Journals / Dicle Tıp Dergisi / 2016 / Cilt: 42 Sayı: 4

The predictive value of three-dimensional Doppler ultrasonography in determining implantation in patients underwent in vitro fertilization

Pages
472–479
Publication Date
2016-01-08
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Key words: Doppler ultrasonography, in vitro fertilization, pregnant women

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study is to evaluate the relationship between endometrial and sub-endometrial blood flow and implantation rate in patients whose undergone in vitro fertilization.
📊
Key Findings & Data:Endometrial and sub-endometrial blood flow was evaluated by using 3 dimensional Doppler ultrasonography on the day of oocyt retrieval measurement.
💡
Conclusion & Impact:Key words: Doppler ultrasonography, in vitro fertilization, pregnant women
🔬Design:Makale
📍Scope:Comprehensive Sample
⚙️Variables:Doppler ultrasonografi · gebe kadınlar · invitro fertilizasyon

Özet

Objective: The aim of this study is to evaluate the relationship between endometrial and sub-endometrial blood flow and implantation rate in patients whose undergone in vitro fertilization. Methods: A prospective study was conducted. Long protocol and antagonist regimens were administered to the patients. Endometrial and sub-endometrial blood flow was evaluated by using 3 dimensional Doppler ultrasonography on the day of oocyt retrieval measurement. For comparison pregnant and non-pregnant women in terms of endometrial and sub-endometrial blood flow, t test was used. The p value was considered statistically meaningful as <0.05. Results: Endometrial and sub-endometrial blood flow was not different between pregnant and non-pregnant women in both groups (p>0.05). In long protocol group, the number of embryo was greater in pregnant women than non-pregnant women (p=0.012). The number of transferred embryo increased pregnancy rate almost 3.5 fold (p=0.002). Conclusion: The endometrial and subendometrial blood flow is not reliable factor in prediction pregnancy or implantation. Key words: Doppler ultrasonography, in vitro fertilization, pregnant women

🔖

Cite This Article

Çakmak, Y., Şentürk, M., Budak, M. (2016). The predictive value of three-dimensional Doppler ultrasonography in determining implantation in patients underwent in vitro fertilization. Dicle Tıp Dergisi, Cilt: 42 Sayı: 4, 472–479. https://doi.org/10.5798/diclemedj.0921.2015.04.0611

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (31)

