Dergiler / Düzce Üniversitesi Bilim ve Teknoloji Dergisi / 2016 / Cilt: 4 - Sayı: 2

Ev Tipi Soğutucuda Yağ Hazneli Kondenserin Sistem Performansı Üzerine Etkisinin İncelenmesi

Investigation of The Effect of A Household Refrigerator Condenser With Oil Tank On The System Performance

Sayfa
475–485
Yayın Tarihi
2016-03-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Yağ soğutmalı kondenserde yağ miktarı artıkça kondenser performansının arttığı ve enerji tüketiminin azaldığı tespit edilmiştir.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Soğutma ve soğutma teknolojisine olan ihtiyacın hızla artığı günümüzde soğutma sistemlerinden birçok alanda yararlanılmaktadır.
📊
Temel Bulgular & Veri:Bununla birlikte günümüzde artan enerji ihtiyacına bağlı olarak soğutma sistemlerinden verimli bir şekilde yararlanma ve enerji tasarrufu sağlamak oldukça önem kazanmaktadır.
💡
Sonuç & Katkı:Yağ soğutmalı kondenserde yağ miktarı artıkça kondenser performansının arttığı ve enerji tüketiminin azaldığı tespit edilmiştir.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Hava soğutmalı kondenser · Yağ soğutmalı kondenser · STK

Özet

Soğutma ve soğutma teknolojisine olan ihtiyacın hızla artığı günümüzde soğutma sistemlerinden birçok alanda yararlanılmaktadır. Bununla birlikte günümüzde artan enerji ihtiyacına bağlı olarak soğutma sistemlerinden verimli bir şekilde yararlanma ve enerji tasarrufu sağlamak oldukça önem kazanmaktadır. Ev tipi soğutucularda sistemin verimini artırmanın bir yolu da kondenser kapasitesinin artırılmasıdır. Bu çalışmada ilk olarak doğal taşınımlı telli-boru tip kondenserin performans testi yapılmıştır. Daha sonra kondenser bir tankının içine yerleştirilerek tankın içeresine sırasıyla 2.5, 5, 7.5 ve 10 lt miktarlarında nebati yağ eritilip doldurulmuş ve sistemin performans testleri yapılmıştır. Bu çalışmada ev tipi soğutucu on-off olarak 2 saat boyunca çalıştırılmıştır ve ölçümler 5’er dakika aralıklarla alınmıştır. Yağ soğutmalı kondenserde yağ miktarı artıkça kondenser performansının arttığı ve enerji tüketiminin azaldığı tespit edilmiştir. Hava soğutmalı kondenser kullanarak yüksüz çalıştırıldığında STK değeri 2.38 ve enerji tüketimi 110 Wh iken, yağ soğutmalı kondenser 10 lt yağ doluyken STK değeri 2.72’ye çıkmış ve enerji tüketimi ise 50 Wh’e inmiştir. Hava soğutmalı kondenser kullanarak yüklü çalıştırıldığında STK değeri 2.13 ve enerji tüketimi 120 Wh iken, yağ soğutmalı kondenser 10 lt yağ doluyken STK değeri 2.58’e çıkmış ve enerji tüketimi ise 60 Wh’e inmiştir.

Abstract

Today, the need for cooling and cooling technologies are growing fast and they are used in many areas. In this study, first the performance test of a natural circulation wire-tube condenser was tested. Then the condenser was placed into a tank and 2.5, 5, 7.5 and 10 liters of melted vegetable oil was filled into the tank. Performance tests of the system were performed at both loaded and unloaded conditions and also under both continuous and on/off operation. Experimental results showed that as the amount of oil in the oil-cooled condenser increases, the condenser capacity and cooling capacity also increase, and also the energy consumption decreases. The energy consumption in unloaded operation of air-cooled condenser for 1 hour was measured as 110 Wh, and it decreased to 50 Wh for oil-cooled condenser filled with 10 liters of oil. The energy consumption in loaded operation of air-cooled condenser for 1 hour was measured as 120 Wh, and it decreased to 60 Wh for oil-cooled condenser filled with 10 liters of oil. On the other hand the COP of the system in unloaded operation of aircooled condenser was calculated as 2.38, and it increased to 2.72 for oil-cooled condenser filled with 10 liters of oil. For loaded operation of air-cooled condenser was calculated as 2.13, and it increased to 2.58 for oil-cooled condenser filled with 10 liters of oil.

🔖

Bu Makaleye Atıf Yap

KILIÇASLAN, E., ACAR, B., ARICIOĞLU, M. (2016). Ev Tipi Soğutucuda Yağ Hazneli Kondenserin Sistem Performansı Üzerine Etkisinin İncelenmesi. Düzce Üniversitesi Bilim ve Teknoloji Dergisi, Cilt: 4 - Sayı: 2, 475–485. https://ajindex.com/articles/661035

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (4)

  1. M. Kadayıfçı, Bacalı doğal taşınımlı yoğuşturucunun ev tipi soğutucuların performansına etkisi, Yüksek Lisans Tezi, Karabük Üniversitesi, Karabük-Türkiye, (2011).
  2. R.A. Clark, R.N. Smith, M.K. Jensen, An experimental study of waste heat recovery from a residential refrigerator, Energy Conversion Engineering Conference Proceedings of the 31st Intersociety, Washington-ABD, (1996) 1887. C. Wen-Long, M. Bao-Jun, L. Yi-Ning, H. Yong-Hua, Y.A. Xu-Dong Energy 36(10) (2011) 579. A. Akdoğan, Bir soğutma sistemindeki kondenser kapasitesinin değiştirilmesinin enerji ve ekserji analizleri ile incelenmesi, Yüksek Lisans Tezi, Zonguldak Karaelmas Üniversitesi,
  3. Zonguldak-Türkiye (2007).
  4. G. E. Stinson, C.J. Stuman, D.J. Warburton, Journal of Agriculture Engineering 36(4) (1987) 275. H.W. Alex, J.W. Jones Applied Energy 57(4) (1997) 271. M. Goto, S. Ohuchinda, T. Agata, A energy saving methodology for arge air-conditioning systems-performance of an additional condenser and its application to a hot water supply, In proceedin4gs of international symposium on ecotopic science, Kopenhang-Danimarka, (2007) 189. S.N. Sapali, S.M. Pise, A.T. Pise, D.V. Ghewade (2014) DOI: 10.1016/j.csite.2014.09.003. Patil, P. A. Experımental Heat Transfer 25(2) (2012) 77. J.Tissot, P. Boulet, F. Trinquet, L. Fournaison, M. Lejeune, F. Liaudet Int. Jour. of ref. 38(2) (2014) 93. E. Hajidavalloo, H.Eghtedari Int. Jour. of Ref. 33(5) (2010) 982.