Dergiler / Clinical and Experimental Ocular Trauma and Infection / 2019 / Cilt: 1 - Sayı: 2

Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair

Sayfa
104–108
Yayın Tarihi
2019-08-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Iatrogenic injuries of extra-ocular muscles should be considered if there is a restriction of eye movement after orbital fracture surgery.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: In this case report, we present a patient with lateral rectus muscle injury caused by excessive long screws inserted into the orbital rim by the plastic and reconstructive surgery department.
📊
Temel Bulgular & Veri:Case Presentation: A 60 year-old male patient presented with diplopia, esotropia and enopthalmus in his right eye fallowing orbital inferior wall fracture and tripod fracture surgery due to maxillofacial trauma.
💡
Sonuç & Katkı:Iatrogenic injuries of extra-ocular muscles should be considered if there is a restriction of eye movement after orbital fracture surgery.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:orbita · screw · diplopia

Abstract

Purpose: In this case report, we present a patient with lateral rectus muscle injury caused by excessive long screws inserted into the orbital rim by the plastic and reconstructive surgery department. Case Presentation: A 60 year-old male patient presented with diplopia, esotropia and enopthalmus in his right eye fallowing orbital inferior wall fracture and tripod fracture surgery due to maxillofacial trauma. In first examination limitation of right abduction was determined. Forced duction test showed that restriction in horizontal movements. Computed tomography showed the screws placed on the lateral wall were pushed into the orbit and pressed into the lateral rectus. After the removal of the screws, diplopia was improved but restriction of abduction still persistant. Conclusion: During the drilling and placement of the screws attention should be paid to the protection of structures. Iatrogenic injuries of extra-ocular muscles should be considered if there is a restriction of eye movement after orbital fracture surgery.

🔖

Bu Makaleye Atıf Yap

GÜLLÜLÜ, Z. Z., OLCAYSÜ, O. O., BUDAK, B. A., KIVANÇ, S. A. (2019). Injury Of The Orbit with Screws Secondary To Lateral Orbital Wall Repair. Clinical and Experimental Ocular Trauma and Infection, Cilt: 1 - Sayı: 2, 104–108. https://ajindex.com/articles/827417

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Alvi A, Doherty T, Lewen G. Facial fractures and concomitant injuries in trauma patients. Laryngoscope. 2003 Jan
  2. 113(1):102-6 2. Gabrielli MF, Monnazzi MS, Passeri LA, Carvalho WR, Gabrielli M, Hochuli-Vieira E. Orbital wall reconstruction with titanium mesh: retrospective study of 24 patients. Craniomaxillofac Trauma Reconstr. 2011 Sep
  3. 4(3):151-6 3. Turvey TA, Golden BA. Orbital anatomy for the surgeon. Oral Maxillofac Surg Clin North Am. 2012 Nov
  4. 24(4):525-36 4. Buchanan EP, Hopper RA, Suver DW, Hayes AG, Gruss JS, Birgfeld CB. Zygomaticomaxillary complex fractures and their association with naso-orbito-ethmoid fractures: a 5-year review. Plast Reconstr Surg. 2012 Dec
  5. 130(6):1296-304 5. Grob S, Yonkers M, Tao J. Orbital fracture Repair. Seminars in Plastic Surger. 2017 Feb
  6. 31(1): 31–9 6. Yaremchuk MJ, Del Vecchio DA, Fiala TG, Lee WP. Microfixation of acute orbital fractures. Ann Plast Surg. 1993 May
  7. 30(5):385-97 7. Gruss JS, Van Wyck L, Phillips JH, Antonyshyn O. The importance of the zygomatic arch in complex midfacial fracture repair and correction of posttraumatic orbitozygomatic deformities. Plast Reconstr Surg. 1990 Jun
  8. 85(6):878-90 8. Schreurs R, Dubois L, Becking AG, Maal TJJ. The orbit first! A novel surgical treatment protocol for secondary orbitozygomatic reconstruction. J Craniomaxillofac Surg. 2017 Jul
  9. 45(7):1043-50 9. Cho J, Ryu J. Alternative Treatment for Blow-In Fracture of Lateral Orbital Wall: Removal of the Fractured Fragment. J Craniofac Surg. 2016 Nov
  10. 27(8):2159-61 10. Hollier LH, Thornton J, Pazmino P, Stal S. The management of orbitozygomatic fractures. Plast Reconstr Surg. 2003
  11. 2386–92. 11. Mukherjee B, Priyadarshini O, Ramasubramanian S, Agarkar S. Iatrogenic Injury to Medial Rectus After Endoscopic Sinus Surgery. Indian Journal Otolaryngology Head Neck Surgery 2015 Dec
  12. 67(4):394-402 12. Peter Cikatricis P, Salvi SM, Burke JP. Iatrogenic Lateral Rectus Transection Secondary to Dental Implantation Surgery, Orbit, (2008) 27:4, 305-7 13. Del Moro G, Fabris S, Longatti P, Scarpa G. Watch the screw. An unusual complication of orbital reconstruction. J Oral Maxillofac Surg. 2014 Mar
  13. 72(3):645.e1-6 14. Lee HB, Nunery WR. Orbital adherence syndrome secondary to titanium implant material. Ophthalmic Plast Reconstr Surg. 2009 Jan-Feb
  14. 25(1):33-6 15. Shah HA, Shipchandler T, Vernon D, et al. Extra-ocular movement restriction and diplopia following orbital fracture repair. Am J Otolaryngol. 2018 Jan - Feb
  15. 39(1):34-6 16. Hwang CJ, Kat