Dergiler / Journal of Health Sciences and Medicine / 2022 / Cilt: 5 - Sayı: 1

Tp-e interval and Tp-e/JT ratio before and after catheter ablation in patients with Wolff Parkinson White syndrome

Sayfa
291–296
Yayın Tarihi
2022-01-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: This study demonstrated that Tp-e and Tp-e/JT were significantly diminished in WPW after the ablation.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: Tp-e and Tp-e/QT are novel markers of ventricular repolarization.
📊
Temel Bulgular & Veri:However, preexcitation in Wolff Parkinson White (WPW) syndrome may preclude accurate measurement of repolarization as assessed by the QT.
💡
Sonuç & Katkı:Conclusion: This study demonstrated that Tp-e and Tp-e/JT were significantly diminished in WPW after the ablation.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Catheter ablation · JT interval · Tp-e interval

Abstract

Aim: Tp-e and Tp-e/QT are novel markers of ventricular repolarization. However, preexcitation in Wolff Parkinson White (WPW) syndrome may preclude accurate measurement of repolarization as assessed by the QT. We aimed to research the assessment of Tp-e and Tp-e/JT before and after ablation in WPW. Material and Method: We enrolled 50 consecutive patients with symptomatic WPW syndrome who underwent catheter ablation of their accessory pathways for treatment. All of the patients were successfully ablated. ECGs were performed before the procedure and repeated after the ablation procedure. Results: Tp-e (86.6±16.2 vs 80.6±12.5; p=0.021) and Tp-e(c) (96.7±18.9 vs 88.3±11.2; p=0,005) showed a significant decrease after the procedure. Tp-e/JT (0.307±0.053 vs 0.279±0.040; p=0.001) and Tp-e/JT(c) (0.276±0.048 vs 0.255±0.045; p=0.009) showed a significant decrease after the procedure. There was a significant association between ERP and before procedure Tp-e (c) (r=- 0.370, p=0.008) and Tp-e/JT (r=- 0.371, p=0.008). Conclusion: This study demonstrated that Tp-e and Tp-e/JT were significantly diminished in WPW after the ablation.

🔖

Bu Makaleye Atıf Yap

AKDİ, A., ÖZEKE, Ö. (2022). Tp-e interval and Tp-e/JT ratio before and after catheter ablation in patients with Wolff Parkinson White syndrome. Journal of Health Sciences and Medicine, Cilt: 5 - Sayı: 1, 291–296. https://ajindex.com/articles/774612

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Bhatia A, Sra J, Akhtar M. Preexcitation syndromes. Curr Probl Cardiol 2016; 41: 99-137.
  2. Cho JH, Leong D, Cuk N, et al. Delayed repolarization and ventricular tachycardia in patients with heart failure and preserved ejection fraction. PloS One 2021; 16: e0254641. Kors JA, van Eck HJR, van Herpen G. The meaning of the Tp-Te interval and its diagnostic value. J Electrocardiol 2008; 41: 575-80.
  3. Antzelevitch C, Sicouri S, Di Diego JM, et al. Does Tpeak-Tend provide an index of transmural dispersion of repolarization? Heart Rhythm 2007; 4: 1114-6.
  4. Karaman K, Altunkaş F, Çetin M, et al. New markers for ventricular repolarization in coronary slow flow: Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio. Ann Noninvasive Electrocardiol 2015; 20: 338-44.
  5. Castro Hevia J, Antzelevitch C, Tornés Bárzaga F, et al. Tpeak-Tend and Tpeak-Tend dispersion as risk factors for ventricular tachycardia/ventricular fibrillation in patients with the Brugada syndrome. J Am Coll Cardiol 2006; 47: 1828-34.
  6. Smetana P, Schmidt A, Zabel M, et al. Assessment of repolarization heterogeneity for prediction of mortality in cardiovascular disease: peak to the end of the T wave interval and nondipolar repolarization components. J Electrocardiol 2011; 44: 301-8.
  7. Zhao X, Xie Z, Chu Y, et al. Association between Tp-e/QT ratio and prognosis in patients undergoing primary percutaneous coronary intervention for ST-segment elevation myocardial infarction. Clin Cardiol 2012; 35: 559-64.
  8. Gupta P, Patel C, Patel H, et al. Tp-e/QT ratio as an index of arrhythmogenesis. J Electrocardiol 2008; 41: 567-74.
  9. Zhou SH, Wong S, Rautaharju PM, Karnik N, Calhoun HP. Should the JT rather than the QT interval be used to detect prolongation of ventricular repolarization? J Electrocardiol 1992; 25: 131-6.
  10. Ceresnak SR, Dubin AM, Kim JJ, et al. Success rates in pediatric WPW ablation are improved with 3-dimensional mapping systems compared with fluoroscopy alone: A multicenter study. J Cardiovasc Electrophysiol 2015; 26: 412-6.
  11. Salim MA, Case CL, Gillette PC. The JT interval as a depolarization independent measurement of repolarization: lessons from catheter ablation of the Wolff-Parkinson-White syndrome. Pacing Clin Electrophysiol 1995; 18: 2158-62.
  12. Tabatabaei P, Keikhavani A, Haghjoo M, et al. Assessment of QT and JT Intervals in Patients With Left Bundle Branch Block. Res Cardiovasc Med 2016; 5: e31528. Kors JA, van Eck HJR, van Herpen G. The meaning of the Tp-Te interval and its diagnostic value. J Electrocardiol 200