collected from 20 voluntary individuals (3 females and 17 males) were analyzed by both methods. A control group was constituted from 10 healthy individuals that were non-users of alcohol. Results: Blood LDH levels of all participants were varying between 294-932 U/L. A significant correlation related with the effect of LDH level on BAC was not detected since the LDH levels were in normal range. The present study shows significant quantitative difference in detected blood ethanol levels of the experimental group between the enzymatic and gas chromatographic methods. All samples of alcohol users were positive and the percentage difference between BAC obtained by the enzymatic versus the GCHS method ranged from -166 to +17%. Nineteen (95%) in 20 positive samples showed lower detected ethanol values with the enzymatic method compared to GC-HS analysis. Despite the fact that ethanol was found to be negative in all samples of the control group with GC-HS method, enzymatic method gave false positive results for two samples (10%) of the control group. Conclusion: GC-HS still remains as a specific, accurate and reliable method for determination of ethanol levels.

🔖

Cite This Article

Dağlıoğlu, N., Keten, A., Akçan, R., Efeoğlu, P., Çekin, N. (2012). DETERMINATION OF BLOOD ETHANOL LEVELS: COMPARISON OF ENZYMATIC AND GAS CHROMATOGRAPHIC METHODS. Adli Tıp Dergisi, Cilt: 26 Sayı: 3, 89–91. https://ajindex.com/articles/1352710

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. Nine JS, Moraca M, Virci MA, Rao KN. Serum-ethanole determination: Comparison of lactate and lactate dehidrogenase interference in three enzymatic assays. J Anal Tox 1995;19:192-6.
  2. Badcock NR, O’Reilly DA. False positive ethanol results with EMIT®. Clin Chem 1993;39:1143.
  3. Thompson WC, Malhorta D, Blackwell W, Ward M, Dasgupta A. False positive ethanol in clinical and postmortem sera by enzmatic assay: elimination of interference by measuring alcohol in protein-free ultrafiltrate. Clin Chem 1984;40:8.
  4. Levine B. Principles of Forensic Toxicology. 2nd ed. USA, AACC Press. 2003.
  5. Eder AF, Dowdy YG, Gardiner JAM, Wolf BA, Shaw LM. Serum lactate and lactate dehidrogenase in high concentrations interfere in enzymatic assay of ethylene glycol. Clin Chem 1996;42:9.
  6. Winek CL, Wahba WW, Windisch RM, Winek CL Jr. Serum alcohol concentrations in trauma patients determined by immunoassay versus gas chromatography. Forensic Sci Int 2004;139:1-3.
  7. Gharapetian A, Holmes DT, Urquhart N, Rosenberg F. Dehidrogenase interference with enzymatic ethanol assay: Forgotten but not gone. Clin Chem 2008;54:7.
  8. Peek GJM, Keating JW, Ward RJ, Peter TJ, Archer GJ, Khawar MK. Alcohol swabs and venepuncture. Lancet 1989;1:1388.
  9. Malingre M, Ververs T, Bos S, Kesteren CV. Alcohol swabs and venipuncture in a routine hospital setting: no effect on blood ethanol measurement. Ther Drug Monit 2005;27:403-4.