Journals / Meandros Medical And Dental Journal / 2026 / Volume: 27 Issue: 2

Comparison of the Reliability of Linear Mandible Measurements on Cone Beam Computed Tomography Images Obtained from Dry Human Mandible Using Three Different Inclinations

Üç Farklı Eğim Kullanılarak Kuru İnsan Mandibulasından Elde Edilen Konik Işınlı Bilgisayarlı Tomografi Görüntülerinde Doğrusal Mandibula Ölçümlerinin Güvenilirliğinin Karşılaştırılması

Gülçin Kılcı(Aydın Ağız ve Diş Sağlığı Merkezi)0000-0002-3766-4228
Selin Yeşiltepe(AYDIN ADNAN MENDERES ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, AĞIZ, DİŞ VE ÇENE RADYOLOJİSİ ANABİLİM DALI)0000-0002-6857-1411
Begüm İncedemir Ündey(AYDIN ADNAN MENDERES ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, ANATOMİ ANABİLİM DALI)0000-0002-2018-9184
Hulki Başaloğlu(AYDIN ADNAN MENDERES ÜNİVERSİTESİ, TIP FAKÜLTESİ, TEMEL TIP BİLİMLERİ BÖLÜMÜ, ANATOMİ ANABİLİM DALI)0000-0002-0904-3539
Pages
—
Publication Date
2026-06-24
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Especially, we can say that the inclined forward positions of the mandible may affect the vertical measurements made according to the mandible regions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study is to compare the linear measurements made on the images obtained from three different inclinations using cone-beam computed tomography (CBCT) from the dry bone mandibles with the anatomical measurements made directly on the dry bone mandibles, to evaluate and discuss the compatibility between these measurements.
📊
Key Findings & Data:Material and Methods: The study included 20 dry bone mandibles and a total of 60 CBCT images were obtained for each jaw with the mandibular base parallel to the floor (parallel position) as well as +45º (up position) and -45º angle (down position).
💡
Conclusion & Impact:Especially, we can say that the inclined forward positions of the mandible may affect the vertical measurements made according to the mandible regions.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cone-beam computed tomography · mandible · linear measurements reliability

Abstract

Objective: The aim of this study is to compare the linear measurements made on the images obtained from three different inclinations using cone-beam computed tomography (CBCT) from the dry bone mandibles with the anatomical measurements made directly on the dry bone mandibles, to evaluate and discuss the compatibility between these measurements. Material and Methods: The study included 20 dry bone mandibles and a total of 60 CBCT images were obtained for each jaw with the mandibular base parallel to the floor (parallel position) as well as +45º (up position) and -45º angle (down position). Linear measurements were made on the images obtained from with different inclinations. Results: Statistically significant differences were found between the three positions in CBCT measurements of the distance between the laterals of the right and left condyles, the distance between the right and left coronoid processes, the distance between the left coronoid point and the left mental foramen, and the distances between the left coronoid point and the right mental foramen. Conclusion: The reliability of measurements made on CBCT images using prominent anatomical landmarks does not depend on the experience of the operator, the measurements made on CBCT tend to be slightly less predictive than the anatomical measurements, all the measurements obtained in the down position in the CBCT scan are higher than the measurements in the up and parallel positions. Especially, we can say that the inclined forward positions of the mandible may affect the vertical measurements made according to the mandible regions.

Özet

Amaç: Bu çalışmanın amacı, kuru kemik mandibulalarından konik ışınlı bilgisayarlı tomografi (CBCT) kullanılarak üç farklı eğimden elde edilen görüntüler üzerinde yapılan doğrusal ölçümleri, doğrudan kuru kemik mandibulaları üzerinde yapılan anatomik ölçümlerle karşılaştırmak, bu ölçümler arasındaki uyumluluğu değerlendirmek ve tartışmaktır. Gereç ve Yöntemler: Çalışmaya 20 kuru kemik mandibula dahil edildi ve her çene için mandibular tabanı zemine paralel (paralel pozisyon) ve +45º (yukarı pozisyon) ve -45º (aşağı pozisyon) açıyla olmak üzere toplam 60 CBCT görüntüsü elde edildi. Farklı eğimlerden elde edilen görüntüler üzerinde doğrusal ölçümler yapıldı. Bulgular: KIBT ölçümlerinde, sağ ve sol kondil lateralleri arasındaki mesafe, sağ ve sol koronoid çıkıntılar arasındaki mesafe, sol koronoid nokta ile sol mental foramen arasındaki mesafe ve sol koronoid nokta ile sağ mental foramen arasındaki mesafe olmak üzere üç pozisyon arasında istatistiksel olarak anlamlı farklar bulunmuştur. Sonuç: Belirgin anatomik işaret noktaları kullanılarak KIBT görüntüleri üzerinde yapılan ölçümlerin güvenilirliği, operatörün deneyimine bağlı değildir, KIBT'de yapılan ölçümler anatomik ölçümlere göre biraz daha az öngörücü olma eğilimindedir, KIBT taramasında aşağı pozisyonda elde edilen tüm ölçümler, yukarı ve paralel pozisyonlardaki ölçümlerden daha yüksektir.

