Dergiler / Celal Bayar Üniversitesi Fen Bilimleri Dergisi / 2023 / Cilt: 19 - Sayı: 1

Determination of Optimal DC/AC Ratio for Grid-connected Photovoltaic Systems

Sayfa
19–29
Yayın Tarihi
2023-03-28
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Optimal values of ratios and efficiencies for Groups 1 and 2 are calculated as 1.28, 1.35, 91.55% and 90.62%, respectively.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Suitability evaluation of a location for solar power generation plant installation requires long-term measurements and calculations.
📊
Temel Bulgular & Veri:Energy production estimation values are calculated for different angles and DC/AC rated inverters.
💡
Sonuç & Katkı:Optimal values of ratios and efficiencies for Groups 1 and 2 are calculated as 1.28, 1.35, 91.55% and 90.62%, respectively.
🔬Tür:Laboratuvar & Saha Deneyi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Clipping · DC/AC ratio · Grid

Abstract

Suitability evaluation of a location for solar power generation plant installation requires long-term measurements and calculations. Since the energy production values and project power of solar power plant (SPP) directly affect the return period of the project cost. It is of considerable importance to make the calculations correctly. The effects of the DC/AC ratio, determining in an inverter selection, is a crucial parameter in determining the sizing of SPP. In this study, a model was used to find the closest estimation values. Irradiance values coming to SPP in Balıkesir/Turkey were simulated and DC energy at the inverter input was calculated. The results obtained from the calculation were compared with actual production values. To determine the optimum DC/AC ratio of the existing installed SPP system, calculations were made with two different methods. Energy production estimation values are calculated for different angles and DC/AC rated inverters. It is vital that the SPP consists of two groups with different directions and the same capacities in terms of comparing the accuracy of the calculation. Energy production calculations, including the hourly meteorological data and catalog values of the system, in the developed model are desired to provide the closest prediction values for energy production of the real system. The optimum DC/AC ratio also varies depending on the coordinates, direction and angle of the PV system. As a result, it has been observed that the direction and location of the PV system affect the selection of inverter power. Thus, it is important to calculate this ratio for efficient working conditions of each system. Optimal values of ratios and efficiencies for Groups 1 and 2 are calculated as 1.28, 1.35, 91.55% and 90.62%, respectively.

🔖

Bu Makaleye Atıf Yap

BEYOĞLU, M. F., DEMİRTAŞ, M. (2023). Determination of Optimal DC/AC Ratio for Grid-connected Photovoltaic Systems. Celal Bayar Üniversitesi Fen Bilimleri Dergisi, Cilt: 19 - Sayı: 1, 19–29. https://ajindex.com/articles/891703

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Referans1 Karafil, A., Ozbay, H., Kesler, M., & Parmaksiz, H., (2016), Calculation of optimum fixed tilt angle of PV panels depending on solar angles and comparison of the results with experimental study conducted in summer in Bilecik, Turkey. ELECO 2015, 971–976, https://doi.org/10.1109/ELECO.2015.7394517. Referans2 Rustemli, S. & Dincadam, F. & Demirtas, M. (2010). Performance comparison of the sun tracking system and fixed system in the application of heating and lighting. Arabian Journal for Science and Engineering. 35. 171-183. Referans3 Beyoğlu, M. F. (2011). Comparison of efficiencies of dual axis solar tracking system and fixed axis PV system in Balikesir City. Balıkesir University Institude of Science, Master thesis, https://hdl.handle.net/20.500.12462/2405. Referans4 Beyoğlu, M.F., Demirtaş, M. (2019). A comparative evalution of photovoltaic power plant energy production established in Balikesir province and production forecasting programs. International Marmara Sciences Congress (Autumn) 2019 Proceedings Book (Natural and Applied Sciences), (November), 401–406. Referans5 Abood, A., A. (2015). A comprehensive solar angles simulation and calculation using Matlab. International Journal of Energy and Enviroment, 6(4), 367–376, https://doi.org/10.1177/1098214005283748. Referans6 Jazayeri, K., Uysal, S., & Jazayeri, M. (2013). Matlab/Simulink based simulation of solar incidence angle and the sun’s position in the sky with respect to observation points on the Earth. Proceedings of 2013 International Conference on Renewable Energy Research and Applications, ICRERA 2013, 173–177, https://doi.org/10.1109/ICRERA.2013.6749746. Referans7 Demoulias, C. (2010). A new simple analytical method for calculating the optimum inverter size in grid-connected PV plants. Electric Power Systems Research, 80(10), 1197–1204, https://doi.org/10.1016/j.epsr.2010.04.005. Referans8 Wang, H. X., Muñoz-García, M. A., Moreda, G. P., & Alonso-García, M. C. (2018). Optimum inverter sizing of grid-connected photovoltaic systems based on energetic and economic considerations. Renewable Energy, 118, 709–717, https://doi.org/10.1016/j.renene.2017.11.063. Referans9 Faranda, R. S., Hafezi, H., Leva, S., Mussetta, M., & Ogliari, E. (2015). The optimum PV plant for a given solar DC/AC converter. Energies, 8(6), 4853–4870, https://doi.org/10.3390/en8064853. Referans10 Pandey, S., Kumar, R., & Panwar, K. (2019). Calculation of inverter power clipping loss due to PV array oversizing. Internat