Dergiler / International Journal of Intelligent Systems and Applications in Engineering / 2016 / Cilt: 4 Sayı: Special Issue-1

A Multistage Deep Belief Networks Application on Arrhythmia Classification

Sayfa
222–228
Yayın Tarihi
2016-12-25
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The proposed DBN-based multistage arrhythmia classification model has discriminated five types of heartbeats with a high accuracy rate of 96.10%.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:An electrocardiogram (ECG) is a biomedical signal type that determines the normality and abnormality of heart beats using the electrical activity of the heart and has a great importance for cardiac disorders.
📊
Temel Bulgular & Veri:The multistage DBN model classified the MIT-BIH Arrhythmia Database heartbeats into 5 main groups defined by ANSI/AAMI standards.
💡
Sonuç & Katkı:The proposed DBN-based multistage arrhythmia classification model has discriminated five types of heartbeats with a high accuracy rate of 96.10%.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Arrhythmia · Deep Belief Networks · DBN

Abstract

An electrocardiogram (ECG) is a biomedical signal type that determines the normality and abnormality of heart beats using the electrical activity of the heart and has a great importance for cardiac disorders. The computer-aided analysis of biomedical signals has become a fabulous utilization method over the last years. This study introduces a multistage deep learning classification model for automatic arrhythmia classification. The proposed model includes a multi-stage classification system that uses ECG waveforms and the Second Order Difference Plot (SODP) features using a Deep Belief Network (DBN) classifier which has a greedy layer wise training with Restricted Boltzmann Machines algorithm. The multistage DBN model classified the MIT-BIH Arrhythmia Database heartbeats into 5 main groups defined by ANSI/AAMI standards. All ECG signals are filtered with median filters to remove the baseline wander. ECG waveforms were segmented from long-term ECG signals using a window with a length of 501 data points (R wave centered). The extracted waveforms and elliptical features from the SODP are utilized as the input of the model. The proposed DBN-based multistage arrhythmia classification model has discriminated five types of heartbeats with a high accuracy rate of 96.10%.

🔖

Bu Makaleye Atıf Yap

ALTAN, G., KUTLU, Y., ALLAHVERDI, N. (2016). A Multistage Deep Belief Networks Application on Arrhythmia Classification. International Journal of Intelligent Systems and Applications in Engineering, Cilt: 4 Sayı: Special Issue-1, 222–228. https://ajindex.com/articles/995976

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. WHO. The top 10 causes of death y.y. http://www.who.int/mediacentre/factsheets/fs310/en/ (access: 07 August 2016).
  2. Webster JG. Medical Instrumentation, Application and Design. 4th baskı. Boston: Houghtoon Mifflin Company; 1978.
  3. Yeh YC, Chiou CW, Lin HJ. Analyzing ECG for cardiac arrhythmia using cluster analysis. Expert Syst Appl 2012;39:1000–10. doi:10.1016/j.eswa.2011.07.101. Hamilton P. Open source ECG analysis. Comput Cardiol 2002;29:101–4. doi:10.1109/CIC.2002.1166717. Ge D, Srinivasan N, Krishnan SM. Cardiac arrhythmia classification using autoregressive modeling. Biomed Eng Online 2002;1:5. doi:10.1186/1475-925X-1-5.
  4. Israel SA, Irvine JM, Cheng A, Wiederhold MD, Wiederhold BK. ECG to identify individuals. Pattern Recognit 2005;38:133–42. doi:10.1016/j.patcog.2004.05.014. Plataniotis KN, Hatzinakos D, Lee JKM. ECG Biometric Recognition Without Fiducial Detection. 2006 Biometrics Symp. Spec. Sess. Res. Biometric Consort. Conf., IEEE; 2006, s. 1–6. doi:10.1109/BCC.2006.4341628. Bengio Y, Delalleau O. Justifying and generalizing contrastive divergence. Neural Comput 2009;21:1601–21. doi:10.1162/neco.2008.11-07-647.
  5. Moody GB, Mark RG. The impact of the MIT-BIH arrhythmia database. IEEE Eng Med Biol Mag y.y.;20:45–50.
  6. Kutlu Y, Kuntalp D. A multi-stage automatic arrhythmia recognition and classification system. Comput Biol Med 2011;41:37–45. doi:10.1016/j.compbiomed.2010.11.003. Rajendra Acharya U, Suri JS, Spaan JAE, Krishnan SM. Advances in cardiac signal processing. 2007. doi:10.1007/978-3-540-36675-1. M. Gabriel Khan. Rapid ECG Interpretation(Contemporary Cardiology). 3rd editio. Humana Press; 2007. Dr Patrick Davey. ECG (electrocardiogram). NetDoctor 2011:1–4. Kara S. Sensing of ECG signals and Imaging at the Computer in Real Time. Erciyes University, 1991.
  7. Yayik A, Kutlu Y. Konjestif kalp yetmezliǧinin ikinci-derece fark harita grafiǧi ile topografik analizi ve teşhisi. 2014 22nd Signal Process. Commun. Appl. Conf. SIU 2014 - Proc., 2014, s. 540–3. doi:10.1109/SIU.2014.6830285. Altan G, Kutlu Y. ECG based Human identification using Logspace Grid Analysis of Second Order Difference Plot. Signal Process Commun Appl Conf 2015:1288–91.
  8. Bengio Y, Lamblin P, Popovici D, Larochelle H. Greedy Layer-Wise Training of Deep Networks. Adv Neural Inf Process Syst 2007;19:153. doi:citeulike-article-id:4640046. Yan Y, Qin X, Wu Y, Zhang N, Fan J, Wang L. A restricted Boltzmann machine based two-lead electrocardiography classification. 2015 IEEE 12th Int Conf Wearabl