Dergiler / Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi / 2009 / Cilt: 22 - Sayı: 1

Pounding Of Adjacent RC Buildings During Seismıc Loads

Sayfa
129–145
Yayın Tarihi
2009-06-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It is concluded that pounding forces are not completely absorbable because of their high values but their effects on structure can be reduced by placing elastic materials between adjacent buildings or by reinforcing structural systems with cast-in-place reinforced concrete (RC) walls.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Turkey is in high seismic risk zone.
📊
Temel Bulgular & Veri:On a possible earthquake, adjacent buildings which are not separated from each other properly are under pounding risk.
💡
Sonuç & Katkı:It is concluded that pounding forces are not completely absorbable because of their high values but their effects on structure can be reduced by placing elastic materials between adjacent buildings or by reinforcing structural systems with cast-in-place reinforced concrete (RC) walls.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Adjacent building · pounding (impact) · seismic load

Özet

Turkey is in high seismic risk zone. On a possible earthquake, adjacent buildings which are not separated from each other properly are under pounding risk. Although gap size requirements are given in Turkish Earthquake Code (TEC), in Turkey, adjacent buildings are still been constructing with insufficient gap sizes. In this paper; results of pounding and effects of pounding to structural elements of buildings are studied. Stress analyses are made on frame models for different impact points and analysis results are discussed. It is concluded that pounding forces are not completely absorbable because of their high values but their effects on structure can be reduced by placing elastic materials between adjacent buildings or by reinforcing structural systems with cast-in-place reinforced concrete (RC) walls.

Abstract

Turkey is in high seismic risk zone. On a possible earthquake, adjacent buildings which are not separated from each other properly are under pounding risk. Although gap size requirements are given in Turkish Earthquake Code (TEC), in Turkey, adjacent buildings are still been constructing with insufficient gap sizes. In this paper; results of pounding and effects of pounding to structural elements of buildings are studied. Stress analyses are made on frame models for different impact points and analysis results are discussed. It is concluded that pounding forces are not completely absorbable because of their high values but their effects on structure can be reduced by placing elastic materials between adjacent buildings or by reinforcing structural systems with cast-in-place reinforced concrete (RC) walls.

🔖

Bu Makaleye Atıf Yap

DOĞAN, M., GÜNAYDIN, A. (2009). Pounding Of Adjacent RC Buildings During Seismıc Loads. Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi, Cilt: 22 - Sayı: 1, 129–145. https://ajindex.com/articles/755171

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. S. Muthukumar and R. DesRoches, “A Hertz contact model with non-linear damping for simulation”, Earthquake Eng. and Structural Dynamics, Vol. 35, pp. 811-828, 2006
  2. S.E. AbdelRaheem, “Seismic pounding between adjacent building structures”, Electronic Journal of Structural Engineering, Vo. 6, pp. 66-74, 2006
  3. B.D.Westermo, “The Dynamics of interstructural connection to prevent pounding”, Earthquake Engineering and Structural Dynamics, Vol. 18, pp. 687-699, 1989
  4. B.F. Maison and K.Kasai, “Analysis for type of structural pounding”, Journal of Structural Engineering, Vol. 116(4), pp. 957-975, 1990
  5. S.A. Anagnostopoulos, “Pounding of buildings in series during earthquakes”, Earthquake Engineering and Structural Dynamics, Vol.16, pp. 443-456, 1988
  6. S.A. Anagnostopoulos, “An Investigation of earthquake induced pounding between adjacent buildings”, Earthquake Eng.and Structural Dynamics, Vol. 21, pp. 289-302, 1992
  7. D.L. Garcia, “Discussion on: Critical building separation in reducing pounding risk under earthquake excitation”, Structural Safety, Vol. 27, pp. 393-396, 2005
  8. V.A. Matsagar and R.S. Jangid, “Viscoelastic damper connected to adjacent structures involving seismic isolation”, Journal of Civil Engineering and Management, Vol. 11(4), pp. 309-322,2005
  9. The Ministry of Public Works and Settlement, Turkish Earthquake Code, 2007
  10. C.E.N. Eurocode 8: Design of Structures for Earthquake Resistance, European Committee for Standardization, 1998
  11. C.S.I. SAP2000 Advanced v10.0.7 (Structural Analysis Program), Computers and Structures Inc., 2007.