Dergiler / Retina-Vitreus / 2021 / Cilt: 30 - Sayı: 3

Refractive Results After Combined Cataract-pars Plana Vitrectomy Surgery in Patients with Maculaoff Rhegmatogenous Retinal Detachment in Whom the Intraocular Lens is Implanted Using the Biometric Measurements of the Healthy Eye

Sayfa
253–256
Yayın Tarihi
2022-10-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: Biometric values of the healthy eye can be used for IOL implantation in the presence of a cataract with macula-off retinal detachment.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: Cataract with macula-off retinal detachment may prevent the surgical field.
📊
Temel Bulgular & Veri:Therefore, it will not be possible to obtain an accurate biometry Different methods are used for accurate measurement in the affected eye.
💡
Sonuç & Katkı:Conclusion: Biometric values of the healthy eye can be used for IOL implantation in the presence of a cataract with macula-off retinal detachment.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Purpose: Cataract with macula-off retinal detachment may prevent the surgical field. Combined surgery may be required. It is difficult to measure axial length in cases involving the macula. Therefore, it will not be possible to obtain an accurate biometry Different methods are used for accurate measurement in the affected eye. We wanted to show the results of cases in which biometric measurements were of the healthy eye, which is an alternative method, were used. Materials and methods: Thirty- two patients who had underwent combined phacoemulsification pars plana vitrectomy silicone injection surgery was included in the study. The healthy eye biometrics were used for intraocular lens power selection. Refraction results were obtained after silicone oil removal. Mann-Whitney U test was used to compare the expected refraction values in healthy eye measurements and the resulting refraction values of the operated eye. Results: There was a significant increase in visual acuity after surgery (1.2 ± 0.48 logMar, 0.6 ± 0.41, p = 0.001, p 0.05). There was no significant difference between the expected refraction value of the healthy eye and the result refraction value of the operated eye (p = 0.35, p> 0.05). Conclusion: Biometric values of the healthy eye can be used for IOL implantation in the presence of a cataract with macula-off retinal detachment.

🔖

Bu Makaleye Atıf Yap

BAYBORA, H. (2022). Refractive Results After Combined Cataract-pars Plana Vitrectomy Surgery in Patients with Maculaoff Rhegmatogenous Retinal Detachment in Whom the Intraocular Lens is Implanted Using the Biometric Measurements of the Healthy Eye. Retina-Vitreus, Cilt: 30 - Sayı: 3, 253–256. https://ajindex.com/articles/589058

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Caiado RR, Magalhaes O, Jr, Badaro E, et al. Effect of lens status in the surgical success of 23gauge primary vitrectomy for the management of rhegmatogenous retinal detachment: The Pan American Collaborative Retina Study (PACORES) group results. Retina 2015; 35: 326-33
  2. Hamoudi H, La Cour M. Refractive changes after vitrectomy and phacovitrectomy for macular hole and epiretinal membrane. J Cataract Refract Surg 2013; 39: 942-47
  3. Heiligenhaus A, Holtkamp A, Koch J, et al. Combined phacoemulsification and pars plana vitrectomy: clear corneal versus scleral incisions; prospective randomized multicenter study. J Cataract Refract Surg 2003; 29: 1106-12
  4. Treumer F, Bunse A, Rudolf M, et al J. Pars plana vitrectomy, phacoemulsification and intraocular lens implantation. Comparison of clinical complications in a combined versus two- step surgical approach. Graefes Arch Clin Exp Ophthalmol 2006; 244:808-15
  5. Etuş H, Karabaş L, Altıntaş Ö, ve arkadaşları. Proliferatif diyabetik retinopatili olgularda kombine fako-pars plana vitrektomi cerrahisi sonuçlarımız. Retina-Vitreus 2006; 14: 269- 74 6. Boulter T, Bernhiesel A, Mammalis C, et al. Phacoemulsificationin review: Optimisation of cataract removal in an in-vitro setting. Survey Ophthalmol 2015; 68: 868-75
  6. Seyhan SO, Citirik M, Beyazyildiz E, et al. 23gauge vitrectomy and silicone oil tamponade with and without phacoemulsification in rhegmatogenous retinal detachment. Int J Clin Exp Med. 2015; 8:4257-62
  7. Savastano A, Savastano MC, Barca F, et all. Combining cataract surgery with 25-gauge high-speed pars plana vitrectomy:Result from a retrospective study. Ophthalmology 2014; 121:299-04
  8. Chung TY, Chung H, Lee JH. Combined surgery and sequential comprising Phacoemulsification- pars plana vitrectomy, and intraocular lens implantation: comparison of clinical outcomes. J Cataract Refract Surg 2002; 28:2001-5
  9. Olsen T. Calculation of intraocular lens power: a review Acta Ophthalmol Scand 2007; 85:472-85
  10. Cho KH, Park IW, Kwon SI. Changes in postoperative refractive outcomes following combined phacoemulsification and pars plana vitrectomy for rhegmatogenous retinal detachment. Am J Ophthalmol 2014; 158: 251-6
  11. Jeoung JW, Chung H, Yu HG. Factors influencing refractive outcomes after combined pars plana vitrectomy: Results of a prospective study. J Cataract Refract Surg 2007; 33;108-14
  12. Huang C, Zhang T, Liu J, et al. Changes in axial length, central cornea thickness, and anterior cha