Dergiler / Health Sciences Quarterly / 2020 / Cilt: 4 - Sayı: 4

DEVELOPMENT OF ELECTROCHEMICAL SENSORS FOR QUANTITATIVE ANALYSIS OF METHYLDOPA AT MODIFIED-GCE AND PGE ELECTRODES BY VOLTAMMETRY

Sayfa
223–236
Yayın Tarihi
2020-11-07
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The limit of quantification (LOQ) was calculated as 0.020 µM for modified-GCE and 0.040 µM for PGE.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Methyldopa is one of the important drugs used in the treatment of high blood pressure (hypertension).
📊
Temel Bulgular & Veri:Modified electrodes are important because they increase the sensitivity of the analysis.
💡
Sonuç & Katkı:The limit of quantification (LOQ) was calculated as 0.020 µM for modified-GCE and 0.040 µM for PGE.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:methyldopa · voltammetry · modified electrode

Abstract

Methyldopa is one of the important drugs used in the treatment of high blood pressure (hypertension). In addition to various methods such as chromatographic and spectrophotometric methods, electrochemical methods are used for the determination of methyldopa. However, poly (p-aminobenzene sulfonic acid), pen-tip graphite electrode (PGE) study was not found in the literature search. Modified electrodes are important because they increase the sensitivity of the analysis. Furthermore, electrochemical methods have advantages such as being faster and cheaper than other instrumental analysis methods, being more sensitive, not requiring long pretreatments in the preparation of samples. In this study, the glassy carbon electrode (GCE) was modified with poly(p-aminobenzene sulfonic acid) to prepare poly (p-aminobenzene sulfonic acid) -modified glassy carbon electrodes. Cyclic voltammetry (CV) technique was used for the electropolymerization process. Methyldopa was selected in various concentrations of phosphate pH 7.40 buffer, anodic and cathodic voltamograms were taken and oxidation and reduction properties were investigated. Measurements were taken at different scanning rates by CV technique and the current type of methyldopa was determined. Peak flow-concentration graphs were drawn from the measurements taken by Differential Pulse Voltammetry (DPV) technique and the linearity range was 0.020- 2.500 µM for modified-GCE and 0.020-2.820 µM for PGE. The limit of detection (LOD) was calculated as 0.006 µM for modified-GCE, 0.012 µM for PGE. The limit of quantification (LOQ) was calculated as 0.020 µM for modified-GCE and 0.040 µM for PGE.

🔖

Bu Makaleye Atıf Yap

YANIK, S., KURT, S. B., ARİ, B., DEMIRCI, S., YILMAZ, S. (2020). DEVELOPMENT OF ELECTROCHEMICAL SENSORS FOR QUANTITATIVE ANALYSIS OF METHYLDOPA AT MODIFIED-GCE AND PGE ELECTRODES BY VOLTAMMETRY. Health Sciences Quarterly, Cilt: 4 - Sayı: 4, 223–236. https://ajindex.com/articles/836588

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. AZARI, S., and ZOU, L. 2012, Using zwitter ionic amino acid l-DOPA tomodify the surface of thin film composite polyamide reverse osmosis membranes to increase their fouling resistance. J. Memb. Sci., 401–402, 68–75.
  2. BASTIDE, M.F., et al., 2015, Pathophysiology of L-dopa-induced motor and non-motor complications in Parkinson’sdisease. Prog. Neurobiol., 132, 96–168.
  3. BENZA K.R., GASH B., KLEBOVICH I, 1996, Determination of Methyldopa in Human Plasma by Validated HPLC with fluorescence detection, Journal of Chromatography, 730, 125-131.
  4. DE D, P., DI GIOVANNI, G., and Millan, M.J., 2017, Expanding the repertoire of L-DOPA’sactions: A comprehensive review of its functional neurochemistry. Prog. Neurobiol., 151, 57–100.
  5. DI GIOVANNI, G., CHAGRAOUI, A., PUGINIER, E., GALATI, S., and DE DEURWAERDÈRE, P., 2019, Reciprocal interaction between monoaminergic systems and the pedunculopontine nucleus: Implication in the mechanism of L-DOPA. Neurobiol. Dis., 128, 9–18.
  6. FOULADGAR, M., KARIMI, M.H., 2013, Ionic Liquid/Multiwall Carbon Nanotubes Paste Electrode for Square WaweVoltammetic Determination of Methyldopa, 19, 1163-70.
  7. GHOLIVAND M.B., AMIRI, M., 2009, Preparation of Polypyrrole/Nuclear Fast Red Films on Gold Electrode and Its Application on the Electrocatalytic Determination of Methyldopa and Ascorbic Acid, Electroanalysis, 21,22, 2461-67.
  8. HAUSER, R.A. 2009, Levodopa: Past, Present, and Future. Eur. Neurol., 62 (1), 1–8.
  9. HUANG F., JIN G., LIU Y., KONG J., 2008, Sensitive Determination of Phenylephrine and Chlorprothixene at Poly (4-aminobenzene sulfonic acid)-Modified Glassy Carbon Electrode, Talanta, 1435-41.
  10. JIN G., ZHANG Y., CHENG W., 2005, Poly (p-aminobenzene sulfonic acid)-Modified Glassy Carbon Electrode for Simultaneous of Dopamine and Ascorbic Acid, Sensors and Actuators B, 107, 52834. MERCURI, N., and BERNARDI, G. (2005) The ‘magic’ of -dopa: why is it the gold standard Parkinson’s disease therapy? Trends Pharmacol. Sci., 26 (7), 341–344.
  11. MO, J.W., OGOREVC, B., 2005, Simultaneous Measurement of Dopamine and Ascorbate at Their Physiological Levels Using Voltammetric Microprobe Based on Over oxidized Poly (1,2-Phenylenediamine)-Coated Carbon Fiber. Analytical Chemistry, 73, 1196-1202.
  12. MU, K., ZHANG, D., SHAO, Z., QıN, D., WANG, Y., WANG, S. 2017 Enhanced permeability and anti fouling performance of cellulose acetate ultra filtration membrane assisted by l-DOPA functionalized halloysite nanotubes. Carbohydr. Polym., 174, 688–696.
  13. MURRAY R.W., EWING A.G., DURS