Dergiler / Türk Kardiyoloji Derneği Arşivi / 2014 / Cilt: 42 - Sayı: 4

Comparison of gated myocardial perfusion SPECT, echocardiography and equilibrium radionuclide ventriculography in the evaluation of left ventricle contractility

Sol ventrikül kontraktil fonksiyonlarının değerlendirilmesinde equilibrium radyonüklid ventrikülografi, ekokardiyografi ve miyokart perfüzyon gated SPECT görüntülemenin karşılaştırılması

Sayfa
349–357
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Olguların GSPECT ile hesaplanan ortalama SVEF ile ERVG verileri arasında iyi derecede korelasyon bulundu.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Çalışmamızda, sol ventrikül (SV) fonksiyonlarının değerlendirilmesinde miyokart perfüzyon gated SPECT (GSPECT) yönteminin güvenilirliği araştırıldı, GSPECT ile hesaplanan sol ventrikül ejeksiyon fraksiyonu (SVEF) ortalaması planar equilibrium gated radyonüklid ventrikülografi (ERVG) ve ekokardiyografi (EKO) ile elde edilen değerlerle karşılaştırıldı.
📊
Temel Bulgular & Veri:Çalışma planı: Koroner arter hastalığı (KAH) şüphesi olan miyokart perfüzyonu ve SV fonksiyonlarının değerlendirilmesi için iki gün Tc99m-MIBI protokolü ile GSPECT ve ERVG görüntülemeleri yapılan 48 hasta geriye dönük olarak incelendi.
💡
Sonuç & Katkı:Bulgular: Olguların GSPECT ile hesaplanan ortalama SVEF ile ERVG verileri arasında iyi derecede korelasyon bulundu.
🔬Tür:Araştırma Makalesi
📍Kapsam:48 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Çalışmamızda, sol ventrikül (SV) fonksiyonlarının değerlendirilmesinde miyokart perfüzyon gated SPECT (GSPECT) yönteminin güvenilirliği araştırıldı, GSPECT ile hesaplanan sol ventrikül ejeksiyon fraksiyonu (SVEF) ortalaması planar equilibrium gated radyonüklid ventrikülografi (ERVG) ve ekokardiyografi (EKO) ile elde edilen değerlerle karşılaştırıldı. Çalışma planı: Koroner arter hastalığı (KAH) şüphesi olan miyokart perfüzyonu ve SV fonksiyonlarının değerlendirilmesi için iki gün Tc99m-MIBI protokolü ile GSPECT ve ERVG görüntülemeleri yapılan 48 hasta geriye dönük olarak incelendi. GSPECT Myometrix yazılımı ile SVEF, Cedars-Sinai Quantitatif Gated SPECT (QGS) analiz programı ile duvar hareket ve kalınlık skorları belirlendi. ERVG görüntülemesinde sol ön oblik görüntüleri kullanılarak SVEF değerleri hesaplandı. GSPECT ve ERVG görüntülerinde; SV duvar hareketleri görsel olarak değerlendirilerek skorlandı. Olguların EKO ile belirlenen SVEF değerleri ve duvar hareket bilgileri ile karşılaştırıldı. Bulgular: Olguların GSPECT ile hesaplanan ortalama SVEF ile ERVG verileri arasında iyi derecede korelasyon bulundu. EKO ile ölçülen nümerik SVEF değeri olan 30 olgunun; GSPECT ve EKO ile hesaplanan SVEF değerleri arasında belirgin fark olmadığı görüldü. Kırk sekiz hastadan elde edilen 240 segment incelendiğinde, görsel duvar hareketleri açısından GSPECT ile ERVG arasında %77.5 segmentte, GSPECT ile EKO arasında %75.4 segmentte uyum saptandı. Görsel olarak normokinetik segmentlerde hesaplanan hareket ve kalınlık skorları, kontraksiyon kusuru izlenen segmentlere oranla belirgin yüksek bulundu. Sonuç: GSPECTin SV fonksiyonlarının değerlendirilmesi amacıyla klinik pratikte güvenle kullanılabileceği, kantitatif olarak hesaplanan duvar hareket ve kalınlık skorlarının görsel değerlendirmeyi desteklediği düşünülmektedir.

