Dergiler / Environmental Research and Technology / 2020 / Cilt: 3 - Sayı: 4

Evaluation of electrochemical treatment of real hospital wastewater with different electrode materials

Sayfa
175–181
Yayın Tarihi
2020-12-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

When all parameters are evaluated, optimum electro kinetic conditions for treatment of HWW was obtained for 10V 5 min by the Fe electrode.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this paper, the treatment of real hospital wastewater (HWW) by electrocoagulation process (EC), which is one of the electrochemical treatment methods, has been evaluated.
📊
Temel Bulgular & Veri:Experimental studies were conducted at 5, 10, 20, 30 voltage (V) and 5, 10, 20, 30, 45 minutes (min) exposure times. pH, temperature, and conductivity were monitored.
💡
Sonuç & Katkı:When all parameters are evaluated, optimum electro kinetic conditions for treatment of HWW was obtained for 10V 5 min by the Fe electrode.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Hospital wastewater · electrocoagulation · aluminum electrode

Abstract

In this paper, the treatment of real hospital wastewater (HWW) by electrocoagulation process (EC), which is one of the electrochemical treatment methods, has been evaluated. In the EC process, aluminum (Al) and iron (Fe) plates as anode and cathode are used. Experimental studies were conducted at 5, 10, 20, 30 voltage (V) and 5, 10, 20, 30, 45 minutes (min) exposure times. pH, temperature, and conductivity were monitored. COD and phenol removal were evaluated. As a result of experimental studies, Al and Fe electrodes were effective in the treatment of HWW with EC. The highest COD removal efficiency was 93% at 30V 10 min and 95% at 30V 5 min for Al and Fe electrode, respectively. The highest phenol removal efficiency is 97% at 10V 10 min and 97% at 10V 5 min for Al and Fe electrode. When all parameters are evaluated, optimum electro kinetic conditions for treatment of HWW was obtained for 10V 5 min by the Fe electrode.

🔖

Bu Makaleye Atıf Yap

AKKAYA, G. K. (2020). Evaluation of electrochemical treatment of real hospital wastewater with different electrode materials. Environmental Research and Technology, Cilt: 3 - Sayı: 4, 175–181. https://ajindex.com/articles/754246

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. . S. Top, 2016. Characterization of hospital wastewater and inverstigation of treatment alternatives, Fen Bilimleri Enstitüsü, YTÜ, İstanbul, Turkey. [2]. A. R. Mesdaghinia, K. Naddafi, R. Nabizadeh R. Saeedi M. Zamanzadeh, “Wastewater characteristics and appropriate methods for wastewater management in the hospitals”, Iran J Public Health, 38:34–40, 2009. [3]. H. A. Abd El-Gawad, A. M. Aly, A”ssessment of aquatic environmental for wastewater management quality in the hospitals: a case study”, Aust J Basic Appl Sci, 5(7):474–482, 2011. [4]. C. Boillot, C. Bazin, F. Tissot-Guerraz, J. Droguet, M. Perraud, J. C. Cetre et al., “Daily physicochemical, microbiological and ecotoxicological fluctuations of a hospital effluent according to technical and care activities”, Sci Total Environ, 403:113–129, 2008. [5]. H. A. Duong, N. H. Pham, H. T. Nguyen, T. T. Hoang, H. V. Pham, V. C. Pham, M. Berg, W. Giger, A. C. Alder, “Occurrence, fate and antibiotic resistance of fluoroquinolone antibacterials in hospital wastewaters in Hanoi, Vietnam”, Chemosphere, 72:968–973, 2008. [6]. P. Verlicchi, M. Al Aukidy, A. Galletti, M. Petrovic, D. Barcelo´, “Hospital effluent: investigation of the concentrations and distribution of pharmaceuticals and environmental risk assessment”, Sci Total Environ, 430:109–118, 2012. [7]. S. Yuan, X. Jiang, X. Xia, H. Zhang, S. Zheng, “Detection, occurrence and fate of psychiatric pharmaceuticals in psychiatric hospital and municipal wastewater treatment plants in Beijing, China”, Chemosphere, 90:2520–252, 2013. [8]. V. P. Prabhasankar, D. I. Joshua, K. Balakrishna, I. F. Siddiqui, S. Taniyasu, N.Yamashita, K. Kannan, M. Akiba, Y. Praveenkumarreddy, K. S. Guruge, “Removal rates of antibiotics in four sewage treatment plants in South India”, Environ Sci Pollut Res., doi:10.1007/s11356- 015-5968-3, 2016. [9]. M. Al Aukidy, S. Al Chalabi, P. Verlicchi, “Hospital wastewater treatments adopted in Asia, Africa, and Australia. In Hospital Wastewaters”, Springer, Cham., pp. 171-188, 2017. [10]. Ü. T. Ün, S. Uğur, A. S. Koparal, Ü. B. Öğütveren, “Electrocoagulation of olive mill wastewaters”, Separation and Purification Technology, 52(1), 136-141, 2006. [11]. N. Adhoum, L. Monser, “Decolourization and removal of phenolic compounds from olive mill wastewater by electrocoagulation,” Chemical Engineering and Processing: Process Intensification, 43(10), 1281-1287, 2004 [12]. M. Y. A. Mollah, R. Schennach, J. R. Parga, D. L. Cocke, “Electrocoagulation (EC)