Journals / Isı Bilimi ve Tekniği Dergisi / 2018 / Cilt: 38 - Sayı: 1

PERFORMANCE TESTING OF A PARABOLIC TROUGH COLLECTOR ARRAY FOR A SMALL-SCALE PROCESS HEAT APPLICATION

KÜÇÜK-ÖLÇEKLİ BİR PROSES ISI UYGULAMASINA İLİŞKİN PARABOLİK OLUK KOLEKTÖR AĞININ PERFORMANS TESTİ

Pages
43–53
Publication Date
2018-04-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally, the experimental results were compared with the results of the theoretical study made previously and gave good coherency.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study presents the experimental investigation on performance testing of a parabolic trough solar collector (PTSC) array consisting of three modules connected in series.
📊
Key Findings & Data:A new test setup has been proposed to test the thermal performance of this PTSC array in compliance with ASHRAE 93-1986 standard.
💡
Conclusion & Impact:Additionally, the experimental results were compared with the results of the theoretical study made previously and gave good coherency.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Güneş enerjisi · Parabolik oluk kolektör · Optik analiz

Abstract

This study presents the experimental investigation on performance testing of a parabolic trough solar collector (PTSC) array consisting of three modules connected in series. A new test setup has been proposed to test the thermal performance of this PTSC array in compliance with ASHRAE 93-1986 standard. The experimental tests have been carried out and monitored in a number of days under cloudless sky conditions in Gaziantep. In the performance analyses, the effects of beam radiation, collector inlet temperature, ambient conditions, and the variation in mass flow rate of the working fluid were investigated. The steady-state and dynamic tests of the PTSC array were performed. The efficiency tests were conducted with thermal oil for the temperature range from 50 °C to 200 °C, and mass flow rate of 0.1 kg/s to 0.5 kg/s under steady conditions. Additionally, the experimental results were compared with the results of the theoretical study made previously and gave good coherency.

Özet

Bu çalışma, seri bağlanmış üç modülden oluşan bir parabolik oluk güneş kolektör (POGK) ağının performans testinin deneysel olarak incelenmesini sunmaktadır. Bu POGK ağının ısıl performansının ASHRAE 93-1986 standardına uygun olarak test edilmesi için yeni bir test düzeneği önerilmiştir. Deneysel testler, Gaziantep'te bulutsuz gökyüzü koşulları altında uygulanmış ve birkaç gün boyunca izlenmiştir. Performans analizlerinde, direk ışınım, kolektör giriş sıcaklığı, ortam koşulları ve çalışma akışkanının kütlesel akış debisinin etkileri araştırılmıştır. POGK ağının daimi-durum ve dinamik testleri gerçekleştirilmiştir. Verimlilik testleri, termal yağ kullanılarak daimi koşullar altında 50 °C ila 200 °C sıcaklık aralığı ve 0,1 kg/s ila 0,5 kg/s kütlesel debi aralığı için gerçekleştirilmiştir. Ayrıca, deney sonuçları daha önce yapılan teorik çalışma sonuçlarıyla karşılaştırılmış ve iyi tutarlılık göstermiştir.

🔖

Cite This Article

YILMAZ, İ., HAYTA, H., YUMRUTAŞ, R., SÖYLEMEZ, M. (2018). PERFORMANCE TESTING OF A PARABOLIC TROUGH COLLECTOR ARRAY FOR A SMALL-SCALE PROCESS HEAT APPLICATION. Isı Bilimi ve Tekniği Dergisi, Cilt: 38 - Sayı: 1, 43–53. https://ajindex.com/articles/133379

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. ANSI/ASHRAE 93-1986 (RA91), 1986, Methods of Testing to Determine the Thermal Performance of Solar Collectors. Arasu A. V. and Sornakumar T., 2007, Design, manufacture and testing of fiberglass reinforced parabola trough for parabolic trough solar collectors, Sol. Energy, 81, 1273–1279.
  2. Brooks M. J., Mills I. and Harms T. M., 2006, Performance of a parabolic trough solar collector. J. Energy South Afr., 17(3), 71–80.
  3. Coccia G., Nicola G. D. and Sotte M., 2015, Design, manufacture, and test of a prototype for a parabolic trough collector for industrial process heat, Renew. Energ., 74, 727–736.
  4. Dudley V. E., Evans L. R. and Matthews C. V., 1995, Test Results – Industrial Solar Technology Parabolic Trough Solar Collector. Sandia National Laboratories, SAND94-1117. Duffie J. A. and Beckman W. A., 2005, Solar engineering of thermal processes (Third Ed.), John Wiley & Sons, New York. Eskin N., 1999, Transient performance analysis of cylindrical parabolic concentrating collectors and comparison with experimental, Energ. Convers. Manage., 40, 175–191.
  5. Fernandez-Garcia A., Zarza E., Valenzuela L. and Perez M., 2010, Parabolic-trough solar collectors and their applications, Renew. Sust. Energ. Rev., 14, 1695–1721.
  6. Fischer S., Lüpfert E. and Müller-Steinhagen H., 2006, Efficiency testing of parabolic trough collectors using the quasi-dynamic test procedure according to the European standard EN 12975, SolarPACES 13th Symposium on Concentrating Solar power and Chemical Energy Technologies, Seville, Spain. Gama A., Larbes C., Malek A., Yettou F. and Adouane B., 2013, Design and realization of a novel sun tracking system with absorber displacement for parabolic trough collectors, J. Renew. Sustain. Ener., 5, 033108–1/18. Gnielinski V., 1976, New equations for heat and mass transfer in turbulent pipe and channel flow, Int. Chem. Eng., 16, 359–68. Internet, 2017a, Technical datasheet of Pt100, http:// www.ordel.com.tr. Internet, 2017b, Optimass 6000 technical datasheet, http://www.krohne.com. Internet, 2017c, Type 40 maximum anemometer, http://www.renewablenrgsystems.com. Internet, 2017d, Technical datasheet of CMP11, http://www.kippzonen.com. Internet, 2017e, USB-2416 and USB-TEMP User’s Guide, http://www.mccdaq.com.
  7. Jaramillo O. A., Venegas-Reyes E., Aguilar J. O., Castrejón-García R. and Sosa-Montemayor F., 2013, Parabolic trough concentrators for low enthalpy processes, Renew. Energ., 60, 529–539.
  8. Kalogirou S. A., Lloyd S., Ward J. and Eleftheriou P., 1994, Design and