Dergiler / Marmara Medical Journal / 2002 / Cilt: 15 - Sayı: 4

NONINVASIVE 3-DIMENSIONAL ELECTRON BEAM COMPUTED TOMOGRAPHY ANGIOGRAPHY RENAL ARTERIES

Sayfa
267–272
Yayın Tarihi
2016-12-03
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Ultrafast EBCT with its axial images and several three dimensional techniques, is easy to apply, functional and accurate for renal vascular anatomy and renal artery stenosis (RAS) and useful for detection of extension of the trauma and intravascular tumor in partial nephrectomy.Key Words: EBCT, Three dimension, Angiography, UPJ (ureteropelvic junction) stenoses, Trauma.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Three dimensional electron beam computed tomography (EBCT) angiography is a useful technique for the depiction of renal artery lesions and for vascular variants.
📊
Temel Bulgular & Veri:Generic advantages of ultrafast tomography and thin slice imaging, are registered volume data set with overlapping reconstructions to reduce partial volume effect and effective contrast medium utilization.
💡
Sonuç & Katkı:Ultrafast EBCT with its axial images and several three dimensional techniques, is easy to apply, functional and accurate for renal vascular anatomy and renal artery stenosis (RAS) and useful for detection of extension of the trauma and intravascular tumor in partial nephrectomy.Key Words: EBCT, Three dimension, Angiography, UPJ (ureteropelvic junction) stenoses, Trauma.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Three dimensional electron beam computed tomography (EBCT) angiography is a useful technique for the depiction of renal artery lesions and for vascular variants. Generic advantages of ultrafast tomography and thin slice imaging, are registered volume data set with overlapping reconstructions to reduce partial volume effect and effective contrast medium utilization. Ultrafast EBCT with its axial images and several three dimensional techniques, is easy to apply, functional and accurate for renal vascular anatomy and renal artery stenosis (RAS) and useful for detection of extension of the trauma and intravascular tumor in partial nephrectomy.Key Words: EBCT, Three dimension, Angiography, UPJ (ureteropelvic junction) stenoses, Trauma.

🔖

Bu Makaleye Atıf Yap

Tepe, S., Memişoğlu, E., Kural, A. R. (2016). NONINVASIVE 3-DIMENSIONAL ELECTRON BEAM COMPUTED TOMOGRAPHY ANGIOGRAPHY RENAL ARTERIES. Marmara Medical Journal, Cilt: 15 - Sayı: 4, 267–272. https://ajindex.com/articles/688682

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Gould RG. Principles of ultra fast computed tomography: Historical aspects, mechanism of action, and scanner characteristics. In: Stanford W, Rumberger J, eds. UFCT in Cardiac Imaging. Principles and Practice. Hew York: Futura Publishing Company Inc.,:4-12. linuma TA, Tateno Y, Umegaki Y, et al. Proposed system for ultrafast CT. J Comput Assist Tomogr 1977:1,-494-499. Boyd DP. Future technologies, transmission CT. In: Hewton TH, Potts DG, eds. Radiology of the Skull and Brain. Volume 5. Technical Aspects of CT. St. Louis, MO: CV Mosby Co., 1981.
  2. Barnes GT, Lakshminarayanan AV. Conventional and spiral CT. Physical principles and image quality considerations. In: Lee JR T, SageI SS, Stanley RJ, Heiken JP, eds. Computed Body Tomography with MR! Correlation. Volume I. Philadelphia PA: Lippincott-Raven, 1998:6-7.
  3. Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during CT: Effective doses at multidetector row CT and electron beam CT. Radiology 2003; 226:145-152.
  4. Johnson PT, Halpern EJ, Ruszyk BS, et al. Renal artery stenosis: CT angiography- comparison of real-time volume rendering and maximum intensity projection algorhythms. Radiology 1999;21 /:337-343.
  5. Ruszyk BS, Heath DG, Hey DR, et al. CT angiography with volume rendering: imaging findings. AJR 1995; 165:445-448.
  6. Smith PA, Fishman ER. CT angiography: renal applications. In: Ferris EJ, Waltman AC, Fishman ER, Polak JF, Potchen EJ, eds. Syllabus: A Categorical Course in Diagnostic Radiology-Vascular Imaging. Oak Brook, III: Radioloqical Society of Horth America, 1998; 35-45.
  7. Ruszyk BS, Fishman ER. Technical aspects of CT angiography. Semin Ultrasound CT MR 1998; 19:383-393.
  8. Smith PA, Fishman ER. Three dimensional CT angiography: renal applications. Semin Ultrasound CT MR 1998; 19:413-424.
  9. I I. Rattee R, Beek F,de Lange E, et al. Renal artery stenosis: detection and quantification with spiral CT angiography and optimized digital substraction angiography. Radiology 1997,205: 121-127.
  10. Platt J, Ellis J, Rorobkin M, et al. Helical CT evaluation of potential kidney donors: findings in 154 subjects. AJR 1997; 169:1325-1330. Rubin GD. Spiral (helical) CT of the renal vasculature. Semin Ultrasound CT MR 1996; I 7:374-1397.
  11. Smith PA, Rainer LE, Lynch FC, et al. Role of CT angiography in the preoperative evaluation for laparoscopic nephrectomy. Radiographies 1998; 18:589-601.
  12. Herts BR, Coll DM, Lieber ML, et al. Triphasic helical CT of the kidneys: contribution of vascular phase scanning in patients before