Dergiler / Turkish Journal of Medical Sciences / 2020 / Cilt: 50 - Sayı: 1

Evaluation of a two-image technique consisting of an axial and a coronal image generated by using the rib-flattening application: effect on reading time and diagnostic validity

Sayfa
59–65
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Reading times, validity indices, and agreement levels with reference data were evaluated for both readers.Results: The median reading time of the junior examiner significantly decreased with the rib-flattening method (160.5 s vs. 70.0 s; P

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background/aim: When reading a chest CT, a radiologist needs to evaluate each rib one by one due to complex curvy shape, whichmakes reporting a tiresome and time-consuming task.
📊
Temel Bulgular & Veri:This study aimed to evaluate the effect of a two-image set created by using the rib-flatteningapplication on the performance of a radiologist in detecting sclerotic rib lesions in cancer patients.Materials and methods: The local Institutional Review Board approved this retrospective study.
💡
Sonuç & Katkı:Reading times, validity indices, and agreement levels with reference data were evaluated for both readers.Results: The median reading time of the junior examiner significantly decreased with the rib-flattening method (160.5 s vs. 70.0 s; P
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Background/aim: When reading a chest CT, a radiologist needs to evaluate each rib one by one due to complex curvy shape, whichmakes reporting a tiresome and time-consuming task. A new curved planar reformat application that flattens ribs on a single plane mayfind a place in the radiology reporting room. This study aimed to evaluate the effect of a two-image set created by using the rib-flatteningapplication on the performance of a radiologist in detecting sclerotic rib lesions in cancer patients.Materials and methods: The local Institutional Review Board approved this retrospective study. Two radiologists with differentexperience levels reviewed chest CT examinations of 106 patients (76 men, 30 women). We divided the patients into group A (n =54), reviewed by a standard method, and group B (n = 52), reviewed by a standard method and the two-image set created on the ribflatteningapplication. Reading times, validity indices, and agreement levels with reference data were evaluated for both readers.Results: The median reading time of the junior examiner significantly decreased with the rib-flattening method (160.5 s vs. 70.0 s; P

🔖

Bu Makaleye Atıf Yap

KILIÇ, K., ERDOĞAN, N., ARAÇ, M., AKYÜZ, M., ERBAŞ, G., CİNDİL, E. (2022). Evaluation of a two-image technique consisting of an axial and a coronal image generated by using the rib-flattening application: effect on reading time and diagnostic validity. Turkish Journal of Medical Sciences, Cilt: 50 - Sayı: 1, 59–65. https://ajindex.com/articles/609813

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Levine BD, Motamedi K, Chow K, Gold RH, Seeger LL. CT of rib lesions. AJR American Journal of Roentgenology 2009
  2. 193 (1): 5-13. doi: 10.2214/ajr.08.1216 2. Macedo F, Ladeira K, Pinho F, Saraiva N, Bonito N et al. Bone metastases: An overview. Oncology Reviews 2017
  3. 11 (1): 321. doi: 10.4081/oncol.2017.321 3. Tateishi U, Gladish GW, Kusumoto M, Hasegawa T, Yokoyama R et al. Chest wall tumors: radiologic findings and pathologic correlation: part 2. Malignant tumors. Radiographics 2003
  4. 23 (6): 1491-1508. doi: 10.1148/rg.236015527 4. Guttentag AR, Salwen JK. Keep your eyes on the ribs: the spectrum of normal variants and diseases that involve the ribs. Radiographics 1999
  5. 19 (5): 1125-1142. doi: 10.1148/ radiographics.19.5.g99se011125 5. Cho SH, Sung YM, Kim MS. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT. British Journal of Radiology 2012
  6. 85 (1018): e845-850. doi: 10.1259/bjr/28575455 6. Alkadhi H, Wildermuth S, Marincek B, Boehm T. Accuracy and time efficiency for the detection of thoracic cage fractures: volume rendering compared with transverse computed tomography images. Journal of Computer Assisted Tomography 2004
  7. 28 (3): 378-385. doi: 10.1097/00004728- 200405000-00013 7. Ringl H, Lazar M, Topker M, Woitek R, Prosch H et al. The ribs unfolded – a CT visualization algorithm for fast detection of rib fractures: effect on sensitivity and specificity in trauma patients. European Radiology 2015
  8. 25 (7): 1865-1874. doi: 10.1007/s00330-015-3598-2 8. Ha JY, Jeon KN, Bae K, Choi BH. Effect of bone reading CT software on radiologist performance in detecting bone metastases from breast cancer. British Journal of Radiology 2017
  9. 90 (1072): 20160809. doi: 10.1259/bjr.20160809 9. Homann G, Weisel K, Mustafa DF, Ditt H, Nikolaou K et al. Improvement of diagnostic confidence for detection of multiple myeloma involvement of the ribs by a new CT software generating rib unfolded images: Comparison with 5- and 1-mm axial images. Skeletal Radiology 2015
  10. 44 (7): 971- 979. doi: 10.1007/s00256-015-2131-7 10. Seuss H, Dankerl P, Cavallaro A, Uder M, Hammon M. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images. BMC Medical Imaging 2016
  11. 16 (1): 39. doi: 10.1186/s12880-016- 0141-0 11. Watson PF, Petrie A. Method agreement analysis: a review of correct methodology. Therioge