Dergiler / Perinatal journal (Online) / 2022 / Cilt: 30 - Sayı: 2

Ultrasound in labor: clinical practice guideline recommendation by the World Association of Perinatal Medicine (WAPM) and the Perinatal Medicine Foundation (PMF)

Sayfa
103–127
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:This recommendation document follows the mission of the World Association of Perinatal Medicine (WAPM) in collaboration with the Perinatal Medicine Foundation (PMF).
📊
Temel Bulgular & Veri:We aim to bring together groups and individuals throughout the world for standardization to implement the ultrasound evaluation in labor ward and improve the clinical management of labor.
💡
Sonuç & Katkı:The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

This recommendation document follows the mission of the World Association of Perinatal Medicine (WAPM) in collaboration with the Perinatal Medicine Foundation (PMF). We aim to bring together groups and individuals throughout the world for standardization to implement the ultrasound evaluation in labor ward and improve the clinical management of labor. Ultrasound in labor can be performed using a transabdominal or a transperineal approach depending upon which parameters are being assessed. During transabdominal imaging, fetal anatomy, presentation, liquor volume, and placental localization can be determined. The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.

🔖

Bu Makaleye Atıf Yap

KAMEL, R., LEES, C., ŞEN, C., RİZZO, G., GHİ, T., HENRİCH, W., TUTSCHEK, B., KOVALENKO, M., LAU, W., EGGEBO, T. M., ACHİRON, R., MAPPA, I. (2022). Ultrasound in labor: clinical practice guideline recommendation by the World Association of Perinatal Medicine (WAPM) and the Perinatal Medicine Foundation (PMF). Perinatal journal (Online), Cilt: 30 - Sayı: 2, 103–127. https://ajindex.com/articles/588295

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Dupuis O, Ruimark S, Corrine D, Simone T, Andre D, Rene- Charles R. Fetal head position during the second stage of labor: comparison of digital and vaginal examination and transabdominal ultrasonographic examination. Eur J Obstet Gynecol Reprod Biol 2005
  2. 193–7. [PubMed] [CrossRef] 2. Akmal S, Kametas N, Tsoi E, Hargreaves C, Nicolaides KH. Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery. Ultrasound Obstet Gynecol 2003
  3. 437–40. [PubMed] [CrossRef] 3. Sherer DM, Miodovnik M, Bradley S, Langer O. Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor. Ultrasound Obstet Gynecol 2002
  4. 258–63. [PubMed] [CrossRef] 4. Sainz JA, Borrero C, Aquise A, Serrano R, Gutierrez L, Fernández-Palacín A. Utility of intrapartum transperineal ultrasound to predict cases of failure in vacuum extraction attempt and need of cesarean section to complete delivery. J Matern Fetal Neonatal Med 2016
  5. 1348–52. [PubMed] [CrossRef] 5. Kasbaoui S, Severac F, Aïssi G, Gaudineau A, Lecointre L, Akladios C, et al. Predicting the difficulty of operative vaginal delivery by ultrasound measurement of fetal head station. Am J Obstet Gynecol 2017
  6. e1–9. [PubMed] [CrossRef] 6. Usman S, Barton H, Wilhelm-Benartzi C, Lees CC. Ultrasound is better tolerated than vaginal examination in and before labour. Aust N Z J Obstet Gynaecol 2019
  7. 362–6. [PubMed] [CrossRef] 7. Rizzo G, Aloisio F, Bacigalupi A, Mappa I, Słodki M, Makatsarya A, et al. Women’s compliance with ultrasound in labor: a prospective observational study. J Matern Fetal Neonatal Med 2021
  8. 1454–8. [PubMed] [CrossRef] 8. Westover T, Knuppel RA. Modern management of clinical chorioamnionitis. Infect Dis Obstet Gynecol 1995
  9. 123–32. [PubMed] [CrossRef] 9. Buchmann EJ, Libhaber E. Accuracy of cervical assessment in the active phase of labour. BJOG 2007
  10. 833–7. [PubMed] [CrossRef] 10. Dupuis O, Silveira R, Zentner A, Dittmar A, Gaucherand P, Cucherat M, et al. Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. Am J Obstet Gynecol 2005
  11. 868–74. [PubMed] [CrossRef] 11. Cuerva MJ, García-Casarrubios P, García-Calvo L, Gutiérrez- Simon M, Ordás P, Magdaleno F
  12. ITU-R12 Group. Use of intrapartum ultrasound in term pr