Abstract

Objectives: In this study, we investigated the reliability of gated myocardial perfusion single-photon emission comput- erized tomography (GSPECT) for the evaluation of left ven- ricle (LV) function. We compared left ventricle ejection frac- on (LVEF) calculated with GSPECT with the values derived rom planar equilibrium-gated radionuclide ventriculography ERVG) and echocardiography (ECHO). Study design: Forty-eight patients with suspected coronary artery disease (CAD), who were referred for evaluation of myocardial perfusion and LV function and underwent two-day 99mTc-MIBI protocol GSPECT and ERVG, were examined etrospectively. LVEF was calculated with GSPECT Myome- rix software, and wall motion and thickness were calculated with QGS analysis program. In the ERVG study, LVEF val- ues were calculated using left anterior oblique images. In the GSPECT and ERVG study, wall motion was evaluated visu- ally and scored. LVEF values and wall motion data measured with ECHO were noted. Results: For all cases, there was a significant correlation between LVEF values calculated by GSPECT and ERVG. Numerical LVEF values of 30 patients measured with ECHO howed no significant difference from the values measured with GSPECT. When 240 segments obtained from 48 patients were examined, the correlation between GSPECT and ERVG was 77.5% and between GSPECT and ECHO was 75.4% by visual wall motion analysis. Quantitatively calculated wall motion and thickness scores of segments visually defined as normokinetic were significantly higher than segments visually defined as having contraction defect. Conclusion: GSPECT can be used safely in clinical practice or the evaluation of LV function. Quantitatively calculated wall motion and thickness scores are promising methods to verify he visual evaluation.

🔖

Bu Makaleye Atıf Yap

ÖMÜR, Ö., BURAK, Z., HATİPOĞLU, F. (2022). Comparison of gated myocardial perfusion SPECT, echocardiography and equilibrium radionuclide ventriculography in the evaluation of left ventricle contractility. Türk Kardiyoloji Derneği Arşivi, Cilt: 42 - Sayı: 4, 349–357. https://ajindex.com/articles/632759

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Bellenger NG, Marcus NJ, Davies C, Yacoub M, Banner NR, Pennell DJ. Left ventricular function and mass after orthotopic heart transplantation: a comparison of cardiovascular magnetic resonance with echocardiography. J Heart Lung Transplant 2000
  2. CrossRef 2. Teichholz LE, Kreulen T, Herman MV, Gorlin R. Problems in echocardiographic volume determinations: echocardiographic- angiographic correlations in the presence of absence of asynergy. Am J Cardiol 1976
  3. CrossRef 3. Feigenbaum H, Armstrong WF, Ryan T. Feigenbaum’s echcardiography. 6th ed. Philadelphia: Lippincoot Williams and Wilkins
  4. p. 138-79. 4. Whalley GA, Gamble GD, Walsh HJ, Sharpe N, Doughty RN. Quantitative evaluation of regional endocardial visualisation with second harmonic imaging and contrast left ventricular opacification in heart failure patients. Eur J Echocardiogr 2005
  5. CrossRef 5. Pandian NG. Clinical applications of contrast echocardiography. Eur J Echocardiogr 2004
  6. 5 Suppl 2:S3-10. CrossRef 6. Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/ AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation 2003
  7. CrossRef 7. Bacher-Stier C, Müller S, Pachinger O, Strolz S, Erler H, Moncayo R, et al. Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography. Eur J Nucl Med 1999
  8. CrossRef 8. Patel CD, Nadig MR, Kurien S, Barai S, Narang R, Malhotra A. Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography. Nucl Med Commun 2006
  9. CrossRef 9. Anagnostopoulos C, Henein MY, Underwood SR. Non-invasive investigations. Br Med Bull 2001
  10. CrossRef 10. Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, et al. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1995
  11. CrossRef 11. Sharir T, Germano G, Kang X, Le