Journals / Experimed / 2026 / Volume: 16 Issue: 2

Clinical Outcomes of Cable Grip Plate–Cable Grip Constructs in the Management of Femoral Intertrochanteric Fractures

Ömer Yonga(Yeditepe University, Faculty of Medicine, Department of Orthopedics and Traumatology)0000-0002-3872-8836
Behic Celik(Yeditepe University, Faculty of Medicine, Department of Orthopedics and Traumatology)0009-0001-1779-4500
Faik Altintaş(Yeditepe University, Faculty of Medicine, Department of Orthopedics and Traumatology)0000-0002-5242-250X
Journal
Experimed
Pages
—
Publication Date
2026-08-28
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Despite longer operative time and increased blood loss, cable grip plate fixation was associated with better functional recovery and fewer late complications, supporting its use for greater trochanter stabilization in this population.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: This study aimed to compare functional outcomes, complication rates, and perioperative parameters of Cable Grip Plate and Grip Cable techniques for greater trochanter fixation in elderly patients undergoing partial hip replacement for intertrochanteric femur fractures.
📊
Key Findings & Data:Materials and Methods: This study included 82 patients aged > 60 years treated between January 2020 and December 2023.
💡
Conclusion & Impact:Conclusion: Despite longer operative time and increased blood loss, cable grip plate fixation was associated with better functional recovery and fewer late complications, supporting its use for greater trochanter stabilization in this population.
🔬Design:Research Article
📍Scope:2020 Verileri
⚙️Variables:Intertrochanteric fractures · Hip arthroplasty · Cable grip system

Abstract

Objective: This study aimed to compare functional outcomes, complication rates, and perioperative parameters of Cable Grip Plate and Grip Cable techniques for greater trochanter fixation in elderly patients undergoing partial hip replacement for intertrochanteric femur fractures. Materials and Methods: This study included 82 patients aged > 60 years treated between January 2020 and December 2023. Greater trochanter fixation was performed using a cable grip plate (n=45) or a grip cable system (n=37). Demographics, operative time, intraoperative blood loss, early and late complications, revision rates, functional outcomes (Harris Hip Score (HHS), Parker Mobility Score (PMS), Visual Analog Scale (VAS)), and walking aid use were compared between groups. Results: Operative time and blood loss were significantly higher in the cable grip plate group (p=0.001 and p<0.001, respectively). Nevertheless, this group demonstrated superior functional outcomes, including higher HHS (82.7 ± 4.8 vs 79.6 ± 5.5, p=0.008), improved PMS (p=0.006), lower VAS scores (p=0.032), and earlier return to activities of daily living (p=0.009). Late complications were more frequent in the Grip Cable group (p=0.030), whereas revision rates and mortality were similar. Conclusion: Despite longer operative time and increased blood loss, cable grip plate fixation was associated with better functional recovery and fewer late complications, supporting its use for greater trochanter stabilization in this population.

🔖

Cite This Article

Yonga, Ö., Celik, B., Altintaş, F. (2026). Clinical Outcomes of Cable Grip Plate–Cable Grip Constructs in the Management of Femoral Intertrochanteric Fractures. Experimed, Volume: 16 Issue: 2. https://doi.org/10.26650/experimed.1949327

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (20)