🔖

Cite This Article

Kılcı, G., Yeşiltepe, S., Ündey, B. İ., Başaloğlu, H. (2026). Comparison of the Reliability of Linear Mandible Measurements on Cone Beam Computed Tomography Images Obtained from Dry Human Mandible Using Three Different Inclinations. Meandros Medical And Dental Journal, Volume: 27 Issue: 2. https://doi.org/10.69601/meandrosmdj.1775601

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (25)

  1. Tecco S, Saccucci M, Nucera R, Polimeni A, Pagnoni M, Cordasco G, et al. Condylar volume and surface in Caucasian young adult subjects. BMC medical imaging. 2010;10(1):1- 10.
  2. Singh B, Kumar NR, Balan A, Nishan M, Haris P, Jinisha M, et al. Evaluation of Normal Morphology of Mandibular Condyle: A Radiographic Survey. Journal of Clinical Imaging Science. 2020;10.
  3. Chinea S. The effect of cone beam computed tomography (CBCT) imaging on orthodontic diagnosis and treatment planning: University of Southern California. 2011.
  4. Nayak S, Patra S, Singh G, Mohapatra C, Rath S. Study of the size of the coronoid process of mandible. IOSR J Dent Med Sci 2015;14:66–9.
  5. Zhong SC, Xu ZJ, Zhang ZG, Zheng YH, Li TX, Su K. Bilateral coronoid hyperplasia (Jacob disease on right and elongation on left): report of a case and literature review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107:e64-7.
  6. Aher V, Pillai P, Ali MF, Mustafa M, Ahire M, Mudhol A, Kadri M. Anatomical Position of Mental foramen: a Review. Glob J Med Public Health. 2012;1(1):61-4.
  7. Bello SA, Adeoye JA, Ighile N, Ikimi NU. Mental foramen size, position and symmetry in a multi-ethnic, urban black population: Radiographic evidence. Journal of oral & maxillofacial research. 2018;9(4).
  8. Phillips JL, Weller RN, Kulild JC. The mental forman: Part I. Size, orientation, and positional relationship to the mandibular second premolar. Journal of endodontics. 1990;16(5):221-3.
  9. Shah S, Vaze S, Kinhal K. A variation in the position of the mental foramen: a case report. Journal of maxillofacial and oral surgery. 2010;9(3):307-9.
  10. Genú PR, V asconcellos RJdH, Oliveira BPd, V asconcelos BCGd, Delgado NCdC. Analysis of anatomical landmarks of the mandibular interforaminal region using CBCT in a Brazilian population. Brazilian Journal of Oral Sciences. 2014;13(4):303-7.
  11. Tomasi C, Bressan E, Corazza B, Mazzoleni S, Stellini E, Lith A. Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations. Dentomaxillofacial Radiology. 2011;40(4):244-250.
  12. Lascala C, Panella J, Marques M. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofacial Radiology. 2004;33(5):291-4.
  13. Halperin-Sternfeld M, Machtei EE, Horwitz J. Diagnostic accuracy of cone beam computed tomography for dimensional linear measurements in the mandible. The International Journal of Oral & Maxillofacial Implants. 2014: 29(3): 593– 599.
  14. Tomasi C, Bressan E, Corazza B, Mazzoleni S, Stellini E, Lith A. Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations. Dentomaxillofac Radiol. 2011 May;40(4):244-50.
  15. Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography. Dentomaxillofac Radiol. 2004 Sep;33(5):291-4.
  16. Han SS, Lee KM, Kim KD. Availability of software-based correction of mandibular plane for the vertical measurement of the mandible in cone beam computed tomography. Biomed Res Int. 2015; 2015: 808625.
  17. Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Apr;103(4):534-42.
  18. Portney LG. Foundations of clinical research: applications to evidence-based practice. Fourth edition. F.A Davis, Philadelphia.2020; p:491.
  19. Fernandes TM, Adamczyk J, Poleti ML, Henriques JF, Friedland B, Garib DG. Comparison between 3D volumetric rendering and multiplanar slices on the reliability of linear measurements on CBCT images: an in vitro study. J Appl Oral Sci. 2015 Jan-Feb;23(1):56-63.
  20. Naitoh M, Yamada S, Noguchi T, Ariji E, Nagao J, Mori K, et al. Three-dimensional display with quantitative analysis in alveolar bone resorption using cone-beam computerized tomo graphy for dental use: a preliminary study. Int J Periodontics Restorative Dent 2006; 26: 607–612.
  21. Naitoh M, Katsumata A, Mitsuya S, Kamemoto H, Ariji E. Measurement of mandibles with microfocus x-ray computerized tomography and compact computerized tomography for dental use. Int J Oral Maxillofac Implants 2004; 19: 239–246.
  22. Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implants 2004; 19: 228–231.
  23. Mischkowski RA, Pulsfort R, Ritter L, Neugebauer J, Brochhagen HG, Keeve E, et al. Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 551–559.
  24. Lund H, Grondahl K, Grondahl HG. Accuracy and precision of linear measurements in cone beam computed tomography Accuitomo tomograms obtained with different reconstruction techniques. Dentomaxillofac Radiol 2009; 38: 379–386.
  25. Berco M, Rigali PH Jr, Miner RM, DeLuca S, Anderson NK, Will LA. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull. Am J Orthod Dentofacial Orthop. 2009;136(1):17e1