Dergiler / Üroloji Bülteni / 1999 / Cilt: 10 - Sayı: 3

Unilateral testis torsiyonunun kontralateral testis kan akımına etkileri: Köpeklerde deneysel bir çalışma

The effects of unilateral testicular torsion on the blood flow of contralateral testis: An experimental study on dogs

Sayfa
141–145
DOI
—

Özet

Testis torsiyonunun kontralateral testis kan akimi uzerine etkilerini arastirmak. Gereg ve Yontem: Kontrol (yalanci operasyon) ve torsiyon gruplanni igeren 2 grup eriskin erkek kopek kullanildi. Her iki testisin kan akimi torsiyon 6nces(ye sonrasmda renkli Doppler ultrasonografi ile degerlendirildi. Qalisma sonundabilateral or§iektomi yapilarak testisler histopatolojik incelemeye alindi. Bulgular: Torsiyon sonrasi kontralateral testislerde renkli Doppler ultrasonografi ile tespit edilen tepe sistolik hizlar, diyastol sonu hizlar ve rezistif indeks degerleri torsiyon oncesi ipsilateral, kontralateral ve kontrol grubunun her iki testisinde olgulen degerlerden istatistiksel olarak farkli degildi (p> 0.05). Kontralateral testislerde histopatolojik degisiklikler gb'rulmemesine ragmen, yalanci operasyon grubunun manipule*edilen testislerinde minimal odem ve konjesyon saptandi. Kontrol grubu ile karsilastmldigmda gali§ma grubunun kontralateral testislerinin kan akiminda anlamli degisiklik bulunamadi. Sonup: Unilateral testikuler torsiyon renkli Doppler ultrasonografi ile tayin edilen kontralateral testikuler-kan akim hizini etkilememektedir.

Abstract

To investigate the effects of unilateral testicular torsion on the blood flow of contralateral testis. Materials and Methods: We studied adult male dogs in 2 groups as control (sham operation) and torsion. Before and after the torsion operation blood flows of both testes were determined by colour Doppler ultrasonography. Bilateral orchiectomy tvas performed at the end of the study and histopathological changes were noted. Results: Peak sistolic velocity, end diastolic velocity, and resistive index values obtained after testicular torsion of the contralateral testes were not significantly different from those obtained from ipsilateral and contralateral testes before torsion, and from both testes in controls (p> 0.05). Although there zuere no histopathological changes in the contralateral testes, minimal oedema and congestion were observed in manipulated testes of the sham operation group. Blood flows in the contralateral testes of the study group were not significantly different than those in the control group. Conclusion: Unilateral testicular torsion does not effect contralateral testicular blood flow as detected by colour Doppler ultrasonography.

Anahtar kelimeler: Ultrasonografi, doppler, renkli,Orşiektomi,Kan akım hızı,Hastalık modelleri, hayvan,Spermatik kord torsiyonu,Testis,Köpekler,Bölgesel kan akımı,Testis hastalıkları