  1. Ng EH, Chan CC, Tang OS, Ho PC. Comparison of 2-dimensional,
  2. dimensional, and vascular ultrasonographic parameters for endometrial receptivity between 2 consecutive stimulated in vitro fertilization cycles. J Ultrasound Med. 2007;26:931-939.
  3. Bahar L, Kahraman S, Akkus A, Baykal T. Fine structure and
  4. immune histochemical evaluation of endometrium in fertile and infertile women with implantation failure. Dicle Medical Journal 2012;39:269-295.
  5. Gannon BJ, Carati CJ, Verco CJ. Endometrial perfusion across the normal human menstrual cycle assessed by laser Doppler fluxmetry. Hum Reprod. 1997;12:132-139.
  6. Raine-Fenning NJ, Campbell BK, Clewes JS, Kendall NR, Johnson IR. The reliability of virtual organ computer-aided analysis (VOCAL) for the semi quantification of ovarian, endometrial and subendometrial perfusion. Ultrasound Obstet Gynecol 2003;22:633-639.
  7. Chien LW, Au HK, Chen PL, et al. Assessment of uterine receptivity by the endometrial-subendometrial blood flow distribution pattern in women undergoing in vitro fertilization-embryo transfer. Fertil Steril 2002;78:245-251.
  8. Hsieh YY, Chang FC, Tsai HD. Doppler evaluation of the uterine and spiral arteries from different sampling sites and phases of the menstrual cycle during controlled ovarian hyper-stimulation.
  9. Ultrasound Obstet. Gynecol 200;16:192-196.
  10. Raine-Fenning N. The role of three-dimensional ultrasound in assisted reproduction treatment. Ultrasound Obstet Gynecol 2004;23:317-322.
  11. Ng EH, Chan CC, Tang OS, et al. The role of endometrial and sub-endometrial blood flows measured by three-dimensional power Doppler ultrasound in the prediction of pregnancy during IVF treatment. Hum Reprod 2006;21:164-170.
  12. Guerriero S, Ajossa S, Lai MP, et al. Clinical applications of colour Doppler energy imaging in the female reproductive tract and pregnancy. Hum Reprod Update 1999;5:515-529.
  13. Zaidi J, Campbell S, Pittrof FR and Tan SL. Endometrial
  14. thickness morphology, vascular penetration and velocimetry in predicting implantation in an IVF program. Ultrasound Obstet Gynecol 1995;6:191-198.
  15. Ng EHY, Chan CCW, Tang OS, et al. Endometrial and subendometrial blood flow measured during early luteal phase
  16. by three dimensional Power Doppler ultrasound in excessive ovarian responders. Hum Reprod 2004;19:924-931.
  17. Merce LT, Barco MJ, Bau S, Troyano J. Are endometrial parameters by three-dimensional ultrasound and power Doppler
  18. angiography related to in vitro fertilization/embryo transfer outcome? Fertil Steril 2008;89:111.
  19. Achache H, Revel A. Endometrial receptivity markers, the
  20. journey to successful embryo implantation. Hum Reprod Update 2006;12:731.
  21. Kim A, Jung H, Choi WJ, et al. Detection of endometrial and sub-endometrial vasculature on the day of embryo transfer and prediction of pregnancy during fresh in vitro fertilization cycles. Taiwan J Obstet Gynecol 2014;53:360-365.
  22. Battaglia C, Artini PG, Giulini S, et al. Colour Doppler changes and thromboxane production after ovarian stimulation with gonadotrophin- releasing hormone agonist. Hum Reprod 1997;12:2477-2482.
  23. Kupesic S, Bekavac I, Bjelos D, Kurjak A. Assessment of endometrial receptivity by transvaginal color Doppler and three-dimensional power Doppler ultrasonography in patients undergoing in vitro fertilization procedures. J Ultrasound Med 2001;20:125-134.
  24. angiography related to in vitro fertilization/embryo transfer outcome? Fertil Steril 2008;89:111-117.
  25. Wu HM, Chiang CH, Huang HY, et al. Detection of the subendometrial vascularization flow index by three-dimensional
  26. ultrasound may be useful for predicting the pregnancy rate for patients undergoing in vitro fertilization-embryo transfer. Fertil Steril 2003;79:507-511.
  27. Dechaud H, Bessueille E, Bousquet PJ, et al. Optimal timing of ultrasonographic and Doppler evaluation of uterine receptivity to implantation.Reprod Biomed Online.2008;16:368-375.
  28. Fraser IS, Mc Carron G, Hutton B, Macey D. Endometrial blood flow measured by xenon 133 clearance in women with normal menstrual cycles and dysfunctional uterine bleeding. Am J Obstet Gynecol 1987;156:158-166.
  29. Nandi A, Martins WP, Jayaprakasan K, et al. Assessment of endometrial and subendometrial blood flow in women undergoing frozen embryo transfer cycles. Reprod Biomed Online. 2014;28:343-351.
  30. Spandorfer SD, Arrendondo-Soberon F, Loret de Mola JR, Feinberg RF. Reliability of intraobserver and interobserver sonographic endometrial stripe thickness measurements. Fertil Steril 1998;70:152-154.
  31. Raine-Fenning NJ, Clewes JS, Kendall NR, et al. The inter observer reliability and validity of volume calculation from three-dimensional ultrasound data sets in the in vitro setting. Ultrasound Obstet Gynecol 2003;21:283-291