Dergiler / Environmental Research and Technology / 2019 / Cilt: 2 Sayı: 1

Detection of effective parameters in arsenic removal with capacitive deionization process and arsenic removal from wastewater

Sayfa
13–18
Yayın Tarihi
2019-03-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The removal efficiency of the MCDI process for arsenic was 94%.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Access to water is a problem the magnitude of which increases day by day.
📊
Temel Bulgular & Veri:In this study, using the optimum conditions which are operating times, flow rate, current, voltage, number of cycles, previously determined for Voltea brand MCDI, the removal of arsenic from the wastewater produced by Emet Bor Operation Directorate Espey Open Quarry and Concentrator Facility, Hisarcik Open Quarry and Concentrator Facility and Boric Acid Production Facility during their activities has been studied.
💡
Sonuç & Katkı:The removal efficiency of the MCDI process for arsenic was 94%.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Arsenic · Membrane capacitive deionization · Groundwater

Abstract

Access to water is a problem the magnitude of which increases day by day. In addition to water scarcity, water contamination also plays an important part in the exacerbation of this problem. Underground and surface waters can be polluted as a result of human activities as well as natural sources. One of the most commonly found natural pollutants is arsenic. Risks and effects of arsenic on health make it necessary to be treated from water. Conventional methods of arsenic removal make it necessary for new studies to be conducted because of problems such economical and special equipment needs. The MCDI process stands out with its advantages such as being economic, flexibly and installation a package process. In this study, using the optimum conditions which are operating times, flow rate, current, voltage, number of cycles, previously determined for Voltea brand MCDI, the removal of arsenic from the wastewater produced by Emet Bor Operation Directorate Espey Open Quarry and Concentrator Facility, Hisarcik Open Quarry and Concentrator Facility and Boric Acid Production Facility during their activities has been studied. The removal efficiency of the MCDI process for arsenic was 94%.

🔖

Bu Makaleye Atıf Yap

UZUN, H. İ., DEBİK, E. (2019). Detection of effective parameters in arsenic removal with capacitive deionization process and arsenic removal from wastewater. Environmental Research and Technology, Cilt: 2 Sayı: 1, 13–18. https://ajindex.com/articles/904912

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. S. Varol, A. Davraz and E. Varol, "Yeraltı suyu Kimyası ve Sağlığa Etkisinin Tıbbi Jeoloji Açısından Değerlendirilmesi", TAF Preventive Medicine Bulletin, Vol. 7, pp 351–356, 2008.
  2. Ü. Şahin, T.Tunç and S. Örs, "Utilization of Wastewater in Terms of Underground Water Pollution", Tarım Bilimleri Araştırma Dergisi, Vol. 4, pp. 33–39, 2011. U. Gebeloğlu, "Arsenic Removal with Electrochemical Wastewater Treatment Process", Gebze Institute of Technology, 2010. H.G. Gorchev and G. Ozolins, "WHO guidelines for drinking-water quality", 2011.
  3. R. Singh, S. Singh, P. Parihar, V.P. Singh and S.M. Prasad, "Arsenic contamination, consequences and remediation techniques: A review", Ecotoxicology and Environmental Safety, Vol. 112, pp. 247–270, 2015.
  4. A. Ortega, I. Oliva, K.E. Contreras, I. González, M.R. Cruz-Díaz and E.P. Rivero, "Arsenic removal from water by hybrid electro-regenerated anion exchange resin/electrodialysis process", Seperation and Purification Technology, Vol. 184, pp. 319–326, 2017.
  5. A.H. Smith, C. Hopenhayn-Rich, M.N. Bates, H.M. Goeden, I. Hertz-Picciotto, H.M. Duggan, R. Wood, M.J. Kosnett and M.T. Smith, "Cancer risks from arsenic in drinking water", Environmental Health Perspectives, Vol. 97, pp. 259–267, 1992. A. Guzmán, J.L. Nava, O. Coreño, I. Rodríguez and S. Gutiérrez, "Arsenic and fluoride removal from groundwater by electrocoagulation using a continuous filter-press reactor", Chemosphere, Vol. 144, pp. 2113–2120, 2016.
  6. B.F. Urbano, B.L. Rivas, F. Martinez and S.D. Alexandratos, "Water-insoluble polymer-clay nanocomposite ion exchange resin based on N-methyl-d-glucamine ligand groups for arsenic removal", Reactive and Functional Polymers, Vol. 72, pp. 642–649, 2012.
  7. A. Abejon, A. Garea and A. Irabien, "Arsenic removal from drinking water by reverse osmosis: Minimization of costs and energy consumption", Seperation and Purification Technology, Vol. 144, pp. 46–53, 2015.
  8. S.-Y. Huang, C.-S. Fan and C.-H. Hou, "Electro-enhanced removal of copper ions from aqueous solutions by capacitive deionization", Journal of Hazardous. Materials. Vol. 278, pp. 8–15, 2014.
  9. Y. Chen, L. Peng, Q. Zeng, Y. Yang, M. Lei, H. Song, L. Chai and J. Gu, "Removal of trace Cd(II) from water with the manganese oxides/ACF composite electrode", Clean Technologies and Environmental Policy, Vol. 17, pp. 49–57, 2014
  10. A.M. Silva, R.M.F. Lima and V.A. Leão, "Mine water treatment with limestone for sulfate removal", Journal of Hazardous Materials, Vol. 221–222, pp. 45–55, 2012. H. Li