  1. Mei XY, Gong YJ, Safir OA, Gross AE, Kuzyk PR. Fixation options following greater trochanteric osteotomies and fractures in total hip arthroplasty: a systematic review. JBJS Rev 2018 6(6): e4. google scholar
  2. Sundaram K, Siddiqi A, Kamath AF, Higuera CA. Trochanteric osteotomy in revision total hip arthroplasty. EFORT Open Rev 2020 5: 477--85. google scholar
  3. Sheridan GA, Galbraith A, Kearns SR. Extended trochanteric osteotomy fixation for femoral stem revision in periprosthetic fractures: Dall--Miles plate versus cables. Eur J Orthop Surg Traumatol 2018 28: 471--6. google scholar
  4. Kim IS, Pansey N, Kansay RK, Yoo JH, Lee HY, Chang JD. Greater trochanteric reattachment using the third-generation cable plate system in revision total hip arthroplasty. J Arthroplasty 2017 32: 1965--9. google scholar
  5. Koyama K, Higuchi F, Kubo M, Okawa T, Inoue A. Reattachment of the greater trochanter using the Dall-Miles cable grip system in revision hip arthroplasty. J Orthop Sci 2001 6(1): 22--7. google scholar
  6. Collado A, Arvinius C, Serrano L, Otero J, Moro E, Marco F. Cerclage wire fixation of trochanteric osteotomies in complex hip revision: comparison with cable-plate fixation. Hip Int 2021 32(5): 672--6. google scholar
  7. Ogur HU, Tuhanioğlu U, Seyfettinoğlu F, Çiloğlu O, Uslu H, Fidan E. Clinical and functional results of trochanter major fixation in elderly patients undergoing hip arthroplasty for unstable pertrochanteric fractures. J Orthop Trauma Surg Relat Res 2019 14(2): 1-8. google scholar
  8. Speranza A, Massafra C, Pecchia S, Di Niccolo R, Iorio R, Ferretti A. Metallic versus non-metallic cerclage cable systems in periprosthetic hip fracture treatment. J Clin Med 2022 11(6): 1608. google scholar
  9. Nho JH, Seo GW, Kang TW, Jang BW, Park JS, Suh YS. Bipolar hemiarthroplasty in unstable intertrochanteric fractures with an effective wiring technique. Hip Pelvis 2023 35(2): 99--107. google scholar
  10. Tang J, Wu T, Shao H, Zhou Y. Greater trochanter fixation with a claw plate and cable system in complex primary and revision total hip arthroplasty: long-term follow-up. Int Orthop 2022 46: 2553--60. google scholar
  11. Dall DM, Miles AW. Re-attachment of the greater trochanter: the use of the trochanter cable-grip system. J Bone Joint Surg Br 1983 65(1): 55--9. google scholar
  12. Kelley SS, Johnston RC. Debris from cobalt-chrome cable may cause acetabular loosening. Clin Orthop Relat Res 1992 285: 140--6. google scholar
  13. Altenburg AJ, Callaghan JJ, Yehyawi TM, Pedersen DR, Liu SS, Leinen JA, et al. Cemented total hip replacement cable debris and acetabular construct durability. J Bone Joint Surg Am 2009 91(7): 1664-70. google scholar
  14. Ricciardi BF, Nodzo SR, Oi K, Lee YY, Westrich GH. Radiographic outcomes of cable-plate versus cable-grip fixation in periprosthetic fractures of the proximal femur. Hip Int 2017 27(6): 584--8. google scholar
  15. Ohly NE, Whitehouse MR, Duncan CP. Periprosthetic femoral fractures in total hip arthroplasty. Hip Int 2014 24(6): 556--67. google scholar
  16. Liu P, Jin D, Zhang C, Gao Y. Revision surgery due to failed internal fixation of intertrochanteric femoral fracture: current state of the art. BMC Musculoskelet Disord 2020 21: 573. google scholar
  17. Faldini C, Grandi G, Romagnoli M, Pagkrati S, Digennaro V, Faldini O, et al. Surgical treatment of unstable intertrochanteric fractures by bipolar or total hip replacement in elderly osteoporotic patients. J Orthop Traumatol 2006 7: 117--21. google scholar
  18. Kilci O, Un C, Sacan O, Gamli M, Baskan S, Baydar M, et al. Postoperative mortality after hip fracture surgery: a 3-year follow-up. PLoS One 2016 11: e0162097. google scholar
  19. Nijmeijer WS, Folbert EC, Vermeer M, Slaets JPJ, Hegeman JH. Prediction of early mortality following hip fracture surgery in frail elderly patients: the Almelo Hip Fracture Score (AHFS). Injury 2016 47(10): 2138--43. google scholar
  20. Kristensen MT, Foss NB, Ekdahl C, Kehlet H. Prefracture functional level evaluated by the New Mobility Score predicts in-hospital outcome after hip fracture surgery. Acta Orthop 2010 81(3): 296--302. google scholar