Kuru göz hastalarında optik koherans tomografi ile gözyaşı menisküs parametrelerinin değerlendirilmesi

Evaluating of tear meniscus parameters with optical coherent tomography in dry-eye patients

Sayfa
258–262
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Tar­t fl­ma: Kuru göz tanısı koymada GKZ ve OSDI ile semptom sorgulamasının, Schirmer-I testine kıyasla daha faydalı olduğu, OKT ile ölçülen gözyaşı menisküs parametrelerinin tanı koymada tek başına yeterli olmamakla birlikte, tedaviye yanıtı izlemde özellikle AGMY ve AGMAnın yardımcı olabileceği ve bu iki parametrenin OSDI skoru ile korelasyonunun semptom sorgulamada objektifliği artırabileceği düşünüldü. (Turk J Ophthalmol 2013; 43: 258-62)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Özet Amaç: Optik Koherans Tomografi (OKT) ile kuru göz hastalarında ölçülen gözyaşı menisküs parametrelerinin suni gözyaşı tedavisi ile değişimi ve OKT parametrelerinin geleneksel kuru göz testleri ile korelasyonun değerlendirilmesi amaçlandı.
📊
Temel Bulgular & Veri:Ge­reç ve Yön­tem: Yeni tanı alan 32 kuru göz hastasının sağ gözleriyle, 30 sağlıklı göz çalışmaya dahil edildi.
💡
Sonuç & Katkı:Tar­t fl­ma: Kuru göz tanısı koymada GKZ ve OSDI ile semptom sorgulamasının, Schirmer-I testine kıyasla daha faydalı olduğu, OKT ile ölçülen gözyaşı menisküs parametrelerinin tanı koymada tek başına yeterli olmamakla birlikte, tedaviye yanıtı izlemde özellikle AGMY ve AGMAnın yardımcı olabileceği ve bu iki parametrenin OSDI skoru ile korelasyonunun semptom sorgulamada objektifliği artırabileceği düşünüldü. (Turk J Ophthalmol 2013; 43: 258-62)
🔬Tür:Araştırma Makalesi
📍Kapsam:2013 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Özet Amaç: Optik Koherans Tomografi (OKT) ile kuru göz hastalarında ölçülen gözyaşı menisküs parametrelerinin suni gözyaşı tedavisi ile değişimi ve OKT parametrelerinin geleneksel kuru göz testleri ile korelasyonun değerlendirilmesi amaçlandı. Ge­reç ve Yön­tem: Yeni tanı alan 32 kuru göz hastasının sağ gözleriyle, 30 sağlıklı göz çalışmaya dahil edildi. Hastaların; görme keskinliği, biomikroskopik muayenesi, Schirmer-I testi, gözyaşı kırılma zamanı (GKZ), OKT ile alt gözyaşı menisküs parametreleri değerlendirildi. Oküler yüzey hastalığı indeksi (OSDI) ile semptom sorgulaması yapıldı. Ölçümler; suni gözyaşı ile tedavinin 10. günü ve 1.ayında tekrarlandı. Alt gözyaşı menisküs yüksekliği (AGMY),derinliği (AGMD), kesitsel alanı (AGMA) ve kornea ile yaptığı açı (α açısı) ölçüldü. Kuru göz grubunda tedavi öncesi gözyaşı menisküs değerleri kontrol grubuyla kıyaslandı, geleneksel kuru göz testleri ve OKT değerleri arasındaki korelasyon değerlendirildi. Tedaviyle kuru göz testleri ve OKT değişimleri gözlemlendi. So­nuç­lar: Hastaların yaş ortalamaları ve cinsiyet dağılımları açısından gruplar arasında istatistiksel olarak anlamlı bir fark bulunmadı. Tedavi öncesi ortalama Schirmer-I testi, GKZ ve OSDI skorları iki grup arasında anlamlı farklıydı. OKT parametrelerinden AGMY ve AGMA kontrol grubunda yüksek olacak şekilde iki grup arasında anlamlı farklı idi. Kuru göz grubunda tedavi öncesi ortalama OSDI skoruyla AGMY ve AGMA arasında istatistiksel olarak anlamlı negatif korelasyon varken, diğer tanı testleri ile OKT parametreleri arasında anlamlı korelasyon saptanmadı. OKT parametrelerinden AGMD ve α açısında tedavi süresince anlamlı değişiklik gözlenmezken; AGMY ve AGMA nın 1. ay değerleri tedavi öncesi ve 10. gün değerlere kıyasla anlamı şekilde yüksek olduğu görüldü. Tar­t fl­ma: Kuru göz tanısı koymada GKZ ve OSDI ile semptom sorgulamasının, Schirmer-I testine kıyasla daha faydalı olduğu, OKT ile ölçülen gözyaşı menisküs parametrelerinin tanı koymada tek başına yeterli olmamakla birlikte, tedaviye yanıtı izlemde özellikle AGMY ve AGMAnın yardımcı olabileceği ve bu iki parametrenin OSDI skoru ile korelasyonunun semptom sorgulamada objektifliği artırabileceği düşünüldü. (Turk J Ophthalmol 2013; 43: 258-62)

