The Effect of Span Length on Clinical Performance of Y-TZP Fixed Partial Dentures

-

Sayfa
1–1
Yayın Tarihi
2016-05-13
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures.
📊
Temel Bulgular & Veri:Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients.
💡
Sonuç & Katkı:Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:All-ceramic · fixed dental prostheses · long span

Özet

Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures. Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p<0.05). Results: No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70.92(±40.02) μm for extended span length Y-TZP FPDs and 88.01(±54.34) μm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area (p<0.05). There was no significant difference in relation to span length. Conclusion: Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.

Abstract

Objectives: The aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures. Methods: Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using ‘California Dental Association Criteria’, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. “Kruskal Wallis” and “Wilcoxon Signed Ranks” tests were used for statistical analysis (p

🔖