Dergiler / Journal of Thermal Engineering / 2017 / Cilt: 3 - Sayı: 5

PERFORMANCE ANALYZING OF AN ORGANIC RANKINE CYCLE UNDER DIFFERENT AMBIENT CONDITIONS

Sayfa
1498–1504
Yayın Tarihi
2017-09-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Simulation results show that that Organic Rankine Cycle performance can be sensitive to the seasonal and daily variation of the ambient conditions.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The goal of this study is to develop a thermodynamic model in order to show the effect of ambient conditions on performance of an Organic Rankine Cycle based power generation system.
📊
Temel Bulgular & Veri:After that, simulation studies are iteratively carried out to determine the performance of the considered system under variation of ambient conditions such as dry bulb temperature and relative humidity.
💡
Sonuç & Katkı:Simulation results show that that Organic Rankine Cycle performance can be sensitive to the seasonal and daily variation of the ambient conditions.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Organic Rankine cycle · Cooling tower · Ambient Conditions

Abstract

The goal of this study is to develop a thermodynamic model in order to show the effect of ambient conditions on performance of an Organic Rankine Cycle based power generation system. This system is simply consisted of a turbine, a condenser, a boiler, pumps and a cooling tower. Each component in this system is modeled based on energy and mass balance equations. Then, the system model is obtained with integration of component models. After that, simulation studies are iteratively carried out to determine the performance of the considered system under variation of ambient conditions such as dry bulb temperature and relative humidity. Simulation results show that that Organic Rankine Cycle performance can be sensitive to the seasonal and daily variation of the ambient conditions.

🔖

Bu Makaleye Atıf Yap

AKKAYA, A. V. (2017). PERFORMANCE ANALYZING OF AN ORGANIC RANKINE CYCLE UNDER DIFFERENT AMBIENT CONDITIONS. Journal of Thermal Engineering, Cilt: 3 - Sayı: 5, 1498–1504. https://ajindex.com/articles/682105

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Tchanche, B., Petrissans, M., Papadakis, G., 2014, Heat resource and organic Rankine cycle machine, Renewable and Sustaunable Energy Reviews, vol, 39: p. 1185-1199
  2. Velez, F., Segovia, J., Martin, C., Antolin G., Chejne F., Quijano,A., 2012, A technical, economical and market review of organic Rankine cycles for the conversion of low-grade heat for power generation, Renewable and Sustainable Energy Reviews, vol. 16: p. 4175-4189
  3. Ziviani, D., Beyene, A., Venturini, M., 2014, Advances and challenges in ORC systems modeling for low grade thermal energy recovery, Applied Energy, vol. 121: p. 79-95
  4. Joan, B., Jesús, L., Eduardo, L., Silvia, R., Alberto, C., 2008, Modelling and optimisation of solar organic Rankine cycle engines for reverse osmosis desalination, Applied Thermal Engineering, vol. 28: p. 2212–2226
  5. Pei, G., Li, J., Ji, J., 2010, nalysis of low temperature solar thermal electric generation using regenerative organic Rankine cycle, Applied Thermal Engineering, vol. 30: p. 998–1004
  6. Liu, B., Chien, K., Wang, C., 2004, Effect of working fluids on organic Rankine cycle for waste heat recovery, Energy, vol. 29: p. 1207–1217
  7. Dai, Y., Wang, J., Gao, L., 2009, Parametric optimization and comparative study of organic Rankine cycle (ORC) for low grade waste heat recovery, Energy Conversion and Management, vol. 50: p. 576–582
  8. Srinivasan, K., Mago, P., Krishnan, S.,2010, Analysis of exhaust waste heat recovery from a dual fuel low temperature combustion engine using an organic Rankine cycle, Energy, vol. 35: p. 2387-2399
  9. Zhou, N., Wang, X., Chen, Z., Wang, Z., 2013, Experimental study on Organic Rankine Cycle for wate heat recovery from low-temperature flue gas, Energy, vol. 55: p. 216-225
  10. Invernizzi, C., Iora, P., Silva, P.,2007, Bottoming micro-Rankine cycles for micro-gas turbines, Applied Thermal Engineering, vol. 27: p. 100–110
  11. Martina, P., Shane, W., Philip, O., 2010, Evaluation of energy efficiency of various biogas production and utilization pathways, Applied Energy, vol. 87: p. 3305–3321
  12. Gu, Z., Sato, H., 2002, Performance of supercritical cycles for geothermal binary design, Energy Conversion and Management, vol. 43: p. 961–971
  13. Franco, A., Villani, M.,2009, Optimal design of binary cycle power plants for water-dominated, medium-temperature geothermal fields, Geothermics, vol. 38: p. 379–391
  14. Hung, T., 2001, Waste heat recovery of organic Rankine cycle using dry fluids, E