Dergiler / Turkish Journal of Veterinary and Animal Sciences / 2017 / Cilt: 41 - Sayı: 5

Efficacy of repeatedly used CIDR device in cattle reproduction: a metaanalysisreview of progesterone concentration and conception rate

Sayfa
692–697
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In summary, depending upon the initial P4 load (1.38 1.90 g), the CIDR device could be used twice in lactating cows and four times in heifers after autoclaving to achieve target blood P4 concentrations.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In order to reduce estrus synchronization cost, utilization of residual progesterone (P4) in the used controlled internal drug release (CIDR) device upon sanitization can be possible.
📊
Temel Bulgular & Veri:Two datasets were compiled from 8 and 7 research articles involving 3434 (2653 heifers + 771 lactating cows + 10 ovariectomized cows) and 7301 cattle (3879 heifers + 3422 lactating cows) to evaluate blood P4 concentration and conception rate, respectively, in response to repeatedly used CIDR devices after sanitization via autoclaving and disinfection.
💡
Sonuç & Katkı:In summary, depending upon the initial P4 load (1.38 1.90 g), the CIDR device could be used twice in lactating cows and four times in heifers after autoclaving to achieve target blood P4 concentrations.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

In order to reduce estrus synchronization cost, utilization of residual progesterone (P4) in the used controlled internal drug release (CIDR) device upon sanitization can be possible. Two datasets were compiled from 8 and 7 research articles involving 3434 (2653 heifers + 771 lactating cows + 10 ovariectomized cows) and 7301 cattle (3879 heifers + 3422 lactating cows) to evaluate blood P4 concentration and conception rate, respectively, in response to repeatedly used CIDR devices after sanitization via autoclaving and disinfection. As the number of CIDR usages increased, blood P4 concentration decreased linearly (y =0.484X + 3.135, R2 = 0.99,P < 0.001). Blood P4 concentration (1.52 vs. 2.20 ng/mL; P < 0.002) and conception rate (40.76 vs. 32.96%, P < 0.05) for lactating cows were lower than those for heifers. The sanitization method did not affect blood P4 concentration, but reused CIDR device subjected to disinfection was associated with reduced conception rate. In summary, depending upon the initial P4 load (1.38 1.90 g), the CIDR device could be used twice in lactating cows and four times in heifers after autoclaving to achieve target blood P4 concentrations.

🔖

Bu Makaleye Atıf Yap

ÇOLAK, A., HAYIRLI, A., CHACHER, M. F. A. (2022). Efficacy of repeatedly used CIDR device in cattle reproduction: a metaanalysisreview of progesterone concentration and conception rate. Turkish Journal of Veterinary and Animal Sciences, Cilt: 41 - Sayı: 5, 692–697. https://ajindex.com/articles/615030

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Stevenson JS. Synchronization of estrus and ovulation in dairy cows. Adv Dairy Technol 2001
  2. Colazo MG, Mapletoft RJ. A review of current timed-AI (TAI) programs for beef and dairy cattle. Can Vet J 2014
  3. Wiltbank MC, Souza AH, Giordano JO, Nascimento AB, Vasconcelos JM, Pereira MHC, Fricke PM, Surjus RS, Zinsly FCS, Carvalho PD et al. Positive and negative effects of progesterone during timed AI protocols in lactating dairy cattle. Anim Reprod 2012
  4. Islam R. Synchronization of estrus in cattle: a review. Veterinary World 2011
  5. Zuluaga JF, Williams GL. High-pressure steam sterilization of previously used CIDR inserts enhances the magnitude of the acute increase in circulating progesterone after insertion in cows. Anim Reprod Sci 2008
  6. Van Werven T, Waldeck F, Souza AH, Floch S, Englebienne M. Comparison of two intravaginal progesterone releasing devices (PRID-Delta vs CIDR) in dairy cows: blood P4 profile and field fertility. Anim Reprod Sci 2013
  7. Rathbone MJ, Bunt CR, Ogle CR, Burggraaf S, Macmillan KL, Burke CR, Pickering KL. Reengineering of a commercially available bovine intravaginal insert (CIDR insert) containing P4. J Control Release 2002
  8. Cerri RLA, Rutigliano HM, Bruno RGS, Santos JEP. Progesterone concentration, follicular development and induction of cyclicity in dairy cows receiving intravaginal progesterone inserts. Anim Reprod Sci 2009
  9. Brann DW, Chorich LP, Mahesh VB. Effect of progesterone on galanin mRNA levels in the hypothalamus and the pituitary: correlation with the gonadotropin surge. Neuroendocrinology 1993
  10. Kasimanickam R, Day ML, Rudolph JS, Hall JB, Whittier WD. Two doses of prostaglandin improve pregnancy rates to timed-AI in a 5-day progesterone-based synchronization protocol in beef cows. Theriogenology 2009
  11. Peres RFG, Júnior IC, Sá Filho OG, Nogueira GDP, Vasconcelos JLM. Strategies to improve fertility in Bos indicus postpubertal heifers and nonlactating cows submitted to fixed-time artificial insemination. Theriogenology 2009
  12. Macmillan KL, Taufa VK, Barnes DR, Day AM. Plasma progesterone concentrations in heifers and cows treated with a new intravaginal device. Anim Reprod Sci 1991
  13. Perry GA, Grant JK, Walker JA, Bridges GA, Kruse SG, Bird S, Heaton K, Arias R, Lake SL. Comparison of Three CIDR-Based Fixed-Time AI Protocols for Beef