Dergiler / The International Journal of Energy and Engineering Sciences / 2017 / Cilt: 2 - Sayı: 2

COMPARISON OF AISC 360 – 16 AND EC4 FOR THE PREDICTION OF COMPOSITE COLUMN CAPACITY

Sayfa
3–22
Yayın Tarihi
2017-04-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The important parameters in calculations will also be specified to underline the best way in the design field

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Composite constructions are used widely in civil engineering structures.
📊
Temel Bulgular & Veri:Composite columns are a significant application of composite construction, and the ConcreteFilled Steel Tube (CFST) columns are the most common type of composite columns.
💡
Sonuç & Katkı:The important parameters in calculations will also be specified to underline the best way in the design field
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Composite columns · CFST column · Axial capacity

Abstract

Composite constructions are used widely in civil engineering structures. The steel and concrete act together to resist the loads. Composite columns are a significant application of composite construction, and the ConcreteFilled Steel Tube (CFST) columns are the most common type of composite columns. The CFST columns have been increasingly used all over the world due to their inherent advantages, and in particular because of their favorable behavior under seismic loads. The steel tube effectively confines the concrete core, providing a highly ductile response under compression and a high energy absorption capacity. This type of composite column has been used primarily in bridges, reservoirs, and tall buildings. Circular CFST column provides much more effective confinement to the core concrete than other types of column sections under axial load due to an enhancement of composite action between steel tube and core concrete. Many design specifications used to predict the capacity of CFST columns, the ANSI/AISC 360 – 16 and the Eurocode 4 (EC4). The ANSI/AISC 360 – 16 is the specification for steel structures in the United States; the Eurocode 4 is the European code for composite structure design, respectively. The objective of this study is to investigate the differences between the AISC 360-16 and the EC4 approaches of circular CFST columns under axial load and to evaluate how well they model the actual column behavior through a series of statistical comparisons. Also, the parameters which are used in design specification calculations steps will be assessed. The important parameters in calculations will also be specified to underline the best way in the design field

🔖

Bu Makaleye Atıf Yap

AL-ELİWİ, B. J., EKMEKYAPAR, T., AL-JUBOORİ, H. A. (2017). COMPARISON OF AISC 360 – 16 AND EC4 FOR THE PREDICTION OF COMPOSITE COLUMN CAPACITY. The International Journal of Energy and Engineering Sciences, Cilt: 2 - Sayı: 2, 3–22. https://ajindex.com/articles/806000

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Abed, F., AlHamaydeh, M., and Abdalla, S. (2013). Experimental and numerical investigations of the compressive behavior of concrete filled steel tubes (CFSTs). Journal of Constructional Steel Research, 80, 429-439. doi: 10.1016/j.jcsr.2012.10.005 AISC360-16. (2016). ANSI/AISC 360-16 Specification for Structural Steel Buildings (pp. 676). Chicago, Illinois, USA: American institute of steel construction. An, Y.-F., Han, L.-H., and Zhao, X.-L. (2012). Behaviour and design calculations on very slender thin-walled CFST columns. Thin-Walled Structures, 53, 161-175. doi: 10.1016/j.tws.2012.01.011 Aslani, F., Uy, B., Tao, Z., and Mashiri, F. (2015). Predicting the axial load capacity of high-strength concrete filled steel tubular columns. Steel and Composite Structures, 19(4), 967-993. doi: 10.12989/scs.2015.19.4.967 de Oliveira, W. L. A., De Nardin, S., de Cresce El Debs, A. L. H., and El Debs, M. K. (2009). Influence of concrete strength and length/diameter on the axial capacity of CFT columns. Journal of Constructional Steel Research, 65(12), 2103-2110. doi: 10.1016/j.jcsr.2009.07.004 EC4. (2004). EN1994-1-1Eurocode4. DesignofCompositeSteelandConcreteStructures-Part 1-1:General Rules and Rules for Buildings (pp. 117). CEN, Brussels: European Committee for Standardization. Ekmekyapar, T., and Al-Eliwi, B. J. M. (2016). Experimental behaviour of circular concrete filled steel tube columns and design specifications. Thin-Walled Structures, 105, 220-230. doi: 10.1016/j.tws.2016.04.004 Giakoumelis, G., and Lam, D. (2004). Axial capacity of circular concrete-filled tube columns. Journal of Constructional Steel Research, 60(7), 1049-1068. doi: 10.1016/j.jcsr.2003.10.001 Han, L.-H., Li, W., and Bjorhovde, R. (2014). Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members. Journal of Constructional Steel Research, 100, 211-228. doi: 10.1016/j.jcsr.2014.04.016 Han, L.-H., Yao, G.-H., and Zhao, X.-L. (2005). Tests and calculations for hollow structural steel (HSS) stub columns filled with self-consolidating concrete (SCC). Journal of Constructional Steel Research, 61(9), 1241-1269. doi: 10.1016/j.jcsr.2005.01.004 Johansson, M. (2002). The efficiency of passive confinement in CFT columns. Steel and Composite Structures, 2(5), 379-396. doi: 10.12989/scs.2002.2.5.379 Le Hoang, A., and Fehling, E. (2017). Numerical study of circular steel tube confined concrete (STCC) stub columns. Journal of Constructional Steel Research, 136, 238-2