Journals / Dicle Tıp Dergisi / 2021 / Cilt: 48 Sayı: 1

Evaluation of Corneal Optic Quality in Amblyopia

Hasan Öncül(DİYARBAKIR GAZİ YAŞARGİL SAĞLIK UYGULAMA VE ARAŞTIRMA MERKEZİ)
Pages
1–8
Publication Date
2021-03-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This may be related to some compensation mechanisms and/or microstructural changes in the cornea

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To compare corneal aberrations and densitometry values in children with amblyopia due to anisometropic hyperopia with those of healthy children.
📊
Key Findings & Data:Methods: This study included 173 children with amblyopia due to hyperopic anisometropia in one eye and 173 children with both healthy eyes.
💡
Conclusion & Impact:This may be related to some compensation mechanisms and/or microstructural changes in the cornea
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:amblyopia · corneal densitometry · optic quality

Abstract

Objective: To compare corneal aberrations and densitometry values in children with amblyopia due to anisometropic hyperopia with those of healthy children. Methods: This study included 173 children with amblyopia due to hyperopic anisometropia in one eye and 173 children with both healthy eyes. The amblyopic eye (Group 1) and the fellow normal eye (Group 2) of the amblyopic patients and the right eye of the healthy control group (Group 3) were evaluated. Of the corneal aberration and corneal densitometry (CD)measured using Scheimpflug corneal topography values were noted. Results: While there was a significant difference in total root mean square (RMS), higher-order aberration (HOA) RMS, coma horizontal, trefoil horizontal and spherical aberration values between the groups (p<0.001, p<0.001, p<0.001, p<0.001, p=0.008, respectively), there was no difference between coma vertical and trefoil oblique values (p=0.076, p=0.074, respectively). There was no significant difference in terms of CD values in the anterior 0–2mm and 2–6mm regions between the groups (p=0.081, p=0.054,respectively). However, the difference between the groups in the central (0-2mm, 2-6mm) and posterior (0-2mm, 2-6mm) area was statistically significant (p<0.001, p=0.009, p=0.009, p<0.001, respectively). In addition, the difference between the groups in the total 0-2mm and 2-6mm area was statistically significant (p=0.001, p<0.001, respectively). Conclusions: Total HOA values were higher in amblyopic eyes compared to the fellow normal eye. Central and posterior corneal densitometry values were decreased in patients’ amblyopic eyes compared to their fellow eye. This may be related to some compensation mechanisms and/or microstructural changes in the cornea

Özet

Objective: To compare corneal aberrations and densitometry values in children with amblyopia due to anisometropic hyperopia with those of healthy children. Methods: This study included 173 children with amblyopia due to hyperopic anisometropia in one eye and 173 children with both healthy eyes. The amblyopic eye (Group 1) and the fellow normal eye (Group 2) of the amblyopic patients and the right eye of the healthy control group (Group 3) were evaluated. Of the corneal aberration and corneal densitometry (CD)measured using Scheimpflug corneal topography values were noted. Results: While there was a significant difference in total root mean square (RMS), higher-order aberration (HOA) RMS, coma horizontal, trefoil horizontal and spherical aberration values between the groups (p<0.001, p<0.001, p<0.001, p<0.001, p=0.008, respectively), there was no difference between coma vertical and trefoil oblique values (p=0.076, p=0.074, respectively). There was no significant difference in terms of CD values in the anterior 0–2mm and 2–6mm regions between the groups (p=0.081, p=0.054,respectively). However, the difference between the groups in the central (0-2mm, 2-6mm) and posterior (0-2mm, 2-6mm) area was statistically significant (p<0.001, p=0.009, p=0.009, p<0.001, respectively). In addition, the difference between the groups in the total 0-2mm and 2-6mm area was statistically significant (p=0.001, p<0.001, respectively). Conclusions: Total HOA values were higher in amblyopic eyes compared to the fellow normal eye. Central and posterior corneal densitometry values were decreased in patients’ amblyopic eyes compared to their fellow eye. This may be related to some compensation mechanisms and/or microstructural changes in the cornea.

🔖

Cite This Article

Öncül, H. (2021). Evaluation of Corneal Optic Quality in Amblyopia. Dicle Tıp Dergisi, Cilt: 48 Sayı: 1, 1–8. https://doi.org/10.5798/dicletip.887261

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Barrett BT, Bradley A, McGraw PV. Understandingthe neural basis of amblyopia. Neuroscientist. 2004; 10: 106-17.
  2. Carlton J, Kaltenthaler E. Amblyopia and quality oflife: a systematic review. Eye (Lond). 2011; 25: 403-13.