Dislodged Watchman Device Retrieved Using Double Transseptal Sheaths Technique and Reinstalled with LAmbre Device

Sayfa
407–410
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
🔖

Bu Makaleye Atıf Yap

HAN, Y., WANG, F., XIAOKERETI, J., YANG, H., LU, Y., ZHOU, X., LI, Y., TANG, B. (2022). Dislodged Watchman Device Retrieved Using Double Transseptal Sheaths Technique and Reinstalled with LAmbre Device. The Anatolian Journal of Cardiology, Cilt: 26 - Sayı: 5, 407–410. https://ajindex.com/articles/597231

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Chen S, Chun KRJ, Bordignon S, et al. Left atrial appendage occlusion using LAmbre Amulet and Watchman in atrial fibrillation. J Cardiol. 2019
  2. 73(4):299-306. [CrossRef] 2. Chinese Society of Cardiology of Chinese Medical, A. and C. Editorial Board of Chinese Journal of. 2019 Chinese Society of Cardiology (CSC) expert consensus statement on left atrial appendage closure in the prevention of stroke in patients with atrial fibrillation. Zhonghua Xin Xue Guan Bing Za Zhi. 2019
  3. 47(12):937-955. 3. Spronk HM, De Jong AM, Verheule S, et al. Hypercoagulability causes atrial fibrosis and promotes atrial fibrillation. Eur Heart J. 2017
  4. 38(1):38-50. [CrossRef] 4. January CT, Wann LS, Calkins H, et al. 2019 AHA/ACC/HRS focused update of the 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice guidelines and the Heart Rhythm Society in collaboration with the Society of Thoracic Surgeons. Circulation. 2019
  5. 140(2):e125-e151. [CrossRef] 5. Wang ZZ, Du X, Wang W, et al. Long-term persistence of newly initiated warfarin therapy in Chinese patients with nonvalvular atrial fibrillation. Circ Cardiovasc Qual Outcomes. 2016
  6. 9(4): 380-387. [CrossRef] 6. Holmes DR, Jr, Reddy VY, Gordon NT, et al. Long-term safety and efficacy in continued access left atrial appendage closure registries. J Am Coll Cardiol. 2019
  7. 74(23):2878-2889. [CrossRef] 7. Boersma LV, Schmidt B, Betts TR, et al. Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry. Eur Heart J. 2016
  8. 37(31):2465-2474. [CrossRef] 8. So CY, Lam YY, Cheung GS, et al. Occlusion of a multilobed shallow left atrial appendage using a special LAmbre device after failed watchman implantation. J Invasive Cardiol. 2019
  9. 31(2):E41-E42. 9. Huang H, Liu Y, Xu Y, et al. Percutaneous left atrial appendage closure with the LAmbre device for stroke prevention in atrial fibrillation: a prospective, multicenter clinical study. JACC Cardiovasc Interv. 2017
  10. 10(21):2188-2194. [CrossRef] 10. Boersma LV, Ince H, Kische S, et al. Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-year followup outcome data of the EWOLUTION trial. Heart Rhythm. 2017
  11. 14(9):1302-1308. [CrossRef] 11. Turagam MK, Neuzil P, Dukkipati SR, et al. Percutaneous retrieval of