Abstract

Pur­po­se: To evaluate the changes in meniscus parameters with optical coherence tomography (OCT) after treatment and considethe correlation between the OCT parameters and dry-eye tests. Ma­te­ri­al and Met­hod: Thirty-two dry-eye patients and 30 healthy individuals were included. Visual acuities, biomicroscopic evaluation, Schirmer-I test, tear-break-up time (T-BUT), and lower-tear meniscus parameters measured with OCT were evaluatedOcular surface disease index (OSDI) was performed. The measurements were repeated on the 10th day and 1st month of the treatmentLower tear meniscus height (LTMH), depth (LTMD), area (LTMA) and α-angle were measured. The tear meniscus parameters othe dry-eye group were compared with the control group before treatment, and the correlation between the dry-eye tests and OCT measurements were evaluated. The change in the results of the dry-eye tests and OCT measurements with treatment were assessed. Re­sults: There was statistically no significant difference between the age and gender of the patients in groups. Before treatment the mean Schirmer-I test, TBUT and OSDI scores were different. The LTMH and LTMA were higher in the control group. In the dry-eye group before treatment, there was a negative correlation between the OSDI score and OCT parameters, however, no meaningful correlation was observed between any other test and OCT parameters. Although there were no change in LTMD and α-angle with treatment, the 1st month valueof LTMH and LTMA were significantly higher from the pre-treatment and 10th day values. Dis­cus­si­on: When diagnosing dry-eye, TBUT and OSDI scores were found to be more effective compared to Schirmer-I test for the diagnosis of dry eye. Although not adequate by itself, tear meniscus parameters measured with OCT, LTMH and LTMA, may be helpfufor evaluating the efficacy of treatment, and the correlation of these two parameters with the OSDI score may increase the objectivity while questioning the symptoms. (Turk J Ophthalmol 2013; 43: 258-62)

🔖

Bu Makaleye Atıf Yap

SOYUGELEN, G. D., BOSTANCI, B. C., CAN, İ., GÜRDAL, C., SARAÇ, Ö. (2022). Kuru göz hastalarında optik koherans tomografi ile gözyaşı menisküs parametrelerinin değerlendirilmesi. Türk Oftalmoloji Dergisi, Cilt: 43 - Sayı: 4, 258–262. https://ajindex.com/articles/638139

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (17)

  1. Lemp MA. Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes. CLAO J. 1995;21:221-32. Nelson JD. A clinician looks at the tearfilm. Adv Exp Med Biol. 1998;438:1-9. Holly FJ. Physical chemistry of the normal and disordered tear film. Trans Ophthalmol Soc UK. 1985;104:374-80.
  2. Mishima S, Gasset A, Klyce SD Jr, Baum JL. Determination of tear volume and tear flow. Invest Ophthalmol. 1966;5:264-76.
  3. Lucca JA, Nunez JN, Farris RL. A comparison of diagnostic tests for ker- atoconjunctivitis sicca: lactoplate, Schirmer, and tear osmolarity. CLAO J. 1990;16:109-12.
  4. Patel S, Perez-Santonja JJ, Alio JL, Murphy PJ. Corneal sensitivity and some properties of tear film after laser in situ keratomileusis. J Refract Surg. 2001;17:17-24.
  5. Palakuru JR, Wang J, Aquavella JV. Effect of blinking on tear dynamics. Invest Ophthalmol Vis Sci. 2007;48:3032-7.
  6. Yokoi N, Bron AJ, Tiffany JM, Maruyama K, Komuro A, Kinoshita S. Relationship between tearvolume and tear meniscus curvature. Arch Ophthalmol.2004;122:1265-9.
  7. Mainstone JC, Bruce AS, Golding TR. Tear meniscus measurement in the diagnosis of dry eye. Curr Eye Res. 1996;15:653-61.
  8. Uchida A, Uchino M, Goto E, et al. Noninvasive interference tear menis- cometry in dry eye patients with Sjogren syndrome. Am J Ophthalmol. 2007;144:232-7.
  9. Port MJ, Asaria TS. The assessment of human tear volume. J Br Contact Lens Assoc. 1990;13:76-82.
  10. Yokoi N, Bron AJ, Tiffany JM, Kinoshita S. Reflective meniscometry: a new field of dry eye assessment. Cornea. 2000;19:37-43.
  11. Oguz H, Yokoi N, Kinoshita S. The height and the radius of the tear meniscus and methods for examining these parameters. Cornea. 2000;19:497-500.
  12. Wang J, Aquavella J, Palakuru J, Chung S, Feng C. Relationships between central tear film thickness and tear menisci of the upper and lower eyelids. Invest Ophthalmol Vis Sci. 2006;47:4349-55
  13. Yuan Y, Chen JW, Tao A, et al. Reduced tear meniscus dynamics in dry eye patients with aqueous tear deficiency. Am J Ophthalmol. 2010;149:932-8.
  14. Shen M, Li J, Wang J, et al. Upper and lower tear menisci in the diagnosis of dry eye. IOVS 2009;50:2722-6.
  15. Doğru İ, Toklu Y, Saraç Ö, Çakmak HB. Punktum Tıkacı Uygulanan Kuru Göz Hastalarındaki Uzun Dönem Sonuçlarımız. Türk Oftalmoloji Gazetesi. 2011;41:225-9
  16. Han SB, Hyon JY, Woo SJ, Lee JJ, Kim TH, Kim KW. Prevalence of dry eye disease in an elderly Korean population. Arch Ophthalmol. 2011;129:633-8
  17. Uchino M, Nishiwaki Y, Michikawa T, et al. Prevalence and risk factors of d