⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusions: In these experimental study conditions, it was concluded that the presence of calcium hydroxide in simulated immature teeth and file size affect the EAL.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: The aim of this research was to appreciate the effects of different file sizes and the presence of calcium hydroxide on the correctness of the electronic apex locator (EAL) at simulated immature teeth.
📊
Temel Bulgular & Veri:Methods: In this study, 30 maxillary central teeth were used beforehand extracted due to periodontal reasons.
💡
Sonuç & Katkı:Conclusions: In these experimental study conditions, it was concluded that the presence of calcium hydroxide in simulated immature teeth and file size affect the EAL.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Apex Locater · Root Canal · Calcium Hydroxide

Abstract

Objective: The aim of this research was to appreciate the effects of different file sizes and the presence of calcium hydroxide on the correctness of the electronic apex locator (EAL) at simulated immature teeth. Methods: In this study, 30 maxillary central teeth were used beforehand extracted due to periodontal reasons. The actual root canal length determined with K-File and measured behind 0.5mm from the apex. In order to simulate an immature tooth, the apical of roots were prepared with a diameter of 1,4mm Gates-Glidden drills and K-Files. Working lengths of samples were measured using the Root ZX by 110-140 K-Files. Each measurement was repeated three times and averaged. Then all the samples were filled with calcium hydroxide medicament and working lengths were determined by the same method. Statistical analysis was performed using the Two-way ANOVA. Results: The measurements were closer to the actual root canal length as the diameter of the file increased at the presence and absence of calcium hydroxide. However, there was a difference between the presence and absence of calcium hydroxide in the determination of root canal length. Conclusions: In these experimental study conditions, it was concluded that the presence of calcium hydroxide in simulated immature teeth and file size affect the EAL.

🔖

Bu Makaleye Atıf Yap

AYRANCİ, L., ÇETİNKAYA, A., ÖZKAN, S. (2019). The Effect of Calcium Hydroxide and File Sızes on the Accuracy of the Electronic Apex Locator in Simulated Immature Teeth. Middle Black Sea Journal of Health Science, Cilt: 5 - Sayı: 3, 273–278. https://ajindex.com/articles/791173

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Angwaravong O, Panitvisai P (2009). Accuracy of an electronic apex locator in primary teeth with root resorption. Int Endod J 42(2):115-21.
  2. Athanassiadis B, Abbott PV, Walsh LJ (2007). The use of calcium hydroxide, antibiotics and biocides as antimicrobial medicaments in endodontics. Aust Dent J 52(1):64-82.
  3. Baldi JV, Victorino FR, Bernardes RA, de Moraes IG, Bramante CM, Garcia RB et al. (2007). Influence of embedding media on the assessment of electronic apex locators. J Endod 33(4):476-79.
  4. Bystrom A, Claesson R, Sundqvist G (1985). The antibacterial effect of camphorated paramonochlorophenol, camphorated phenol and calcium hydroxide in the treatment of infected root canals. Endod Dent Traumatol 1(5):170-75.
  5. Dunlap CA, Remeikis NA, BeGole EA, Rauschenberger CR (1998). An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endodont 24(1):48-50.
  6. Ebrahim AK, Yoshioka T, Kobayashi C, Suda H (2006). The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study. Aust Dent J 51(2):153-57.
  7. Freeman BA, Crapo JD (1982). Free-Radicals and Tissue-Injury. Lab Invest 47(5):412-26.
  8. Gordon MP, Chandler NP (2004). Electronic apex locators. Int Endod J 37(7):425-37.
  9. Herrera M, Abalos C, Lucena C, Jimenez-Planas A, Llamas R (2011). Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study. J Endod 37(9):1306-9.
  10. Hulsmann M, Pieper K (1989). Use of an electronic apex locator in the treatment of teeth with incomplete root formation. Endod Dent Traumatol 5(5):238-41.
  11. JI Ingle, LK Bakland, DL Peters, LS Buchanan, TP Mullaney. Endodontic Cavity Preparation. In:Ingle JI, Bakland LK (Editors). Endodontics, 4th ed. Baltimore: Williams & Wilkins. 1994:220–24.
  12. Jeger FB, Janner SFM, Bornstein MM, Lussi A (2012). Endodontic Working Length Measurement with Preexisting Cone-Beam Computed Tomography Scanning: A Prospective, Controlled Clinical Study. J Endodont 38(7):884-88.
  13. Jenkins JA, Walker WA, 3rd, Schindler WG, Flores CM (2001). An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants. J Endod 27(3):209-11.
  14. Kolanu SK, Bolla N, Varri S, Thummu J, Vemuri S, Mandava P (2014). Evaluation of Correlation Between apical Diameter and File Size Using Propex Pixi Apex Locator. J Clin Diagn Res 8(12):ZC18-20. Lambrianidis T, Margelos J, Beltes P (1999). Removal efficiency of calcium hyd