Dergiler / Tekstil ve Konfeksiyon / 2023 / Cilt: 33 Sayı: 1

Influence of Knitting Structure and Metal Wire Amount on Electromagnetic Shielding Effectiveness of Knitted Fabrics

Sayfa
37–44
Yayın Tarihi
2023-03-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It indicates that changing the knitting structure is more effective than changing the metal wire amount.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The aim of this study is to investigate the influence of knitting structure and metal wire amount on the electromagnetic shielding effectiveness (EMSE) of knitted fabrics comparatively.
📊
Temel Bulgular & Veri:The variance analysis results of the EMSE values reveal that the effect of knitting structure, metal wire type, metal wire amount, and incident wave frequency is highly significant.
💡
Sonuç & Katkı:It indicates that changing the knitting structure is more effective than changing the metal wire amount.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Conductive Composite Yarn · Knitted Fabric · Electromagnetic Shielding Effectiveness

Abstract

The aim of this study is to investigate the influence of knitting structure and metal wire amount on the electromagnetic shielding effectiveness (EMSE) of knitted fabrics comparatively. Single jersey, single pique, weft locknit, and cross miss fabrics involving stainless steel or copper wires were produced on a flat knitting machine. A free space measurement technique was used for the EMSE measurements in an anechoic chamber. The variance analysis results of the EMSE values reveal that the effect of knitting structure, metal wire type, metal wire amount, and incident wave frequency is highly significant. It was observed that fabrics with tuck and miss loop structures had higher EMSE values than single jersey fabrics. It was found that single pique fabrics had higher EMSE values than single jersey fabrics that contain twice as much metal wire. It indicates that changing the knitting structure is more effective than changing the metal wire amount.

🔖

Bu Makaleye Atıf Yap

TEZEL, S., KAVUŞTURAN, Y., VANDENBOSCH, G. A., VOLSKİ, V. (2023). Influence of Knitting Structure and Metal Wire Amount on Electromagnetic Shielding Effectiveness of Knitted Fabrics. Tekstil ve Konfeksiyon, Cilt: 33 Sayı: 1, 37–44. https://ajindex.com/articles/934232

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. World Health Organization - Electromagnetic Fields, What are the Electromagnetic Fields-, http://www.who.int/peh-emf/about/WhatisEMF/en/index1.html (accessed 25 August 2021)
  2. Europian Comission SCENIHR (Scientific Committee on Emerging and Newly Identified Health Risks). Opinion on potential health effects of exposure to electromagnetic fields (EMF) - Publications Office of the EU, https://op.europa.eu/en/publication-detail/-/publication/a67fe808-06bb-11e6-b713-01aa75ed71a1/language-en (2015, accessed 25 August 2021)
  3. Phillips JL, Singh NP, Lai H. Electromagnetic fields and DNA damage. Pathophysiology 2009; 16: 79–88
  4. Kim JH, Lee JK, Kim HG, et al. Possible effects of radiofrequency electromagnetic field exposure on central nerve system. Biomol Ther 2019; 27: 265–275
  5. Das A, Kothari VK, Kothari A, et al. Effect of various parameters on electromagnetic shielding effectiveness of textile fabrics. Indian J Fibre Text Res 2009; 34: 144–148
  6. Cheng KB, Lee ML, Ramakrishna S, et al. Electromagnetic Shielding Effectiveness of Stainless Steel/Polyester Woven Fabrics. Text Res J 2001; 71: 42–49
  7. IEEE-STD 299-1997: IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures. In: IEEE, https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=708260 (1997, accessed 26 August 2021)
  8. ASTM D4935-10: Standard Test Method for Measuring the Electromagnetic Shielding Effectiveness of Planar Materials. In: ASTM. 2010
  9. TS EN 50147-1: Anechoic chambers - Part 1: Shield attenuation measurement. In: TSE. 2005
  10. MIL-STD-285-1956: Method of Attenuation Measurement for Enclosures, Electromagnetic Shielding, for Electronic Test Purposes. In: MIL-STD. 1956
  11. Tezel S, Kavuşturan Y, Vandenbosch GA, et al. Comparison of Electromagnetic Shielding Effectiveness of Conductive Single Jersey Fabrics with Coaxial Transmission Line and Free Space Measurement Techniques. Text Res J 2014; 84: 461–476
  12. Palamutçu S, Özek A, Karpuz C, et al. Electrically Conductive Surfaces and Their Electromagnetic Shielding Efficency Measurements. Tekst ve Konfeksiyon 2010; 20: 199–207
  13. Çeken F, Kayacan Ö, Özkurt A, et al. The Electromagnetic Shielding Properties of Some Conductive Knitted Fabrics Produced on Single or Double Needle Bed of a Flat Knitting Machine. J Text Inst 2012; 103: 968–979
  14. Çeken F, Pamuk G, Kayacan O, et al. Electromagnetic Shielding Properties of Plain Knitted Fabrics Containing Conductive Yarns. J En