Dergiler / Gazi University Journal of Science Part A: Engineering and Innovation / 2023 / Cilt: 10 Sayı: 3

Investigation of Surface Dose Accuracy of Two Dose Calculation Algorithms Using Thermoluminescent Dosimeters

Sayfa
353–360
Yayın Tarihi
2023-09-29
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

AAA and PBC algorithm users are advised to be more careful about surface dose calculation.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Accurate estimation of the surface dose in radiotherapy is very important in reducing skin reactions.
📊
Temel Bulgular & Veri:The phantom surface consisted of an adhesive bolus for the adhesion of TLDs. 121 TLDs were placed 1 cm apart on the bolus surface.
💡
Sonuç & Katkı:AAA and PBC algorithm users are advised to be more careful about surface dose calculation.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Surface Dose · Thermoluminescent Dosimetry · Algorithm

Abstract

Accurate estimation of the surface dose in radiotherapy is very important in reducing skin reactions. This study aims to evaluate the accuracy of two different treatment planning algorithms in calculating the surface dose in a specially designed phantom using thermoluminescent dosimetry (TLD). In this study, a special phantom was designed for surface dose measurement. The phantom surface consisted of an adhesive bolus for the adhesion of TLDs. 121 TLDs were placed 1 cm apart on the bolus surface. In TPS, irradiation plans were created at different fields and source-surface distances (SSD). Dose calculations were made with Anisotropic Algorithm algorithms (AAA) and Pencil Beam Convolution (PBC) algorithms for all plans. The mean dose was measured for each point. For each of the 4x4, 6x6, 8x8, 10x10, and 12x12 cm2 domains, the TLDs within the domain were approximately 1 cm inward from the edge. To measure the effect of SSD on surface dose, the isocenter point was located at depths of 0 cm, 2.5 cm and 5.0 cm, respectively. The surface dose at each depth was measured with TLDs. The doses calculated by the AAA and PBC algorithms were compared with the doses measured by TLDs. The AAA algorithm overestimates the surface dose by 4% compared to the TLD measurement for the 4x4 field. The surface dose calculation of the PBC algorithm was found to be high when compared to TLD measurements for all SSDs and fields. There was a significant difference between the PBC algorithm dose calculation and TLD measurements in all fields and SSDs (p<0.001). It was observed that the AAA algorithm performed better in calculating the surface dose than the PBC algorithm. AAA and PBC algorithm users are advised to be more careful about surface dose calculation.

🔖

Bu Makaleye Atıf Yap

GÜL, O. V. (2023). Investigation of Surface Dose Accuracy of Two Dose Calculation Algorithms Using Thermoluminescent Dosimeters. Gazi University Journal of Science Part A: Engineering and Innovation, Cilt: 10 Sayı: 3, 353–360. https://ajindex.com/articles/966134

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Aydemir, G. A., Akay, D., Tataroğlu, A., & Ocak, S. B. (2023). Electrical and optical properties of p-Si based structures with lead oxide interfaces. Materials Science and Engineering: B, 294, 116552. doi:10.1016/j.mseb.2023.116552 Cao, Y., Yang, X., Yang, Z., Qiu, X., Lv, Z., Lei, M., Liu, G., Zhang, Z., & Hu, Y. (2017). Superficial dose evaluation of four dose calculation algorithms. Radiation Physics and Chemistry, 137, 23-28. doi:10.1016/j.radphyschem.2016.02.032 Chakarova, R., Gustafsson, M., Back, A., Drugge, N., Palm, Å., Lindberg, A., & Berglund, M. (2012). Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries. Radiotherapy and Oncology, 102(1), 102-107. doi:10.1016/j.radonc.2011.06.021 Córdoba, E. E., Lacunza, E., & Güerci, A. M. (2021). Clinical factors affecting the determination of radiotherapy-induced skin toxicity in breast cancer. Radiation Oncology Journal, 39(4), 315-323. doi:10.3857/roj.2020.00395 Danckaert, W., Ost, P., & De Wagter, C. (2023). Accuracy and reliability of a commercial treatment planning system in nontarget regions in modern prostate radiotherapy. Journal of Applied Clinical Medical Physics, 24(8). doi:10.1002/acm2.14003 Guardiola, C., Bachiller‐Perea, D., Kole, E. M. M., Fleta, C., Quirion, D., De Marzi, L., & Gómez, F. (2022). First experimental measurements of 2D microdosimetry maps in proton therapy. Medical Physics, 50(1), 570-581. doi:10.1002/mp.15945 Lejosne, S., Allison, H. J., Blum, L. W., Drozdov, A. Y., Hartinger, M. D., Hudson, M. K., Jaynes, A. N., Ozeke, L., Roussos, E., & Zhao, H. (2022). Differentiating Between the Leading Processes for Electron Radiation Belt Acceleration. Frontiers in Astronomy and Space Sciences, 9. doi:10.3389/fspas.2022.896245 Mahur, M., Singh, M., Semwal, M., & Gurjar, O. (2022). Evaluation of surface dose calculations using monaco treatment planning system in an indigenously developed head and neck phantom. Medical Journal of Dr. D.Y. Patil Vidyapeeth. doi:10.4103/mjdrdypu.mjdrdypu_827_21 Matsumoto, T., Toya, R., Shimohigashi, Y., Watakabe, T., Matsuyama, T., Saito, T., Fukugawa, Y., Kai, Y., & Oya, N. (2021). Plan Quality Comparisons Between 3D-CRT, IMRT, and VMAT Based on 4D-CT for Gastric MALT Lymphoma. Anticancer Research, 41(8), 3941-3947. doi:10.21873/anticanres.15190 Mowery, M. L., & Singh, V. (2023). X-ray Production Technical Evaluation. StatPearls. Treasure Island (F