Dergiler / PressAcademia Procedia / 2017 / Cilt: 5 - Sayı: 1

DETERMINATION OF ENHANCEMENT EFFECTS AT THE COMPTON TO COHERENT SCATTERING INTENSITIES X-RAYS USING FE-CU AND FE-ZN BINARY COMPOUNDS WITH WDXRF

Sayfa
431–433
Yayın Tarihi
2017-06-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Matrix enhancement effects have been examined with scattered X-rays by using WDXRF system for Fe-Cu and Fe-Zn binary compounds.
📊
Temel Bulgular & Veri:Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements.
💡
Sonuç & Katkı:Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Analyte · enhancement · compton scattering

Abstract

Matrix enhancement effects have been examined with scattered X-rays by using WDXRF system for Fe-Cu and Fe-Zn binary compounds. Fe as analyte and elements which some of them the K absorption edge just below the characteristic K X-ray energies of the analit (Fe) as matrix have been chosen. Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements. These samples have been analyzed in WDXRF system. At the end of measurement, the coherent and Compton scattering X-rays data of Rh Kα Xrays from these samples have been obtained. Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.

🔖

Bu Makaleye Atıf Yap

BOYDAS, E., YİLMAZ, D., BOYDAS, M. G. (2017). DETERMINATION OF ENHANCEMENT EFFECTS AT THE COMPTON TO COHERENT SCATTERING INTENSITIES X-RAYS USING FE-CU AND FE-ZN BINARY COMPOUNDS WITH WDXRF. PressAcademia Procedia, Cilt: 5 - Sayı: 1, 431–433. https://ajindex.com/articles/842663

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Han, I., Demir, L. 2009. “Mass attenuation coefficients, effective atomic and electron numbers of Ti and Ni alloys”,Radiation. Measurement, vol.44 no. 1,pp. 289-294.
  2. Speller, R. D., Horrocks, J. A. 1991,” Photon scattering--a "new' source of information in medicine and biology?” Physics in Medicine and Biology.Vol.36, no.,pp.1. Webster, D. J., Lillicrap, S. C.1985,”Coherent-Compton scattering for the assessment of bone mineral content using heavily filtered X-ray beams”,Physics in Medicine and Biology, volume 30, no. 6, pp. 531-539. Cooper,M.J., Rollason, A.J., Tuxworth, R.W. 1982,” Gamma-ray scattering studies of composition variations in alloys” J. Phys. E: Sci. Instrum,vol.15, pp. 568-572 Gigante,G.E.,. Pedraza, L.J, Sciuti, S. 1985,” Analysis of metal alloys by Rayleigh to Compton ratios and x-ray fluorescence peaks in the 50 to 122 keV energy range” Nucl. Inst. Meth, vol.12, pp. 229–234 Shakeshaft,J., Morgan H.M., Lillicrap, S.C.1997, “Gamma-ray scattering for fat fraction measurement”, Physics in Medicine and Biology, vol. 42, no.7,pp. 1403-1413.