Dergiler / Environmental Research and Technology / 2022 / Cilt: 5 - Sayı: 2

Assessing the efficiency of drinking water treatment plant and the impact of broken distribution systems on water quality of Wukari-Ibi plant

Sayfa
155–164
Yayın Tarihi
2022-06-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

There is also a need for government to invest in infrastructure and equipment so as to upgrade the treatment plant.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Water treatment is essential in the provision of potable drinking water to communities.
📊
Temel Bulgular & Veri:The results indicated that after treatment, turbidity (6.74 NTU) and coliform count (17 cfu/100 mL) were still significantly greater than standard guidelines, which suggest that the treatment plant is unable to reduce the concentration of these contaminants to a safe level for consumption.
💡
Sonuç & Katkı:There is also a need for government to invest in infrastructure and equipment so as to upgrade the treatment plant.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Contaminants · efficiency · water quality

Abstract

Water treatment is essential in the provision of potable drinking water to communities. However, studies have shown that many local conventional drinking water treatment plants in Nigeria are ineffective in removing contaminants. This study evaluated the efficiency of drinking water from Wukari-Ibi plant by assessing water samples before and after treatment and comparing results to national and international drinking water standards. Forty water samples were collected and selected physical and biological parameters were determined according to standard laboratory procedures. The results indicated that after treatment, turbidity (6.74 NTU) and coliform count (17 cfu/100 mL) were still significantly greater than standard guidelines, which suggest that the treatment plant is unable to reduce the concentration of these contaminants to a safe level for consumption. Furthermore, assessing water at consumer taps indicated that broken distribution system is likely serving as a potential pathway for contamination. The plant removal efficiency of colour, turbidity, Total Dissolved Solids, hardness, and coliform count was computed as 74.7%, 66.57%, 32.58%, 30.11%, and 59.88% respectively. Overall, the removal efficiency was 52.77% which is considered unacceptable for the supply of potable drinking water. The study concludes that cost and poor skilled personnel are the major factors in the inefficient treatment and therefore we suggest a low-cost treatment using activated carbon from locally sourced plants to be incorporated for effective removal of contaminants. There is also a need for government to invest in infrastructure and equipment so as to upgrade the treatment plant.

🔖

Bu Makaleye Atıf Yap

EZEKİEL, S., JOSHUA, W., WİLLİAMS, A. G. (2022). Assessing the efficiency of drinking water treatment plant and the impact of broken distribution systems on water quality of Wukari-Ibi plant. Environmental Research and Technology, Cilt: 5 - Sayı: 2, 155–164. https://ajindex.com/articles/754179

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. . R. Kumar, V. Sharma, R.C. and Sharma “Physico-chemical and Microbiological water quality of Asian wetland of Garhwal Himalaya, India”. International Journal of Ecological Science and Environmental Engineering, Vol. 5(3), pp. 64-70, 2018. [2]. W.K Joshua. Groundwater quality assessment: a case study of groundwater from hand-dug wells in Hawul Local Government Area of Borno State”. International Journal of Advance Research, Vol. 3(2), pp. 537-546, 2015. [3]. A.Q. Ibrahim, P.C. Onyenekwe, and I.M. Nwaedozie. “An Efficiency Assessment of Lower Usuma Water Treatment Plant in Abuja Metropolis, Nigeria”, Journal of Environmental Science, Vol. 8(12), pp. 46-53, 2014. [4]. A.G. Olufemi, O. Ogheneochuko Utieyin, and O.M. Adebayo. “Assessment of Groundwater Quality and Saline Intrusions in Coastal Aquifers of Lagos Metropolis, Nigeria”, Journal of Water Resource and Protection, Vol. 2(10), pp. 849-853, 2010. [5]. World Health Organization (2006). “Guidelines for Drinking Water Quality”, 3rd edition, Geneva: Switzerland., 2006. [6]. L.P. Chegbeleh, D.K. Aklika, and B.A. Akurugu. “Hydrochemical Characterization and Suitability Assessment of Groundwater Quality in the Saboba and Chereponi Districts, Ghana”, Hydrology, Vol. 7(3), pp. 53-60, 2020. [7]. A. Shea, J. Poon, and S. Williamson. “Microbial risk assessment of drinking water to set health-based performance targets to improve water quality and treatment plant operations”. Water Practice and Technology, Vol. 11(2), pp. 495-502, 2016. [8]. A.S. Al Chalabi. “Assessment of Drinking Water Quality and the Efficiency of the Al-Buradieiah Water Treatment Plant in Basra City”. Nature Environment and Pollution Technology, Vol. 19(3), pp. 1057-1065, 2020. [9]. W.K. Joshua. “Assessing Rural Water Quality: comparing improved and unimproved drinking water sources in Hawul LGA”. SNRU Journal of Science and Technology, Vol. 13(2), pp. 55-62, 2021. [10]. M. Mustapha, M. Sridhar, and A.O. Coker. “Assessment of water supply system from catchment to consumers as framed in East Nigeria”. Sustainable Environment, Vol. 7(1), pp. 1-14, 2021. [11]. M. Mustapha, M. Sridhar, A.O. Coker, A. Ajayi, and A. Suleiman. “ Risk Assessment from catchment to consumers as framed in water safety plans: A study from Maiduguri water treatment plant, Northeast Nigeria”. Journal of Environmental Protection, Vol. 10(10), pp. 1373-1390, 2019. [12]. A. Alver. “ Evaluation of conventional drinking water treatment plant efficiency according to water quality