Journals / European Oral Research / 2023 / Cilt: 57 Sayı: 3

The effects of various scaling instruments on the surface roughness of monolithic zirconia and lithium disilicate

Pages
133–137
Publication Date
2023-09-28
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Piezoelectric scalers with plastic tips cause less deterioration on monolithic zirconia and lithium disilicate surfaces when compared to stainless-steel hand curettes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: This in vitro study aims to evaluate the effects of plastic piezoelectric maintenance tips on the surface roughness of monolithic lithium disilicate and zirconia.
📊
Key Findings & Data:Materials and Methods: Fifty-four lithium disilicate and 54 zirconia disks were prepared with CAD/CAM.
💡
Conclusion & Impact:Conclusion: Piezoelectric scalers with plastic tips cause less deterioration on monolithic zirconia and lithium disilicate surfaces when compared to stainless-steel hand curettes.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:instrumentation · curette · plastic

Abstract

Purpose: This in vitro study aims to evaluate the effects of plastic piezoelectric maintenance tips on the surface roughness of monolithic lithium disilicate and zirconia. Materials and Methods: Fifty-four lithium disilicate and 54 zirconia disks were prepared with CAD/CAM. On each material, scaling with a stainless-steel curette or with a piezoelectric device using either a steel or plastic tip was conducted. The surface roughness of the materials before and after the instrumentation was measured with a profilometer. The changes in roughness of the materials according to the scaling methods were analyzed with generalized linear models. Mann-Whitney U with Bonferroni correction was used for between-group comparisons. Results: The instruments caused surface alterations on both materials (p=0.001), while the roughness change of lithium disilicate and zirconia specimens did not demonstrate any statistically significant difference with each other (p=0.274). However, the curette was found to cause significantly more (p=0.019) roughness change (0.259 ±0.405) on the specimens than the piezoelectric plastic tip (0.060 ±0.238). Conclusion: Piezoelectric scalers with plastic tips cause less deterioration on monolithic zirconia and lithium disilicate surfaces when compared to stainless-steel hand curettes.

🔖

Cite This Article

YILMAZ, M., DEMİR, E., OLCAY, E. O. (2023). The effects of various scaling instruments on the surface roughness of monolithic zirconia and lithium disilicate. European Oral Research, Cilt: 57 Sayı: 3, 133–137. https://ajindex.com/articles/1016023

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Sbordone L, Ramaglia L, Gulletta E, Iacono V. Recolonization of the subgingival microflora after scaling and root planing in human periodontitis. J Periodontol 1990
  2. 579–84. google scholar Ioannou I, Dimitriadis N, Papadimitriou K, Sakellari D, Vouros I, Konstantinidis A. Hand instrumentation versus ultrasonic debridement in the treatment of chronic periodontitis: a randomized clinical and microbiological trial. J Clin Periodontol 2009
  3. 132–41. google scholar Leknes KN. The Influence of Anatomic and Iatrogenic Root Surface Characteristics on Bacterial Colonization and Periodontal Destruction: A Review. J Periodontol 1997
  4. 507–16. google scholar Blatz MB, Conejo J. The current state of chairside digital dentistry and materials. Dent Clin 2019
  5. 175–97. google scholar Nejatidanesh F, Savabi G, Amjadi M, Abbasi M, Savabi O. Five year clinical outcomes and survival of chairside CAD/CAM ceramic laminate veneers—a retrospective study. J Prosthodont Res 2018
  6. 462–7. google scholar Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all‐ceramic three‐unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005
  7. 174–9. google scholar Belli R, Wendler M, de Ligny D, Cicconi MR, Petschelt A, Peterlik H, et al. Chairside CAD/CAM materials. Part 1: Measurement of elastic constants and microstructural characterization. Dent Mater 2017
  8. 84–98. google scholar Raigrodski AJ, Chiche GJ. The safety and efficacy of anterior ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2001
  9. 520–5. google scholar Albakry M, Guazzato M, Swain MV. Biaxial flexural strength, elastic moduli, and x-ray diffraction characterization of three pressable all-ceramic materials. J Prosthet Dent 2003
  10. 374–80. google scholar Vigolo P, Motterle M. An in vitro evaluation of zirconia surface roughness caused by different scaling methods. J Prosthet Dent 2010
  11. 283–7. google scholar Albashaireh ZSM, Ghazal M, Kern M. Two-body wear of different ceramic materials opposed to zirconia ceramic. J Prosthet Dent 2010
  12. 105–13. google scholar Tong H, Tanaka CB, Kaizer MR, Zhang Y. Characterization of three commercial Y-TZP ceramics produced for their high-translucency, high-strength and high-surface area. Ceram Int 2016
  13. 1077–85. google scholar Elsaka SE. Optical and mechanical properties of newly developed monolithic multilayer zirconia. J Prosthodont 2019
  14. e279–84. google scholar Stawarczyk B, Mandl A, Liebermann A. M