Dergiler / Turkish Journal of Medical Sciences / 2020 / Cilt: 50 - Sayı: 5

A novel urethra compression technique using Turkish continence device for male urinary incontinence

Sayfa
1210–1216
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Additionally, the technique for implanting the device is very simple and would likely be learned quickly.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: The male sling operation and artificial urinary sphincter implantation are common methods for treating urinary incontinence.
📊
Temel Bulgular & Veri:Results: The balloon volume for efficient urethral closure pressure using the new device was under 1 mL.
💡
Sonuç & Katkı:Additionally, the technique for implanting the device is very simple and would likely be learned quickly.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Background/aim: The male sling operation and artificial urinary sphincter implantation are common methods for treating urinary incontinence. However, there are some drawbacks to these methods such as infection, urethral erosion, pain, inefficiency, and the technical difficulty of the operations. Here we describe a new device we have named the Turkish Continence Device (TCD) which has advantages over these other methods. The aim of this study was perform experiments with the TCD prototype in vivo and ex vivo to determine efficiency, convenience of implantation, and negative effects. Materials and methods: We implanted the prototype device in male goats and sheep, compressing the posterior urethra, and then fixed it by sutures on the lateral sides of the cavernosal bodies, bilaterally. Then we recorded urodynamic findings and performed urinary imaging. Additionally we measured urethral closure pressure ex vivo. Results: The balloon volume for efficient urethral closure pressure using the new device was under 1 mL. It compressed the urethra towards the corpus cavernosum perfectly, because the wings of the prototype device are fixed near the tunica of the cavernosal bodies on each side. Conclusion: A smaller device with smaller arms/wings would be efficient for obtaining enough pressure on the urethra. Additionally, the technique for implanting the device is very simple and would likely be learned quickly.

🔖

Bu Makaleye Atıf Yap

SANCAK, İ. G., MAHMUT, Z., ÖLÇÜCÜOĞLU, E., TAŞTEMUR, S., KASAP, Y., ZENGİN, N., ODABAŞ, Ö. (2022). A novel urethra compression technique using Turkish continence device for male urinary incontinence. Turkish Journal of Medical Sciences, Cilt: 50 - Sayı: 5, 1210–1216. https://ajindex.com/articles/610051

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Rodriguez E, Skarecky DW, Ahlering TE. Post-robotic prostatectomy urinary continence: Characterization of perfect continence versus occasional dribbling in pad-free man. Urology 2006; 67: 785-788
  2. Hu JC, Elkin EP, Pasta DJ, Lubeck DP, Kattan MW et al. Predicting quality of life after radical prostatectomy: Results from CaPSURE. Journal of Urolology 2004; 171:703-707
  3. Olsson LE, Salomon L, Nadu A, Hoznek A, Cicco A et al. Prospective patient-reported continence after laparoscopic radical prostatectomy. Urology 2001; 58: 570-572
  4. Schröder A, Abrams P, Andersson KE. Guidelines on urinary incontinence. In: Arnheim, AG (editor). EUA Guidilines. Arnheim, Netherlands: European Association of Urology; 2010. pp. 11-28
  5. Scott FB, Bradley WE, Timm GW. Treatment of urinary incontinence by implantable prosthetic sphincter. Urology 1973; 1(3): 252-259
  6. Montague DK. Evolution of implanted devices for urinary incontinence. Cleveland Clinic Quarterly 1984; 51 (2): 405-409
  7. Brito CG, Mulcahy JJ, Mitchell ME, Adams MC. Use of a double cuff AMS800 urinary sphincter for severe stress incontinence. Journal of Urology 1993; 149 (2): 283-285
  8. O’Connor RC, Lyon MB, Guralnick ML, Bales GT. Long-term follow- up of single versus double cuff artificial urinary sphincter insertion for the treatment of severe postprostatectomy stress urinary incontinence. Urology 2008; 71 (1): 90-93
  9. Guralnick ML, Miller E, Toh KL, Webster GD. Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy. Journal of Urology 2002; 167 (5): 2075-2078
  10. Wiedemann L, Cornu JN, Haab E, Peyrat L, Beley S et al. Transcorporal artificial urinary sphincter implantation as a salvage surgical procedure for challenging cases of male stress urinary incontinence: surgical technique and functional outcomes in a contemporary series. British Journal of Urology International 2013; 112 (8): 1163-1168
  11. Aaronson DS, Elliott SP, McAninch JW. Transcorporal artificial urinary sphincter placement for incontinence in high-risk patients after treatment of prostate cancer. Urology 2008; 72 (4): 825-827
  12. Magera JS, Elliott DS. Tandem transcorporal artificial urinary sphincter cuff salvage technique: surgical description and results. Journal of Urology 2007; 177 (3): 1015-1019
  13. Craggs MD, Chaffey NJ, Mundyt AR. A preliminary report on a new hydraulic sphincter for controlling urinary incontinence. Journal of Medical Engineering and Tec