Growth of Listeria monocytogenes as Affected by Thermal Treatments of Rainbow Trout Fillets Prepared with Liquid Smoke

Pages
—
Publication Date
2012-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The lower temperature, longer time treatment (30 ˚C, 3 h) was not efficient to control L. monocytogenes, did not eliminate the bacterium and survivors multiplied at 4˚C in package bags.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Dipping rainbow trout slices into liquid smoke flavoring and applying one of two heat treatments was effective in reducing the initial inoculation levels of Listeria monocytogenes.
📊
Key Findings & Data:The liquid smoke treatment against L. monocytogenes was dipping for 10-30 min with longest duration being most favorable for inactivation.
💡
Conclusion & Impact:The lower temperature, longer time treatment (30 ˚C, 3 h) was not efficient to control L. monocytogenes, did not eliminate the bacterium and survivors multiplied at 4˚C in package bags.
🔬Design:Makale
📍Scope:Comprehensive Sample
⚙️Variables:Listeria monocytogenes · liquid smoke flavoring · antimicrobial effects

Abstract

Dipping rainbow trout slices into liquid smoke flavoring and applying one of two heat treatments was effective in reducing the initial inoculation levels of Listeria monocytogenes. The liquid smoke treatment against L. monocytogenes was dipping for 10-30 min with longest duration being most favorable for inactivation. A thermal treatment of 65 ˚C for 20 min had eliminated by 2- or 4 logs the two levels of inocula. The lower temperature, longer time treatment (30 ˚C, 3 h) was not efficient to control L. monocytogenes, did not eliminate the bacterium and survivors multiplied at 4˚C in package bags.

Özet

Dipping rainbow trout slices into liquid smoke flavoring and applying one of two heat treatments was effective in reducing the initial inoculation levels of Listeria monocytogenes. The liquid smoke treatment against L. monocytogenes was dipping for 10-30 min with longest duration being most favorable for inactivation. A thermal treatment of 65 ˚C for 20 min had eliminated by 2- or 4 logs the two levels of inocula. The lower temperature, longer time treatment (30 ˚C, 3 h) was not efficient to control L. monocytogenes, did not eliminate the bacterium and survivors multiplied at 4˚C in package bags.

🔖

Cite This Article

Kılınç, B., Çaklı, Ş. (2012). Growth of Listeria monocytogenes as Affected by Thermal Treatments of Rainbow Trout Fillets Prepared with Liquid Smoke. Turkish Journal of Fisheries and Aquatic Sciences, Cilt: 12 Sayı: 2. https://ajindex.com/articles/1325156

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...