Düşük astigmatlı olgularda torik ve yumuşak sferik kontakt lenslerin görsel performans ve wavefront aberasyonlar üzerine etkileri

Effects of toric and soft spherical contact lenses on visual performance and wavefront aberrations in patients with low levels of astigmatism

Sayfa
22–25
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Her iki lens grubu arasında anlamlı fark saptanmadı.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Düşük astigmatizmalı hastalarda kullanılan torik ve sferik kontakt lenslerin görme keskinliği ve wavefront aberasyonlar üzerine etkilerini araştırmak.Gereç ve Yöntem: Prospektif olarak yapılan bu çalışmaya -1,25 dioptri (D) ve altında silindirik refraksiyon kusuru bulunan 14 kontakt lens kullanıcısının 24 gözü dahil edildi.
📊
Temel Bulgular & Veri:Çalışmaya katılan 24 göze 1 hafta arayla yumuşak sferik (Lotrafilcon B) ve torik (Galyfilcon A) kontakt lensler denendi.
💡
Sonuç & Katkı:Her iki lens grubu arasında anlamlı fark saptanmadı.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Düşük astigmatizmalı hastalarda kullanılan torik ve sferik kontakt lenslerin görme keskinliği ve wavefront aberasyonlar üzerine etkilerini araştırmak.Gereç ve Yöntem: Prospektif olarak yapılan bu çalışmaya -1,25 dioptri (D) ve altında silindirik refraksiyon kusuru bulunan 14 kontakt lens kullanıcısının 24 gözü dahil edildi. Çalışmaya katılan 24 göze 1 hafta arayla yumuşak sferik (Lotrafilcon B) ve torik (Galyfilcon A) kontakt lensler denendi. Olguların kontakt lensleri takmadan önce ve taktıktan 8 saat sonra en iyi görme keskinlikleri ölçüldü, kontrast duyarlılık ölçümleri, korneal topografi ve wavefront analizleri yapıldı. Altı milimetre pupil çapından aberasyonları ölçmek için Zernike katsayıları kullanıldı. Toplam ve yüksek sıralı aberasyonların RMS değerleri, sferik ve koma aberasyonlar ölçüldü.Sonuçlar: Olguların ortalama sferik refraksiyon değerleri -2,52±1,25 (-0,50 - -6,0) D idi. Ortalama düzeltilmiş en iyi görme keskinliği her iki kontakt lens ile de gözlük camları ile yapılan ölçüme göre artmıştı (p=0,017), fakat kontakt lensler arasında anlamlı bir fark gözlenmedi (p>0,470). Ortalama yüksek frekans kontrast duyarlılık değeri torik kontakt lens ile en düşük bulundu (p=0,038). Ortalama yüksek sıralı RMS değeri kontakt lens kullanımı ile artmıştı (p=0,021). Kontakt lensler arasında ise anlamlı bir farklılık yoktu (p>0,05). Ortalama sferik aberasyon değerleri açısından gözlük camları, yumuşak sferik ve torik kontakt lensler arasında fark gözlenmedi (p>0,05). Kontakt lens kullanımı ile koma aberasyon değerlerinin arttığı görüldü (p=0,041). Kontakt lens türleri arasında koma aberasyon değerleri açısından farklılık yoktu (p>0,05).Tartışma: Bu çalışmada düşük miyop astigmatı bulunan olgularda yumuşak sferik ve torik kontakt lenslerin gözlük camlarına göre görme keskinliğini arttırdığı, yüksek frekanslarda kontrast duyarlılık değerlerini düşürdüğü, toplam yüksek sıralı aberasyon ve koma aberasyon miktarlarını arttırdığı tespit edildi. Her iki lens grubu arasında anlamlı fark saptanmadı.

