Dergiler / Retina-Vitreus / 2022 / Cilt: 31 - Sayı: 1

Correlations of Optic Disc Morphological Parameters with Peripapillary Choroidal Thickness and Retinal Vessel Caliber Measurements

Sayfa
44–49
Yayın Tarihi
2022-10-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusions: Optic disc maximum contour elevation is positively correlated with the peripapillary choroidal thickness and negatively correlated with the RNFL thickness in the healthy eyes.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: To examine the associations between the optic disc morphological parameters, peripapillary choroidal thickness, and retinal vessel caliber measurements.
📊
Temel Bulgular & Veri:Methods: This cross-sectional and descriptive study included 60 eyes of 60 healthy adults.
💡
Sonuç & Katkı:Conclusions: Optic disc maximum contour elevation is positively correlated with the peripapillary choroidal thickness and negatively correlated with the RNFL thickness in the healthy eyes.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Purpose: To examine the associations between the optic disc morphological parameters, peripapillary choroidal thickness, and retinal vessel caliber measurements. Methods: This cross-sectional and descriptive study included 60 eyes of 60 healthy adults. The spectral domain optical coherence tomography was used to measure the retinal arteriolar caliber, retinal venular caliber, peripapillary choroidal thickness, and retinal nerve fiber layer (RNFL) thickness. Optic disc morphological parameters were measured via Heidelberg Retinal Tomography 3. Results: The retinal arteriolar caliber was statistically significantly positively correlated with the rim volume (r = 0.27, P = 0.035) and RNFL cross-sectional area (r = 0.30, P = 0.02); but it was not associated with the other optic disc parameters (P > 0.05). The retinal venular caliber was not correlated with the optic disc parameters (P > 0.05). The peripapillary choroidal thickness was statistically significantly correlated only with the cup shape measurement (r = -0.27, P = 0.039), maximum contour elevation (r = 0.50, P < 0.001), and maximum contour depression (r = 0.28, P = 0.033). The RNFL thickness was statistically significantly positively correlated only with the disc area (r = 0.30, P = 0.019) and rim volume (r = 0.27, P = 0.039), and negatively correlated with the maximum contour elevation (r = -0.32, P = 0.012). Conclusions: Optic disc maximum contour elevation is positively correlated with the peripapillary choroidal thickness and negatively correlated with the RNFL thickness in the healthy eyes.

🔖

Bu Makaleye Atıf Yap

Pekel, G., Ongun, G. T., Pekel, E., Parç, O., Demirtaş, Ö., Ün, E. Ş., Çetin, E. N. (2022). Correlations of Optic Disc Morphological Parameters with Peripapillary Choroidal Thickness and Retinal Vessel Caliber Measurements. Retina-Vitreus, Cilt: 31 - Sayı: 1, 44–49. https://ajindex.com/articles/589031

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Rohrschneider K, Burk RO, Kruse FE, et al. Reproducibility of the optic nerve head topography with a new laser tomographic scanning device. Ophthalmology. 1994;101:1044-9
  2. Mikelberg FS, Parfitt CM, Swindale NV, et al. Ability of the heidelberg retina tomograph to detect early glaucomatous visual field loss. J Glaucoma. 1995;4:242-7
  3. Iester M, Mikelberg FS, Drance SM. The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph. Ophthalmology. 1997;104:545-8
  4. Murthy RK, Haji S, Sambhav K, et al. Clinical applications of spectral domain optical coherence tomography in retinal diseases. Biomed J. 2016;39:107-20
  5. Adhi M, Duker JS. Optical coherence tomography--current and future applications. Curr Opin Ophthalmol. 2013;24:213-21
  6. Gupta P, Cheung CY, Baskaran M, et al. Relationship Between Peripapillary Choroid and Retinal Nerve Fiber Layer Thickness in a Population-Based Sample of Nonglaucomatous Eyes. Am J Ophthalmol. 2016;161:4-11.e1-2
  7. Sigler EJ, Mascarenhas KG, Tsai JC, et al. Clinicopathologic correlation of disc and peripapillary region using SD-OCT. Optom Vis Sci. 2013;90:84-93
  8. Lam J, Chan G, Morgan WH, et al. Structural characteristics of the optic nerve head influencing human retinal venous pulsations. Exp Eye Res. 2016;145:341-346
  9. Yabana T, Shiga Y, Kawasaki R, et al. Evaluating retinal vessel diameter with optical coherence tomography in normal-tension glaucoma patients. Jpn J Ophthalmol. 2017;61:378-387
  10. Pereira I, Weber S, Holzer S, et al. Compensation for retinal vessel density reduces the variation of circumpapillary RNFL in healthy subjects. PLoS One. 2015;10:e0120378
  11. Yamashita T, Sakamoto T, Yoshihara N, et al. Correlations between local peripapillary choroidal thickness and axial length, optic disc tilt, and papillo-macular position in young healthy eyes. PLoS One. 2017;12:e0186453
  12. Okimoto S, Yamashita K, Shibata T, et al. Morphological features and important parameters of large optic discs for diagnosing glaucoma. PLoS One. 2015;10:e0118920
  13. Tham YC, Siantar RG, Cheung CY, et al. Inter-Relationships Between Retinal Vascular Caliber, Retinal Nerve Fiber Layer Thickness, and Glaucoma: A Mediation Analysis Approach. Invest Ophthalmol Vis Sci. 2016;57:3803-9
  14. Russo A, Costagliola C, Rizzoni D, et al. Arteriolar Diameters in Glaucomatous Eyes with Single-Hemifield Damage. Optom Vis Sci. 2016;93:504-9
  15. Tham YC, Cheng CY, Zheng Y, et al. Relationship between retina