Reliability, Concurrent Validity, and Minimal Detectable Change of a Smartphone Application for Measuring Thoracic Kyphosis

Sayfa
511–516
Yayın Tarihi
2023-09-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

More than 9 degrees in the value of the thoracic kyphosis angle measured by the smartphone application can be considered as a true change.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: To assess the intra- and inter-rater reliability and concurrent validity, and to estimate minimal detectable change of a smartphone application for measuring thoracic kyphosis angle.
📊
Temel Bulgular & Veri:Methods: A total of 80 healthy university students were evaluated.
💡
Sonuç & Katkı:More than 9 degrees in the value of the thoracic kyphosis angle measured by the smartphone application can be considered as a true change.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Reliability · validity · kyphosis

Abstract

Objective: To assess the intra- and inter-rater reliability and concurrent validity, and to estimate minimal detectable change of a smartphone application for measuring thoracic kyphosis angle. Methods: A total of 80 healthy university students were evaluated. Two raters measured the thoracic kyphosis angle using a digital inclinometer and the smartphone application. Intra- and inter-rater reliability were assessed using the intraclass correlation coefficient (ICC) with 95% confidence interval. The standard error of measurement (SEM) and the minimal detectable change at the 95% confidence level (MDC95) were also calculated. The concurrent validity between the digital inclinometer and the smartphone application was assessed by the linear regression analysis and Bland and Altman's 95% limits of agreement method. Results: The intra- and inter-rater reliability were excellent for the digital inclinometer and the smartphone application (ICC > 0.75). The SEM values for the digital inclinometer and the smartphone application were close together. The MDC95 values for the smartphone application were 5.11 and 6.30 degrees, and 9.02 degrees for intra- and inter-rater, respectively. The digital inclinometer and the smartphone application showed a positive correlation (R2 = 0.85). The Bland-Altman plot showed a good agreement between the instruments. Conclusion: The smartphone application used in this study is a cost-effective, practical, reliable, and valid instrument for measuring the thoracic kyphosis angle. More than 9 degrees in the value of the thoracic kyphosis angle measured by the smartphone application can be considered as a true change.

🔖

Bu Makaleye Atıf Yap

ŞAHİNOĞLU, E., ERGİN, G., BAKIRHAN, S., ÜNVER, B. (2023). Reliability, Concurrent Validity, and Minimal Detectable Change of a Smartphone Application for Measuring Thoracic Kyphosis. Clinical and Experimental Health Sciences, Cilt: 13 Sayı: 3, 511–516. https://ajindex.com/articles/961647

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (5)

  1. Perriman DM, Scarvell JM, Hughes AR, Ashman B, Lueck CJ, Smith PN. Validation of the flexible electrogoniometer for measuring thoracic kyphosis. Spine (Phila Pa 1976) 2010;35(14):E633–640. DOI:10.1097/BRS.0b013e3181d13039 Barrett E, O’Keeffe M, O’Sullivan K, Lewis J, McCreesh K. Is thoracic spine posture associated with shoulder pain, range of motion and function? A systematic review. Man Ther 2016;26:38–46. DOI:10.1016/j.math.2016.07.008. Sinaki M, Brey RH, Hughes CA, Larson DR, Kaufman KR. Balance disorder and increased risk of falls in osteoporosis and kyphosis: Significance of kyphotic posture and muscle strength. Osteoporos Int 2005;16(8):1004–1010. DOI: 10.1007/s00198- 004-1791-2
  2. Kim DY, Moon ES, Park JO, Chong HS, Lee HM, Moon SH, Kim SH, Kim HS. The thoracic lordosis correction improves sacral slope and walking ability in neuromuscular scoliosis. Clin Spine Surg 2016;29(8):E413–E420. DOI:10.1097/BSD.0b013e318294368e Ishikawa Y, Miyakoshi N, Hongo M, Kasukawa Y, Kudo D, Shimada Y. Relationships among spinal mobility and sagittal alignment of spine and lower extremity to quality of life and risk of falls. Gait Posture 2017;53:98–103. DOI:10.1016/j.gaitpost.2017.01.011 Kado DM, Lui L-Y, Ensrud KE, Fink HA, Karlamangla AS, Cummings SR. Hyperkyphosis predicts mortality independent of vertebral osteoporosis in older women. Ann Intern Med. 2009;150(10):681-687.DOI:10.7326/0003-4819-150-10- 200905190-00005
  3. Barrett E, McCreesh K, Lewis J. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: A systematic review. Man Ther. 2014;19(1):10–17. DOI: 10.1016/j.math.2013.09.003. Briggs AM, Wrigley TV, Tully EA, Adams PE, Greig AM, Bennell KL. Radiographic measures of thoracic kyphosis in osteoporosis: Cobb and vertebral centroid angles. Skeletal Radiol. 2007;36(8):761–767.DOI: 10.1007/s00256-007-0284-8.
  4. Lundon KM, Li AM, Bibershtein S. Interrater and intrarater reliability in the measurement of kyphosis in postmenopausal women with osteoporosis. Spine (Phila Pa 1976) 1998;23(18):1978–1985. DOI:10.1097/00007632-199809150-00013.
  5. Greendale GA, Nili NS, Huang MH, Seeger L, Karlamangla AS. The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle. Osteoporos Int. 2011;22(6):1897–1905. DOI: 10.1007/s00198-010-1422-z Roghani T, Khalkhali Zavieh M, Rahimi A, Talebian S, Dehghan Manshadi F, Akbarzadeh Baghban A, King N,Katzman W. The Reliability of standi