Abstract

Purpose: To investigate the effects of toric and soft spherical contact lenses on the visual performance and wavefront aberrations in cases of low astigmatism.Material and Method: Twenty-four eyes of 14 contact lens users with cylindirical refractive error of -1.25 diopters or less were included in this prospective study. The subjects wore spherical (lotrafilcon B) and toric (galyfilcon A) lenses for eight hours with a one-week interval. The best-corrected visual acuity and contrast sensitivity were measured before and after 8 hours of contact lens wear. Corneal topography and wavefront analysis were also performed. Zernike coefficients were used to calculate the aberrations at a 6-mm pupil diameter. Total and higher-order root mean square (RMS) values as well as spherical and coma aberrations were measured.Result: The mean spherical refractive error of the cases was -2.52±1.25 (range: from -0.50 to -6.0) D. The mean best- corrected visual acuity was significantly higher with both types of contact lenses than with glasses (p=0.017), however, no statistical difference was observed between the two types of contact lenses (p=0.470). The mean high-frequency contrast sensitivity value was lower with toric lenses (p=0.038). The mean higher-order RMS value was higher with both types of contact lenses (p=0.021), but with no difference between them (p>0.05). The mean spherical aberration value did not differ among glasses, toric or soft spherical contact lenses (p>0.05). The mean coma aberrations were high with both types of contact lenses (p=0.041); no difference was observed between the two lens types (p>0.05). Discussion: In this study, it was demonstrated that in cases of low astigmatism, soft spherical and toric contact lenses increase visual acuity, total higher-order aberrations, and coma aberrations, but decrease high-frequency contrast sensitivity. There was no difference between the two types of contact lenses.

🔖

Bu Makaleye Atıf Yap

BİLKAY, H., GÖKMEN, S. A., CAN, İ., GÜRDAL, C., SARAÇ, Ö., TAKMAZ, T. (2022). Düşük astigmatlı olgularda torik ve yumuşak sferik kontakt lenslerin görsel performans ve wavefront aberasyonlar üzerine etkileri. Türk Oftalmoloji Dergisi, Cilt: 41 - Sayı: 1, 22–25. https://ajindex.com/articles/638362

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Hong X, Himebaugh N, Thibos LN. On-eye evaluation of optical performance of rigid and soft contact lenses. Optom Vis Sci. 2001;78:872-80. [Abstract] 2. Richdale K, Berntsen DA, Mack CJ, Merchea MM, Barr JT. Visual acuity with spherical and toric soft contact lenses in low- to moderate-astigmatic eyes. Optom Vis Sci. 2007;84:969-75. [Abstract] 3. Cabrera JV, Rodriguez JB. Vision with disposable toric contact lenses and daily-wear toric contact lenses. Ophthalmic Physiol Opt. 1998;18:66-74. [Abstract] 4. Applegate RA, Ballentine C, Gross H, Sarver EJ, Sarver CA. Visual acuity as a function of Zernike mode and level of root mean square error. Optom Vis Sci. 2003;80:97-105. [Abstract] 5. Lombardo M, Lombardo GJ. Wave aberration of human eyes and new descriptors of image optical quality and visual performance. Cataract Refract Surg. 2010;36:313-31. [Abstract] 6. Roberts B, Athappilly G, Tinio B, Naikoo H, Asbell P. Higher order aberrations induced by soft contact lenses in normal eyes with myopia. Eye Contact Lens. 2006;32:138-42. [Abstract] 7. David AB, Mohinder MM, Kathryn Richdale, Carla JM, Joseph T. Barr. Higher-Order Aberrations when wearing Sphere and Toric Soft Contact Lenses. Optom Vic Sci. 2009;86:115-22. [Abstract] 8. Mcalinden C, Moore JE, McGilligan VE, Moore TC. Spherical aberration and higher order aberrations with Balafilcon A (PureVision) and Comfilcon A (Biofinity). Graefes Arch Clin Exp Ophthalmol. 2010;6. [Abstract] 9. Bertsen DA, Merchea MM, Richdale K, Mack CJ, Barr JT. Higher-order aberrations when wearing sphere and toric soft contact lenses. Optom Vis Sci. 2009;86:115-22. [Abstract] 10. Dorronsoro C, Barbero S, Liorente L, Marcos S. On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry. Optom Vis Sci. 2003;80:115-25. [Abstract] 11. Jiang H, Wang D, Yang L, Xie P, He JC. A comparison of wavefront aberrations in eyes wearing different types of soft contact lenses. Optom Vis Sci. 2006;83:769-74. [Abstract] 12. Hiraoka T, Okamoto C, Ishii Y, Kakita T, Oshika T. Contrast sensitivity function and ocular higher-order aberrations following overnight orthokeratology. Optom Vis Sci. 2007;48:550-6. [Abstract]