Dergiler / Retina-Vitreus / 2021 / Cilt: 30 - Sayı: 2

Evaluating the Refraction Results of Patients who had Combined Phacoemulsification-pars Plana Vitrectomy and Internal Limiting Membrane Peeling for Idiopathic Macular hole or Idiopathic Epiretinal Membrane

Sayfa
163–166
Yayın Tarihi
2022-10-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Results: There was no significant difference between the combined surgery group and the control group refraction results (p = 0.41, p> 0.05) and also between expected refraction and final refraction in the surgery group (p = 0.16, p> 0.05).

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: Although cataracts can be seen after pars plana vitrectomy, also be seen with vitreomacular interface pathologies such as a mac ular hole and epiretinal membrane.
📊
Temel Bulgular & Veri:Also, we wanted to find any difference between expected and final refraction in our study group Materials and methods: Retrospective combined phacoemulsification - Pars plana vitrectomy-internal limiting membrane peeling 33 macular holes and 10 epiretinal membrane patients and 43 control patients with the only phacoemulsification were included in the study.
💡
Sonuç & Katkı:Results: There was no significant difference between the combined surgery group and the control group refraction results (p = 0.41, p> 0.05) and also between expected refraction and final refraction in the surgery group (p = 0.16, p> 0.05).
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Purpose: Although cataracts can be seen after pars plana vitrectomy, also be seen with vitreomacular interface pathologies such as a mac ular hole and epiretinal membrane. Since this may cause difficulties in imaging the surgical field, cataract surgery combined with surgery for primary pathology may be required. With the development of small incision microsurgical techniques and more precise biometric measurements, results close to emmetropic can be obtained today. Since internal limiting membrane peeling is performed together in hole and ERM surgery, we planned this study to investigate whether there is a signi ficant difference between the final refraction and the refraction of noncomplicated phacoemusification performed control group. Also, we wanted to find any difference between expected and final refraction in our study group Materials and methods: Retrospective combined phacoemulsification - Pars plana vitrectomy-internal limiting membrane peeling 33 macular holes and 10 epiretinal membrane patients and 43 control patients with the only phacoemulsification were included in the study. Intraocular lens power to be implanted was measured by low coherence interferometry. Comparison of expected postoperative refraction with result refraction Wilcoxon test and comparison with the control group was performed with the Mann-Whitney U test. Results: There was no significant difference between the combined surgery group and the control group refraction results (p = 0.41, p> 0.05) and also between expected refraction and final refraction in the surgery group (p = 0.16, p> 0.05).

🔖

Bu Makaleye Atıf Yap

BAYBORA, H. (2022). Evaluating the Refraction Results of Patients who had Combined Phacoemulsification-pars Plana Vitrectomy and Internal Limiting Membrane Peeling for Idiopathic Macular hole or Idiopathic Epiretinal Membrane. Retina-Vitreus, Cilt: 30 - Sayı: 2, 163–166. https://ajindex.com/articles/589053

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Kelly NE, Wendel RT. Vitreous surgery for idiopathic macular holes: Results of a pilot Study. Arch Ophthalmol 1991;109:654-9
  2. Pated D, Rahman R, Kumarasamy M. Accuracy of intraocular power estimation in eyes Having phacovitrectomy for macular holes. J Cataract Refract Surg 2007; 33: 1760-62
  3. Sousha MA, Yoo SH. Cataract surgery after parsplana vitrectomy. Curr Opin Ophthalmol 2010; 21: 45-9
  4. Caiado RR, Magalhaes O, Jr, Badaro E,et al. Effect of lens status in the surgical success of 23-gaugae primary vitrectomy for the management of rhegmatogenous retinal detachment: The Pan American Collaborative Retina Study (PACORES) group results. Retina 2015; 35: 326-33
  5. Boulter T, Bernhiesel A, Mammalis C, Zaugg B, Barlow WR, Olson RJ, Pettey JH. Phaco emulsification review: Optimisation of cataract removal in an in-vitro setting. Survey 6. Nanvikar SR,Allen D, Steel D.H.W. Optical bioemtry in combined phacovitrectomy. J Cataract Refract Surg 2009; 35: 64-69
  6. Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan Ultrasound biometry for intraocular lens calculation. Clin Exp Ophthalmol 2003; 31: 12-124
  7. Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 1992; 18: 125-9
  8. Kriechbaum K, Sacu S, Kiss B, et al. In fluence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery. J Cataract Refract Surg 2003; 29: 1950-55
  9. Findl O, Drexler W, Menapace R, Heinzl H, Hitzenberger CK, Fercher AF. Improved prediction of intraocular lens power using partial coherence interferometry. J Cataract Refract Surg 2001; 27: 861-7
  10. Olsen T. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster. Acta Ophthalmol Scand 2007; 85:84-7
  11. Olsen T. Calculation of intraocular lens power: a rewiev. Acta Ophthalmol Scand 2007;85: 472-85
  12. Akinci A, Batman C, Zilelioğlu O. Cataract surgery in previously vitrectomized eyes. In J Clin Pract 2008; 62: 770-5
  13. Mc Dermott ML, Puklin JE, Abrams GW,Eliott D. Phacoemulsification for cataract following pars plana vitrectomy. Ophthalmic Surg Lasers 1997; 28:558-64
  14. Falkner- Radler CI, Benesch T, Binder S. Accuracy of preoperative biometry in vitrectomy combined with cataract surgery for patients with epirretinal membranes and macular holes; result of a postoperative controlled clinical trial. J Cataract Refract Surg 2008;34: 1754-60
  15. Patel D, Rahman R, Kumarasamy M