In the parameter analysis, two different evaporator temperatures (-150 and 150C) and condenser temperature (350C) were accepted.
📌 3 Maddede Bu Makale
🎯
Amaç & Hipotez:Refrigerants used in the cooling industry and released into the atmosphere cause global environmental problems.
📊
Temel Bulgular & Veri:In this study, the energy parameters of R450A and R134a refrigerant fluids, consisting of a mixture of R134a / R1234ze (E) with low GWP ratio that can be used as an alternative to R134a, were analyzed theoretically and environmentally for a small capacity vapor compression cooling system.
💡
Sonuç & Katkı:In the parameter analysis, two different evaporator temperatures (-150 and 150C) and condenser temperature (350C) were accepted.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:New generation refrigerants · R450A · global warming
Özet
Refrigerants used in the cooling industry and released into the atmosphere cause global environmental problems. In the field of cooling and air conditioning, the use of chlorofluorocarbon and hydrochlorofluorocarbon is the main cause of thinning of the ozone layer and global warming. Replacing hydrofluorocarbons used as refrigerants with lower global warming potential (GWP) refrigerants is among the priority issues in preventing environmental problems. In this study, the energy parameters of R450A and R134a refrigerant fluids, consisting of a mixture of R134a / R1234ze (E) with low GWP ratio that can be used as an alternative to R134a, were analyzed theoretically and environmentally for a small capacity vapor compression cooling system. In the parameter analysis, two different evaporator temperatures (-150 and 150C) and condenser temperature (350C) were accepted.
KUMAŞ, K., AKYÜZ, A. Ö. (2020). Performance Analysis of R450A Refrigerant in Vapor Compression Cooling System for Sustainable Environment. Akademia Doğa ve İnsan Bilimleri Dergisi, Cilt: 6 - Sayı: 1, 57–71. https://ajindex.com/articles/730196
Belman-Flores, J. M., Rodríguez-Muñoz, A. P., Pérez-Reguera, C. G., Mota-Babiloni, A. (2017). Experimental study of R1234yf as a drop-in replacement for R134a in a domestic refrigerator. International Journal of Refrigeration, 81, 1-11. https://doi.org/10.1016/j.ijrefrig.2017.05.003
Bolaji, B. O., Adeleke, A. E., Adu, M. R.(2019).
Olanipekun, M. U. Akinnibosun, E.: Theoretical Investigation of Energy-Saving Potential of Eco-Friendly R430A, R440A and R450A Refrigerants in a Domestic Refrigerator. Iranian Journal of Science and Technology, Transactions of Mechanical Engineering,43,103–112. https://doi.org/10.1007/s40997-017-0110-4
Caliskan, H. (2017). Energy, exergy, environmental, enviroeconomic, exergoenvironmental (EXEN) and exergoenviroeconomic (EXENEC) analyses of solar collectors. Renewable and Sustainable Energy Reviews, 69,488–492. https://doi.org/10.1016/j.rser.2016.11.203.
Devecioğlu A.G., Oruç V. (2018). A Comparative Energetic Analysis for Some Low-Gwp Refrigerants as R134a Replacements in Various Vapor Compression Refrigeratıon Systems. Journal of Thermal Science and Technology, 38(2), 51-61.
Farooq, M., Hamayoun, A., Naqvi, M., Nawaz, S., Usman, M., Naqvi, S. R., Imran, M., Nadeem, R., Razi, A., Turan, A., Pettinau, A., Andresen, J. M. (2020). Thermodynamic Performance Analysis of Hydrofluoroolefins (HFO) Refrigerants in Commercial Air-Conditioning Systems for Sustainable Environment, Processes, 8(2), 187. https://doi.org/10.3390/pr8020187
Kumaş, K., Akyüz, A., Güngör, A.(2019). The Determination of Carbon Footprint for Higher Education Units of Burdur Mehmet Akif Ersoy University in Bucak Campus. Omer Halisdemir University Journal of Engineering Sciences. 8(2), 1277-1291.https://doi.org/10.28948/ngumuh.598212
Kumaş, K., Akyüz, A., Zaman, M., Güngör. A. (2019). Carbon Footprint Determination for a Sustainable Environment: MAKÜ Bucak School of Health Example. El-Cezerî Journal of Science and Engineering. 6(1),108-117. https://doi.org/10.31202/ecjse.459478
Llopis, R., Sánchez, D., Cabello, R., Catalán -Gil, J., Nebot-Andrés, L. (2017). Experimental analysis of R-450A and R-513A as replacements of R-134a and R-507A in a medium temperature commercial refrigeration system. International Journal of Refrigeration. 84,52–66. https://doi.org/10.1016/j.ijrefrig.2017.08.022
Maiorino, A., Aprea, C., Del Duca, M. G., Llopis, R., Sánchez, D., Cabello, R. (2018). R-152a as an alternative refrigerant to R-134a in domestic refrigerators: An experimental analy