Dergiler / Journal of Thermal Engineering / 2023 / Cilt: 9 Sayı: 4

Effect of operating parameters on the performance of rotary desiccant wheel energized by PV/T collectors

Sayfa
998–997
Yayın Tarihi
2023-08-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Finally, considering the whole system, it was concluded that the optimum regeneration air temperature for the performance parameters is 60°C.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The main energy input of a desiccant air conditioning system is the low-quality thermal ener-gy required for regeneration, which can be obtained from waste heat, geothermal resources or solar energy.
📊
Temel Bulgular & Veri:In this study, parametric analyzes were performed to investigate the effect of regeneration temperature and air frontal velocity on the tempera-ture and dehumidification performance of a solid silica-gel desiccant wheel and on the wa-ter-cooled PV/T collectors used to provide the regeneration thermal energy.
💡
Sonuç & Katkı:Finally, considering the whole system, it was concluded that the optimum regeneration air temperature for the performance parameters is 60°C.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Keywords: Desiccant Air-Conditioning · Rotary Desiccant Wheel · Silica-gel

Abstract

The main energy input of a desiccant air conditioning system is the low-quality thermal ener-gy required for regeneration, which can be obtained from waste heat, geothermal resources or solar energy. Regeneration thermal energy can be produced as well as energizing components such as fans, pumps, auxiliary air heaters, and control elements of the system by using pho-tovoltaic-thermal solar collectors (PV/T). In this study, parametric analyzes were performed to investigate the effect of regeneration temperature and air frontal velocity on the tempera-ture and dehumidification performance of a solid silica-gel desiccant wheel and on the wa-ter-cooled PV/T collectors used to provide the regeneration thermal energy. The regeneration temperature was varied between 50 and 70°C, and air frontal velocity between 1.3 and 4.1 m/s. The analyzes show that the dehumidification efficiency increases from 13.94% to 33.04% as regeneration temperature increased from 50°C to 70°C at 1.3 m/s air frontal velocity at which dehumidification efficiency is maximum. At 4.1 m/s air frontal velocity, the required regener-ation thermal energy is maximum and increases from 49.64 kW to 132.48 kW at the same re-generation temperature change. The low regeneration temperature resulted in desirable latent performance and undesirable sensible heat transfer performance in DEW. Finally, considering the whole system, it was concluded that the optimum regeneration air temperature for the performance parameters is 60°C.

🔖

Bu Makaleye Atıf Yap

OLMUŞ, U., GÜZELEL, Y. E., ÇERÇI, K. N., BÜYÜKALACA, O. (2023). Effect of operating parameters on the performance of rotary desiccant wheel energized by PV/T collectors. Journal of Thermal Engineering, Cilt: 9 Sayı: 4, 998–997. https://ajindex.com/articles/955542

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. REFERENCES [1] Guo J, Bilbao JI, Sproul AB. A novel solar cooling cycle – A ground coupled PV/T desiccant cooling (GPVTDC) system with low heat source temperatures. Renewable Energy 2020
  2. 12731284. [CrossRef] [2] Fan H, MacGill IF, Sproul AB. Statistical analysis of driving factors of residential energy demand in the greater Sydney region, Australia. Energy Build 2015
  3. 925. [CrossRef] [3] Rahman S, Said Z, Issa S. Performance evaluation and life cycle analysis of new solar thermal absorption air conditioning system. Energy Rep 2020
  4. 673679. [CrossRef] [4] Temiz M, Dincer I. A unique bifacial PV and hydrogen-based cleaner energy system with heat recovery for data centers. Appl Therm Eng 2022
  5. 118102. [CrossRef] [5] Kassas M, Hamanah WM, Al-Tamimi O, Sahin A, Yilbas BS, Ahmed CB. Operation of HVAC system for energy savings and economic analysis. J Therm Eng 2019
  6. 181197. [CrossRef] [6] Uçkan İ, Yılmaz T, Büyükalaca O. Effect of operation conditions on the second law analysis of a desiccant cooling system. Appl Therm Eng 2017
  7. 12561265. [CrossRef] [7] Heidarinejad G, Rayegan S, Pasdarshahri H. Dynamic simulation of a solar desiccant cooling system combined with a ground source heat exchanger in humid climates. J Build Eng 2020
  8. 101048. [8] Olmuş U, Güzelel YE, Pınar E, Özbek A, Büyükalaca O. Performance assessment of a desiccant air-conditioning system combined with dew-point indirect evaporative cooler and PV/T. Sol Energy 2022
  9. 566577. [CrossRef] [9] Speerforck A, Ling J, Aute V, Radermacher R, Schmitz G. Modeling and simulation of a desiccant assisted solar and geothermal air conditioning system. Energy 2017
  10. 23212336. [CrossRef] [10] Shahsavari A, Akbari M. Potential of solar energy in developing countries for reducing energy-related emissions. Renew Sustain Energy Rev 2018
  11. 275291. [CrossRef] [11] Kashif A, Ali M, Sheikh NA, Vukovic V, Shehryar M. Experimental analysis of a solar assisted desiccant-based space heating and humidification system for cold and dry climates. Appl Therm Eng 2020
  12. 115371. [CrossRef] [12] Ma Z, Ren H, Lin W. A review of heating, ventilation and air conditioning technologies and innovations used in solar-powered net zero energy Solar Decathlon houses. J Clean Prod 2019
  13. 118158. [CrossRef] [13] Roy R, Kundu B. Optimum design analysis of a solar-assisted Libr/H2O absorption system with a flat-plate collector. J Therm Eng 2021
  14. 10561066. [CrossRef] [14] Fong KF, Chow TT, Lee CK, Lin Z, Chan LS