Anatomical variations detected during ultrasound-guided interscalene brachial plexus block and clinical implications

Sayfa
141–145
Yayın Tarihi
2022-10-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

We consider that prospective studies including more populations are needed to elucidate the effects ofthese variations on block parameters.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: Our aim was to evaluate the anatomic variations detected during ultrasound-guided interscalene brachial plexus block(US-ISB) and present their clinical implications.Materials and Methods: After the ethical approval for the study was obtained from the local ethics committee, the files and US recordsof patients who underwent US-ISB for anesthesia of the shoulder surgery were retrospectively analyzed.Results: Anatomical variations which were considered to affect the block technique were detected in 13 (11.8%) of 110 patients.
📊
Temel Bulgular & Veri:C5cervical root pierced the anterior scalene muscle (ASM) in 4.5%, and ventral rami of C5 and/or C6 were located in ASM in 3.6% ofpatients.
💡
Sonuç & Katkı:We consider that prospective studies including more populations are needed to elucidate the effects ofthese variations on block parameters.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: Our aim was to evaluate the anatomic variations detected during ultrasound-guided interscalene brachial plexus block(US-ISB) and present their clinical implications.Materials and Methods: After the ethical approval for the study was obtained from the local ethics committee, the files and US recordsof patients who underwent US-ISB for anesthesia of the shoulder surgery were retrospectively analyzed.Results: Anatomical variations which were considered to affect the block technique were detected in 13 (11.8%) of 110 patients. C5cervical root pierced the anterior scalene muscle (ASM) in 4.5%, and ventral rami of C5 and/or C6 were located in ASM in 3.6% ofpatients. There was a muscle bridge between C5 to C6 and C5 to C7 roots in 1.8% of the patients. The brachial plexus was locatedmedial to ASM and missing from interscalene groove in 1.8% of patients. In one case (C5 root was located in ASM), US-ISB resultedin incomplete brachial plexus anesthesia, and so general anesthesia (GA) was performed.Conclusion: Some of the brachial plexus variations in the interscalene area may be associated with further needle manipulation/redirection and block failure. We consider that prospective studies including more populations are needed to elucidate the effects ofthese variations on block parameters.

🔖

Bu Makaleye Atıf Yap

GOK, F., KORUCU, I. H., OZKAN, A., YILMAZ, R., KILICASLAN, A. (2022). Anatomical variations detected during ultrasound-guided interscalene brachial plexus block and clinical implications. Marmara Medical Journal, Cilt: 33 - Sayı: 3, 141–145. https://ajindex.com/articles/578395

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Harry WG, Bennett JD, Guha SC. Scalene muscles and the brachial plexus: anatomical variations and their clinical significance. Clin Anat 1997
  2. doi:10.1002/ (SICI)1098-2353(1997)10:4 [2] Cash CJ, Sardesai AM, Berman LH, et al. Spatial mapping of the brachial plexus using three-dimensional ultrasound. Br J Radiol 2005
  3. 78(936):1086-94. doi:10.1259/bjr/36348588 [3] Chin KJ, Niazi A, Chan V. Anomalous brachial plexus anatomy in the supraclavicular region detected by ultrasound. Anesth Analg 2008
  4. doi: 10.1213/ane.0b013e31817dc887 [4] Gutton C, Choquet O, Antonini F, Grossi P. Ultrasoundguided interscalene block: influence of anatomic variations in clinical practice (French). Ann Fr Anesth Reanim 2010
  5. doi: 10.1016/j.annfar.2010.07.013 [5] Kapral S, Greher M, Huber G, Willschke H, Kettner S, Kdolsky R, et al. Ultrasonographic guidance improves the success rate of interscalene brachial plexus blockade. Reg Anesth Pain Med 2008
  6. 253–8. doi: 10.1016/j.rapm.2007.10.011 [6] Kessler J, Gray AT. Sonography of scalene muscle anomalies for brachial plexus block. Reg Anesth Pain Med 2007
  7. doi: 10.1016/j.rapm.2006.09.011 [7] Feigl GC, Pixner T. Combination of variations of the interscalene gap as a pitfall for ultrasound-guided brachial plexus block. Reg Anesth Pain Med 2011
  8. 523–4. doi: 10.1097/AAP.0b013e31822897f1 [8] Abrahams MS, Panzer O, Atchabahian A, et al. Case Report: Limitation of Local Anesthetic Spread During UltrasoundGuided Interscalene Block. Description of an Anatomic Variant With Clinical Correlation. Reg Anesth Pain Med 2008
  9. doi:10.1016/j.rapm.2008.01.015 [9] Feigl GC, Litz RJ, Marhofer P. Anatomy of the brachial plexus and its implications for daily clinical practice: regional anesthesia is applied anatomy. Reg Anesth Pain Med.2020
  10. doi: 10.1136/rapm-2020-101435 [10] Feigl GC, Pixner T. The cleidoatlanticus muscle: a potential pitfall for the practice of ultrasound guided interscalene brachial plexus block. Surg Radiol Anat 2011
  11. 823–5. doi: 10.1007/s00276.011.0820-z [11] Kilicaslan A, Gürkan Y, Tekin M. A brachial plexus variation identified during ultrasound-guided interscalene block. Agri 2012
  12. doi: 10.5505/agri.2012.34966 [12] Koscielniak-Nielsen ZJ. Ultrasound-guided peripheral nerve blocks: what are the benefits? Acta Anaesthesiol Scand 2008
  13. doi: 10.1111/j.1399-6576.2008.01666.x [13] Leonhard V, Smith, R, Caldwell, G, Smith, HF. Anatomical variations in the