Dergiler / Yekarum / 2014 / Cilt: 2 - Sayı: 2

The Investigation of Exergetic Performance of Cooling System With Geothermal Steam Ejector

Dergi
Yekarum
Sayfa
1–13
Yayın Tarihi
2014-11-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The 96 different cases are examined and the results are presented with graphics.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, application fields and potential of geothermal energy of Turkey are introduced.
📊
Temel Bulgular & Veri:Energetic performance of the system (COP) is obtained by the first law of thermodynamics and exergetic performance of the system (COPEX) is obtained by the second law of thermodynamics.
💡
Sonuç & Katkı:The 96 different cases are examined and the results are presented with graphics.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Geothermal energy · Steam ejector cooling · Energetic performance

Abstract

In this study, application fields and potential of geothermal energy of Turkey are introduced. Then, steam ejector cooling systems using geothermal heat source are presented and thermodynamics of the system is explained. Energetic performance of the system (COP) is obtained by the first law of thermodynamics and exergetic performance of the system (COPEX) is obtained by the second law of thermodynamics. In this present study, generator temperatures for ejector cooling system, which will be designed suitably for geothermal fields with low and middle temperatures of Turkey, are selected at interval of two different temperatures (low and middle temperatures). Generator temperatures (Tg) are 60-90C for applications with low temperatures, and 100-130C for applications with middle temperatures. The energetic performance (COP) and the exergetic performance (COPEX) of the system are evaluated for three different conditions of evaporator temperature (Te = 5, 10, 15 C) and two different conditions of condenser temperature (Tc = 30, 35 C). The intervals of temperature for evaluating the system performances are obtained from the experimental steam ejector cooling system designed. The 96 different cases are examined and the results are presented with graphics.

🔖

Bu Makaleye Atıf Yap

ÜÇGÜL, İ. (2014). The Investigation of Exergetic Performance of Cooling System With Geothermal Steam Ejector. Yekarum, Cilt: 2 - Sayı: 2, 1–13. https://ajindex.com/articles/822773

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. Hepbasli, A., “Development of geothermal energy utilization in Turkey: a review”, Renewable Reviews 8, 2004, 433-460. L., and Sustainable Energy Ozgener, L., Hepbasli, A., Dincer, I., “Energy and exergy analysis of geothermal district heating systems: an aapication”, Building and Environment 40, 2005, 1309-1322.
  2. Cerci, Y., “Performance evaluation of a single-flash geothermal power plant in Denizli, Turkey”, Energy 28, 2003, 27- Simsek, S., “Importance of geothermal energy in Turkey”, Int. Mediterranean Congress on Solar and Other New-Renewable Energy Resource, Antalya, Turkey,1998.
  3. Kaygusuz, K., “Geothermal energy in Turkey: the sustainable future”, Renewable and Sustainable Energy Rewiews 8, 2004, 545-5
  4. Kaygusuz A., Kanoglu, M., “Exergy analysis of a dual-level plant”, Geothermics 31, 2002, 709-724. geothermal power Sozen, A., “Performance improvement of absorption refrigeration system using triple-pressure- level”, Applied Thermal Engineering 23, 2003, 1577-593.
  5. Ozalp, M., Li, C.H., Wang, R.Z., Lu, Y.Z., “Investigation of a novel combined cycle of solar powered adsorption-ejection refrigeration system”, Renewable Energy 26, 2001, 611-622.
  6. Khattab N. M., Barakat M. H., “Modeling The Design and Performance Characteristic of Solar Steam- Jet Cooling for Comfort Air Conditioning”, Solar Energy, Vol.73, No.4, 2002, 257-267. A solar ejector cooling system using refrigerant R134 a in the Athens area”, Renewable Energy 30, 2005, 1457-1469.
  7. Huang, Petrenko, V.A., and Zhuk B., “A solar Chang, J.M., ejector cooling system using refrigerant R141b”, Solar Energy Vol. 64, Nos 4-6, 1998, 223-226.
  8. Kizilkan, O., “The investigation of applicability of steam-jet cooling system driven with conditioning”, Proceeding of Solar Energy Systems, 20-21 June, 2003, Mersin (in Turkish). air- jeothermal systems”, Journal of Thermal Science and Technology, Vol 12, No 1, 1989, pp. 31- 35 (in Turkish). ejector cooling “The investigation of jeothermal steam ejector cooling system irreversibilities”, Proceeding Conditioning, February 2005, Antalya (in Turkish). 67-71, 25-26-27 potential and its utilization in Turkey”, World Energy Council, Turc National Comittee, 6. Energy Congress of Turkiye, 17-22 October 1994, İzmir, pp. 69-82 (in Turkish). Ş., “Thermodynamic evaluation of Denizli Kızıldere geothermal power plant and its performance Conversion and Management 46, 2004, 245-2 Energy Kanoglu, “Economic evaluation of geothermal power generation, heating, and cooling”, Energy, Volume 24, Is